N932LR
Service difficulty reports · 190
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N932LR' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N932LR' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR WVER0821201500003Seat Track · corrodedLEFT SEAT TRACK, AT LBL 9, FS 881.00-FS 954.00 IS CORRODED BEYOND REPAIRABLE LIMITS OF REO 670-53-00-013, REV-J, DATED 2014/10/22. FABRICATED AND INSALLED SERVICEABLE SEAT TRACK IAW REO 670-53-00-343, AND AMM 53-00-49-000-801-A04.SDR WVER0821201593202Seat Track · corrodedRIGHT SEAT TRACK, AT RBL 9, FS 581 - 661+32, HAS MULTIPLE AREAS OF CORROSION BEYOND REPAIRABLE LIMITS REO 670-53-00-013, REV-J. FABRICATED AND INSTALLED NEW SERVICABLE SEAT TRACK IAW REO 670-53-00-343, AND AMM 53-00-49-000-801-A04SDR WVER0821201500001Drag Angle · crackedRT SIDE, VERTICAL STABILIZER, DRAG ANGLE, CRACKED 3" LONG. PERFORMED REPAIR IAW REO 690-55-31-004, REV-A, DATED 2009-03-04.SDR MASA2015071912245Battery Pack · inoperativeALL EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACKS.SDR MASA2015071112228Overheat Loop · looseRETURNED TO FIELD, DECLARED EMERGENCY DUE TO A LEFT BLEED DUCT WARNING. RESEATED & SAFETY MT138 & MT137.SDR MASA2015063012206Light · inoperativeDURING SCHEDULED MAINTENANCE, IT WAS FOUND THAT THE PASSENGER DOOR HAD 1 ILLUMINATION STRIP ON LOWER STEP THAT WAS DETERIORATED AFFECTING FUNCTIONALITY. R & R ILLUMINATION STRIP NO FURTHER DEFECTS.SDR MASA2015062212205Light · inoperativeDURING SCHEDULED MX IT WAS FOUND AT 8-10 RT SIDE EMERGENCY EXIT ILLLUMINATION STRIP WAS DETERIORATED AFFECTING FUNCTIONALITY. R & R ILLUMINATION STRIP, NO FURTHER DEFECTS.SDR MASA2015062312182Light · deterioratedDURING SCHEDULED MAINTENANCE, IT WAS FOUND AT ROW 13, RT SIDE, AFT EMERGENCY EXIT ILLUMINATION STRIP WAS DETERIORATED AFFECTING FUNCTIONALITY. R & R ILLUMINATION STRIP.SDR MASA2015053112118Flashlight · inoperativeFWD F/A FLASHLIGHT INOPERATIVE.SDR MASA2015040212995Light · inoperativeEMERGENCY CEILING LIGHT AT ROW 21 INOPERATIVE.SDR MASA2015030212934Bulb · inoperative14F EXIT SIGN, BULB INOPERATIVE. PLACED ON MEL.SDR MASA2015010112822Sign · inoperativeALLEY EMERGENCY EXIT SIGN, INOPERATIVE.SDR MASA2015010112821Sign · inoperativeROW 14, LT EMERGENCY SIGN INOPERATIVE.SDR MASA2014113012766Actuator · warning lightRT ENGINE FADEC CTN, IN FLIGHT SHUTDOWN. R & R SLAVE VG ACTUATOR AND BELLCRANK. BSI GOOD.SDR MASA2014110202715Fadec · warning messageRT FADEC CAUTION IN FLIGHT, RETURNED TO DEPARTURE AND A EMERGENCY WAS DECLARED. REPLACED RT FADEC.SDR MASA2014100902655Light · inoperativeFWD CEILING EMERGENCY FLOOD LIGHT INOPERATIVE.SDR MASA2014090802574Battery Pack · dischargedEMERGENCY EXIT LIGHTS WILL NOT ILLUMINATE DURING PRE-FLIGHT TEST. THE CREW CHARGED THE LIGHTING SYSTEM BATTERY PACKS WITH ACFT POWER.SDR MASA2014082702350Light · inoperativeROW 1 CEILING EMERGENCY FLOOD LIGHT INOPERATIVE.SDR MASA2014062202181Light · inoperativeCEILING LEVEL EMERGENCY FLOOD LIGHT INOPERATIVE.SDR MASA2014061302174Placard · wornFOUND PAX DOOR STEP OPEN PLACARD WORN & PEELING, R & R PLACARD.SDR MASA2014051831099Battery Pack · dischargedEMERGENCY LIGHTS WOULD NOT COME ON FOR PREFLIGHT TEST. CHARGED LIGHTS WITH APU POWER.SDR MASA2014042231044Bulb · inoperativeGALLEY FLOOR EMERGENCY EXIT LIGHT HAS ONE BULB INOPERATIVE.SDR MASA2014041831038Battery · inoperativeAFT F/A FLASHLIGHT NOT FLASHING. REPLACED BATTERY.SDR MASA2014022330945Light · inoperativeEMERGENCY CEILING FLOOD LIGHT, ROW 1, MAIN SERVICE DOOR OUT.SDR MASA2014011320857Bulb · inoperativeROW 