N947LR
Service difficulty reports · 55
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N947LR' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N947LR' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MASA2023111600140Unknown · unknownROW 14 CEILING EMER FLOOD LIGHT INOP- RESET ACFT PWR, OPS CHECK GOOD, NO DEFECTSSDR MASA2023091500019Unknown · unknownROW 3 MID LVL EXIT SIGN HALF ILLUMIN- SECURED CONNECTOR TO LIGHT ASSYSDR MASA20230828004Frame · crackedFRAME AT 333 STR O IS CRACKED THROUGH RIVET HOLE AND STARTING INTO ANGLE RADIUS. INSTALLED REPAIR ANGLES AND DOUBLER IAW REO 690-53-21-1654SDR MASA2023062100081Bulb · burned outROW 7 EMERG LIGHT INOP (CENTER OF CABIN)
RELAMP OPS CHECK GOOD.SDR MASA2023051330077Unknown · unknownMLG BAY OVERHEAT WARNING CURRENTLY OUT OF SERVICE, ITEM WAS ON MEL, PIC STATED HE DID NOT FOLLOW THE DIRECTIONS OF THE MEL AND DID NOT LEAVE HIS GEAR EXTENDED FOR AT LEAST 10 MINUTES BEFORE RETRACTING THE GEAR INTO THE WHEEL WELL. RECEIVED A MLG OVERHEAT AND HSDR MASA2023042100063Unknown · unknownEMERGENCY LIGHTS INOP- MX CHARGED THE EMERG LIGHT BATTERIESSDR MASA2022072300192None · noneROW 17 CEILING EMERGENCY FLOOD LIGHT INOP. PLACED ON DEFERRAL.SDR MASA2022020800036Unknown · odorSMOKE SMELL IN CABINSDR MASA2021071100159Warning Message · false activationLEFT BLEED DUCT WARNING. PERFORMED OPS CHECK OF BLEED SYS-OPS CHECK NORMALSDR MASA2021051000109Bulb · inoperativeFLOOR LEVEL EMER LTS INOP AT PAX DR 2 BULBS. PLACED ON MEL.SDR MASA2021051000108Bulb · inoperativeROW 12 LH EMERGENCY EXIT SIGN 1 BULB INOP- PLACED ON MELSDR MASA2021051000107Bulb · inoperativeROW 12 RH EMERGENCY EXIT SIGN 1 BULB INOP- PLACED ON MELSDR MASA2020070810120Light · inoperativeGALLEY EMER LIGHT BULBS OUT. RELAMPED.SDR MASA2020041710159Battery · dischargedCABIN EMERGENCY LIGHTS WONT STAY ON. CHARGED BATTERIESSDR MASA2020020100041Battery Pack · dischargedEMER LTS ARE DEAD-FLT DK SWITCH LEFT ON
CHARGED EMERGENCY BATTERIESSDR MASA2019042911831A/C Pack · failedSMOKE IN COCKPIT W LT PACK AUTO FAIL CAUTION EMERG DECLARED
PLACED LT PACK ON MELSDR MASA2018071713416Sign · inoperativeLT AND RT OVERWING EXIT SIGNS INOP. PLACED ON MEL.SDR MASA2018053113280Battery Pack · dischargedNUMEROUS INTERIOR EMERGENCY LIGHTS WERE INOPERATIVE. ALLOWED BATTERIES TO CHARGE AND THE LIGHTS TESTED NORMALLY.SDR MASA2018051603204Bulb · inoperativeROW 8 CEILING EMERGENCY FLOOD LIGHT INOPERATIVE. REPLACED THE BULB.SDR MASA2018032313083Battery Pack · dischargedROWS 3, 12, 13 EMERG EXIT SIGNS INOP. REPLACED NR 3 BATTERY PACK.SDR MASA2018021812991Light · inoperativeNUMEROUS INTERIOR EMERGENCY LIGHTS INOPERATIVE.SDR MASA2017122612860Battery Pack · inoperativeROW 12 FLOOR LIGHTED EXIT SIGN INOPERATIVE. CHARGED THE BATTERIES.SDR MASA2017122612859Battery Pack · dischargedMID CABIN EMERGENCY