N946FD
Service difficulty reports · 176
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N946FD' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N946FD' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201012154683Fitting · corrodedAFT CARGO COMPT RT CARGO NET TIE-DOWN FITTING AT STA 1360 FOUND WITH CORROSION. CORRODED RT CARGO NET TIE-DOWN FITTING AT STA 1360. R & R IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012154682Fitting · crackedAFT CARGO COMPT LT CARGO NET TIE-DOWN FITTING AT STA 1380 FOUND CRACKED OFF. CRACKED CARGO NET TIE-DOWN FITTING AT STA 1380. R & R IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012154681Floor Support · corrodedFWD CARGO COMPT FLOOR DECK PLATE SUPPORT AT STA 640- STA 660, RBL 7.55. FOUND WITH CORROSION. CORRODED SUPPORT FROM STA 640 TO STA 660, RBL 7.55. R & R IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012154680Skin · crackedAFTER REMOVAL OF LT INBD AFT FLAP, FOUND FAIRING WEDGE ASSY SPLICE TEE CRACKED AT MFSTA 223.86. CRACKED LT WING INBD AFT FLAP FAIRING WEDGE SPLICE TEE IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012154679Shear Tie · crackedREF EO F-5710-7-5002, PT 4, RT WING PANEL SUPPORT BEAM CLIP CRACKED AT IRSS 164.95. CRACKED RT WING PANEL SUPPORT BEAM CLIP AT IRSS 164.95. R & R IAW EO F-5710-7-5002 PT 4 (WING T/E FIXED UPPER PANEL SUPPORT BEAM CLIP INSP AND REPLACEMENT). REPAIR IS CLASSIFSDR FDEA201012154678Beam · corrodedLT LOWER AFT WTB FAIRING STRUCTURE BEAM ASSY CHORD AT STA 1037.67- STA 1060, LBL 6 FOUND CORRODED. CORRODED LT AFT WTB FAIRING STRUCTURE RAIL BETWEEN STA 1037.67 AND STA 1060, LBL 6. R & R IAW SRM 51-40-02 REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012154677Access Panel · corrodedNR3 BULK CARGO DOOR LOWER FWD CORNER LINKAGE ACCESS COVER HAS CORROSION ON INTERIOR SIDE. NR3 CARGO DOOR FWD CORNER LINKAGE ACCESS COVER R & R IAW SRM 51-40-02 REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012144676Support Angle · crackedAFT CARGO COMPT LT SIDEWALL PANEL SUPPORT ANGLE PLATE AT STA 1310 - STA 1360 FOUND CRACKED AND WITH MULTIPLE CHAFFED MARKS. CRACKED ANGLE PLATE BETWEEN STA 1310 AND STA 1360. R & R IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012144675Reveal · crackedAFT CARGO COMPT RT FWD SIDEWALL PANEL REVEAL PLATE AT STA 1380 FOUND CRACKED. CRACKED REVEAL PLATE AT STA 1380 R & R IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012144674Floor Support · corrodedFWD CARGO COMPT FLOOR DECK PLATE SUPPORT AT STA 640- STA 660 RBL 16.10 FOUND WITH BULGE CORRODED DECK PLATE SUPPORT FROM STA 640 TO STA 660, RBL 16.10. R & R IAW SRM 51-40-02 REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012144673Floor Support · corrodedAFT CARGO COMPT FLOOR DECK PLATE SUPPORT AT STA 1460-STA 1480, LBL 10.45 FOUND WITH CORROSION. CORRODED SUPPORT AT STA 1460 -STA 1480, LBL 10.45. R & R IAW SRM 51-40-02 REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012134658Seat Track · corrodedCABIN STN 783, RBL 45 FOUND CORROSION ON SEAT TRACK. CORRODED SEAT TRACK AT STN 783, RBL 45. R & R IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012134657Floorbeam · corrodedFLOORBEAM AT STN 377.7 LBL 