13 AC FLOOR LEVEL EXIT SIGN 1 BULB OUT.SDR MASA2014010120832Battery Pack · inoperativeFWD F/A EMERGENCY FLASHLIGHT LED NOT BLINKING. REPLACED BATTERIES.SDR MASA2013102967918Battery Pack · inoperativeFWD F/A FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT BATTERIES.SDR MASA2013101416788Light · inoperativeROW 18, CEILING EMERGENCY FLOOD LIGHT INOPERATIVE.SDR MASA2013082977243Battery Pack · inoperativeFWD F/A FLASHLIGHT NO LED, R & R BATTERY.SDR MASA2013042152409Wire · damagedROW 1 CEILING FLOODLIGHT INOPERATIVE. REPAIRED WIRE AT CONNECTOR P355.SDR WVER20133259324Hinge · gougedPASSENGER DOOR HINGE ON FUSELAGE SIDE IS GOUGED FROM THE HINGE PIN RETAINING PIN BACKING OUT. DAMAGE IS APPROX 0.062" LONG X 0.062" WIDE X 0.039" DEEP. REPAIRED PASSENGER DOOR HINGE (FUSELAGE SIDE) IAW BOMBARDIER INC. REPAIR ENGINEERING ORDER (REO) 670-53-2SDR WVER20133269323Crossbeam · crackedFS 280.00 CROSSBEAM IS CRACKED JUST OUTBOARD OF LBL 9 AND RBL 9.SDR WVER20133259322Web · corrodedFS 280.00 RT LOWER WEB IS CORRODED BEYOND ALLOWABLE LIMITS AT RBL 9.0 EXTENDING OUT TO RBL 45.0. PERFORMED A MAJOR REPAIR BY CUTTING OUT DAMAGED MATERIAL AND INSTALLING REPAIR WEB IAW BOMBARDIER INC. REPAIR ENGINEERING ORDER (REO) 670-53-11-594 DATED 2011/04SDR WVER20133259321Web · corrodedFS 280.00 LEFT LOWER WEB IS CORRODED BEYOND ALLOWABLE LIMITS AT LBL 9.0 EXTENDING OUT TO LBL 45.0. PERFORMED A MAJOR REPAIR BY CUTTING OUT DAMAGED MATERIAL AND INSTALLING REPAIR WEB IAW BOMBARDIER INC. REPAIR ENGINEERING ORDER (REO) 670-53-11-594 DATED 2011/SDR MASA2012091025098Lamp · inoperativeROW 14 D/F EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED LAMP.SDR MASA2012080535014Light · inoperativeROW 11 CEILING LEVEL EMERGENCY EXIT LIGHT INOPERATIVE. THE LIGHT WAS PLACED ON MEL. RELAMPEDSDR MASA2012061634895Battery Pack · inoperativeCABIN EMERGENCY EXIT LIGHTS AND SIGNS INOPERATIVE. FLIGHT ATTENDANT SWITCH FOUND IN THE ON POSITION. MAINTENANCE CHARGED THE EMERGENCY EXIT LIGHTING BATTERY PACKS WITH AIRCRAFT POWER.SDR MASA2012061034867Battery · dischargedMEGAPHONE BATTERY DISCHARGED. MAINTENANCE INSPECTED AND FOUND VOLUME TOO LOW. MAINTENANCE ADJUSTED VOLUME. OPS GOOD.SDR MASA2012052834824Battery Pack · inoperativeFLIGHT ATTENDANT EMERGENCY LIGHT SWITCH FOUND IN THE "ON" POSITION AND EMERGENCY LIGHT BATTERY PACKS DEAD ON PRE FLIGHT INSPECTION. REMOVED AND REPLACED BATTERY PACK.SDR MASA2012042634732Battery · dischargedFWD F/A FLASHLIGHT RED LIGHT NOT FLASHING. REMOVED AND REPLACED BATTERY, OPS CHECK GOOD.SDR MASA2012032634615Placard · wornMED "OPEN" INTERIOR PLACARD WORN. R2 MED "OPEN" INTERIOR PLCD.SDR MASA2012022834487Light · inoperativeCEILING EMERGENCY LIGHT AT ROW 21 INOP. RELAMPED.SDR MASA2011122964317Flashlight · inoperativeFWD FA FLASHLIGHT INOPERATIVE. REMOVED AND REPLACED FLASHLIGHT.SDR MASA2011122764287Pbe · unserviceableAFT FA'S PBE VSI POPPED. REPLACED PBE.SDR MASA2011122664270Pbe · poppedFORWARD CABIN PBE VSI POPPED.SDR MASA2011121564223Light · inoperativeCEILING EMERGENCY EXIT LIGHT OUT AT ROW 6. RELAMPED EMERGENCY LIGHT.SDR MASA2011121364217Spring · defectivePAX DOOR VENT FLAP OPEN WITH DOOR CLOSED. GOING AOG FOR POSSIBLE SECOND SPRING P/N 601R317044-3 R2 SPRINGS.SDR MASA2011112864121Light · inoperativeAFT EMERGENCY CEILING LIGHT INOP. RELAMPED AFT EMER CEILING LIGHT.SDR MASA2011112564095Placard · damagedMAIN ENTRY DOOR EXIT SIGN DAMAGED. R2 MAIN ENTRY DOOR EXIT SIGN.SDR MASA2011112264083Battery Pack · failedNR 2 EMERGENCY LIGHT BATTERY FAILED. MX R2 BATTERY PACK.
Back to N932LR