EXIT SIGN INOPERATIVE. CHARGED THE BATTERIES.SDR MASA2017112612790Light · inoperativeEMERG FLOOD LIGHT ROW 5 INOP. RELAMPED.SDR MASA2017100112679Battery · dischargedAFT CEILING EMER LIGHTS INOP. RECHARGED BATTERIES.SDR MASA2017070612443Light · inoperativeROW 20 EMERGENCY FLOODLIGHT INOP. REPLACED BULB.SDR MASA2017050712774Light · inoperativeROW 12F LOWER EMERG EXIT SIGN ONE BULB INOP. PLACED ON MEL.SDR MASA2017012412828Light · inoperativeCEILING EMER FLOOD LIGHT ROW 17 INOP. REPLACED BULB.SDR MASA2016101212449Battery Pack · inoperative4D BULKHEAD EXIT SIGN WILL NOT ILLUMINATE. REPLACED BATTERY PACKSDR MASA2016100912441Battery Pack · dischargedROW 4A EMERGENCY EXIT SIGN FACING AFT INOPERATIVE. ALLOWED BATTERY TO CHARGESDR MASA2016100812440Knob · detachedMEGAPHONE VOLUMN CONTROL KNOB DETACHED. MX SECURED THE KNOB.SDR MASA2016008012887Light · inoperativeROW 17 EMERGENCY LGHT INOPERATIVE.SDR WVER2016062194706Hinge · chafedPASSENGER DOOR PIANO HINGE, AIRFRAME SIDE, IS GOUGED ON AFT LUG LANDING FROM CONTACT WITH ROLL PIN.SDR WVER2016062094705Fitting · not reportedPERFORMED A MAJOR REPAIR TO THE HORIZONTAL STABILIZER PIVOT FITTING, JOINT BY INCORPORATING SB 670BA-55-013, REV F, DATED MAY 27/2015 AND 670BA-55-012, REV E, DATED MAY 25/2015.SDR WVER2016061794701Elevator · damagedLEFT ELEVATOR HAS SMALL DAMAGE MARK ON T/E BETWEEN RIB 10 AND 11.SDR WVER20160611003Bulkhead Web · corrodedLEFT AND RIGHT FS 280.00, LOWER BULKHEAD WEBS, FOUND TO BE CORRODED. REPAIRED LT & RT FS 280.00 LOWER BULKHEAD WEB'S IAW REO 670-53-11-594, REV-A, DATED 2015/06/26.SDR WVER2016061994704Hinge Fitting · gougedLEFT INBD HINGE BOX FITTING ON INBD FLAP IS GOUGED IN MULTIPLE AREAS.SDR MASA2016020112732Battery Pack · inoperativeAFT F/O FLASHLIGHT INOPERATIVE. REPLACED BATTERY.SDR MASA2015102312494Bulb · inoperativeONE LAMP INOPERATIVE EXIT LT ROW 13.SDR MASA2015100212441Bulb · inoperativeEXIT SIGN 13F, 1 BULB INOPERATIVE.SDR MASA2015082112326Light · inoperativeCEILING EMERGENCY FLOOD LIGHT INOPERATIVE, ROW 8.SDR MASA2015050712058Bulb · inoperativeEMERGENCY FLOOD LIGHT FWD ROW 1.SDR MASA2015050712055Bulb · inoperativeROW 20 CEILING FLOOD LIGHT INOPERATIVE.SDR MASA2015042812030Light · inoperativeEMERGENCY FLOOD LIGHT ROW 14 INOPERATIVE.SDR MASA2015032412974Flashlight · inoperativeAFT F/A FLASHLIGHT INOPERATIVE.SDR MASA2015010612836Flashlight · inoperativeFWD F/A FLASHLIGHT NOT CHARGING.SDR MASA2014110502725Flashlight · inoperativeFWD F/A FLASHLIGHT INOPERATIVE.SDR MASA2014100802654Bulb · inoperativeBULB INOPERATIVE EMERGENCY EXIT SIGN, ROW 13 RT SIDE. MAINTENANCE REPLACED THE BULB.SDR MASA2014100802653Bulb · inoperativeBULB INOPERATIVE AT EMERGENCY EXIT SIGN, ROW 12 RT SIDE. MAINTENANCE REPLACED THE BULB.SDR MASA2014092902631Light · inoperativeEXTERIOR FWD OVERWING EXIT LIGHT INOPERATIVE.