N957SW
Service difficulty reports · 264
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N957SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N957SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA200617506Plate · corrodedRT ENGINE PYLON AFT END BONDING PLATES 3 HAVE CORROSION 2 ON TOP AND 1 ON THE BOTTOM, DISCOVERED DURING C-CHECK INSPECTION. REPLACED 2 TOP AND 1 BOTTOM RT ENGINE PYLON AFT END BONDING PLATE 3 WITH 2024T-3X .016" PO NR 71462, IAW DRAWING NR 601-37012 AND CRJ20SDR SWIA200616069Actuator · malfunctionedSPOILERON FAULT ON TAXI OUT. REPLACED THE PCU-FLIGHT IB SPOILERON ACTUATOR IAW AMM 27-62-01. OPERATIONAL CHECK GOOD.SDR SWIA200516050Control Unit · malfunctionedTAXI OUT GOT "SPOILERON FAULT". REPLACED NR 2 SECU AND OPERATIONAL CHECK GOOD PER AMM 27-61-05.SDR SWIA200515641Lamp · burned outROW 10 CEILING EMERGENCY LIGHT INOP. RELAMPED ROW 10 EMERGENCY LIGHT, OPERATIONAL CHECK GOOD.SDR SWIA200515068Bulb · burned outLEFT FORWARD OVERWING EMERGENCY LIGHT INOP. REPLACED BULB OPERATIONAL CHECK GOOD.SDR SWIA200515029Control Unit · malfunctionedSTAB CH1 INOP MSG AFTER LANDING. REPLACED MOTOR CONTROL UNIT IAW CRJ AMM 27-42-05. OPERATIONAL CHECK GOOD.SDR SWIA200514898Control Unit · malfunctionedMDC REPORTS HSTCU HAS POSITION FAIL AND ADC MACH NUMBER FAIL. REPLACED HSTCU WITH SERVICEABLE UNIT. OPERATIONAL CHECK GOOD.SDR SWIA200514799Attach Fitting · crackedATTACH CLIP AT FS 589.00 CRACKED. ITEM FOUND AT C-CHECK INSPECTION. REMOVED ATTACH CLIP ANGLE IAW CRJ SRM 51-40-11 PARA 4, 51-42-21 AND 51-41-02. UPON REMOVAL OF THE ANGLE, NO CRACK FOUND. REINSTALLED ATTACH CLIP ANGLE IAW CRJ SRM 51-40-11 PARA 4, 51-42-2SDR SWIA200514798Floorbeam · crackedRT FLOORBEAM ANGLE AT FS 621.00 IS CRACKED. ITEM FOUND AT C-CHECK INSPECTION. CRACKED ANGLE REPAIRED IAW REO 601R-53-61-117 REV B.SDR SWIA200514797Floorbeam · crackedLT FLOORBEAM ANGLE AT FS 621.00 IS CRACKED. ITEM FOUND AT C-CHECK INSPECTION. CRACKED ANGLE REPAIRED IAW REO 601R-53-61-117 REV B.SDR SWIA200514372Light · inoperativeFLOOR LEVEL EMERGENCY LIGHTS BETWEEN ROWS 2-5 INOP. INSTALLED SERVICEABLE GREEN FLOOR LEVEL LIGHTING STRIP AT ROW 2C IAW CRJ 200 MM 33-51-00, OPERATIONAL CHECK GOOD.SDR SWIA200514343Transducer · malfunctionedNO FULL LEFT RUDDER INDICATION ON EICAS. REMOVED AND REPLACED RUDDER RCS TRANSDUCER, OPERATIONAL CHECK GOOD IAW 22-24-05.SDR SWIA200414280Lamp · burned outCEILING EMERGENCY FLOODLIGHT AT ROW 10 IS INOPERATIVE. RELAMPED EMERGENCY FLOODLIGHT AT ROW 10 . OPERATIONAL CHECK GOOD.SDR SWIA200413061Door · lack of lubeCABIN SERVICE DOOR DIFFICULT TO OPEN FROM INSIDE AND OUTSIDE. LUBRICATED SERVICE DOOR SEAL. OPS CHECKED GOOD.
Back to N957SW