60 TO LBL 66, MINOR SURFACE CORROSION ON UPPER CHORD. CORRODED FLOORBEAM AT STN 377.7, LBL 60 TO LBL 66. R & R IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012134656Floorbeam · corrodedCABIN FLOORBEAM AT STN 1640, RBL 51 TO RBL 60 HAS SURFACE CORROSION. CORRODED FLOORBEAM AT STN 1640, RBL 51 TO RBL 60. R & R IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012134655Floorbeam · corrodedFLOORBEAM AT STN 720 RBL 48 TO RBL 56 HAS SURFACE CORROSION ON BEAM CAP. CORRODED FLOORBEAM AT STN 720, RBL 48 TO RBL 56. R & R IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012134654Sill · corrodedSTN 720 TO STN 740, DOOR 2R SILL STRUCTURE HAS SURFACE CORROSION. CORRODED R2 DOOR SILL SUPPORTS R & R IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012134653Shear Tie · crackedNR2 PYLON STRUT, WHILE INSTALLING SKIN PANEL AT PP STA 185.35 (BATH TUB FITTING AREA), RT SIDE NOTICED CRACK IN VERTICAL SHEAR CLIP BETWEEN LOWER 2 FASTENER HOLES. CRACKED SHEAR CLIP ON NR 2 PYLON STRUT. R & R IAW SRM 51-40-02 REV101. REPAIR IS CLASSIFIED ASDR FDEA201012134652Support Bracket · corrodedDOOR 4L SILL PLATE SUPPORT BRACKETS CORRODED. CORRODED L4 DOOR SILL PLATE SUPPORT BRACKETS R & R IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201012134651Plate · corrodedAFT CABIN FLOOR PLATE AT STA 1680, RBL 24 TO RBL 30 HAS SURFACE CORROSION AROUND SCREW HOLES. REPAIR ON AFT CABIN FLOOR PLATE AT STA 1680, RBL 24 TO RBL 30 CARRIED OUT IAW SRM 53-60-51, REPAIR 2 ALTERNATIVE 1 REV 101. REPAIR IS CLASSIFIED AS MAJOR.SDR FDEA201012064603Frame · corrodedLT ELEVATOR HAS CORROSION OTBD FWD EDGE OF LOWER SIDE OF CONDUCTIVE FRAME. CORRODED CONDUCTIVE FRAME ON LT ELEVATOR. R & R IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA201012024535Support Bracket · crackedPNEUMATIC DUCT SUPPORT BRACKET IN HORIZ STAB COMPT AT STA 1787.45 FOUND CRACKED AND BROKEN. CRACKED SUPPORT BRACKET AT STA 1787.45 R & R IAW SRM 51-40-02 REV 101. REPAIR IS CLASSIFIED AS MINOR IAWPER GMM 6-2-100.SDR FDEA201012024534Retainer · corrodedRT WING BOTTOM, RT MLG DOOR BULB SEAL RETAINER IS CORRODED. CORRODED SEAL RETAINER R & R IAW SRM SRM 51-40-02 REV 101. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-00.SDR FDEA201011224454Fairing · crackedRT WING FLAP FAIRING NR 672HB FWD EDGE ALUMINIUM HAS CRACK AT 5.00 POS CRACKED RT WING FLAP FAIRING NR 672HB R & R IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA201011224453Intercostal · crackedE/E COMPT LT INTERCOSTAL ASSY AT STA 440- STA 460 S24L FOUND CRACKED. CRACKED INTERCOSTAL R & R UNDER MAE PTF MOD WC 118150066FL1R02 (SUPPORT INTSL E1- E6 ELEX EQUIP CTR STA 418-460), REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA201011104315Rib · corrodedLT WING: W STA 817.5" OTBD AILERON RIB HAS CORROSION AT BONDING STRAP ATTACHMENT. CORRODED LT AILERON HINGE SUPPORT RIB AT WS 817.5. R & R IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201011104314Rib · corrodedRT WING REAR SPAR STA 820 RIB FOR OTBD AILERON HINGE, OTBD SIDE OF RIB HAS CORROSION AT ONLY NUT PLATE LOCATION. CORRODED RT AILERON HINGE SUPPORT RIB AT WS 817.5. R & R IAW SRM 51-40-02, REV 101. REPAIR IS CLASSIFIED AS MINOR.
Back to N946FD