N958WN
Service difficulty reports · 158
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N958WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N958WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023051825022Shield · corrodedMULTIPLE AREA OF CORROSION ON AFT CARGO BAY AFT DOOR SHIELD AT RBL 21 BS 847-867<[01] REMOVED CORROSION FROM 6 SPOTS ON PART 146A8172Y10. THE DEEPEST SPOT IS 0.50 X 0.50 DEPTH 0.005. ORDINAL THICKNESS IS .040. PART HAS NO LIMITS FOR DAMAGE(OUT OF LIMITS). REPASDR SWAA2023051724720Floor Panel · pulledAFT FLOOR PANEL 242SF UPPER FACESHEET HAS AREAS OF PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 242SF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 6 TABLE 6. PULLED STRANDS OF FIBERGLASS AT DISCREPANT LOCATION EXCEED ALLOWABLE DAMAGE LIMITS AND REQUIRE REPAIR IAW SRM SDR SWAA2023051724731Floor Panel · pulledAFT FLOOR PANEL 242TF UPPER FACESHEET HAS AREAS OF PULLED STRANDS.<[01] NEW FLOOR PANEL WAS FABRICATED IAW EA 23-153-01187-WIP1 & EA 23-153-01187. VERIFIED ALL STEPS COMPLETED WITH NO DEVIATIONS.<BR><BR>JOB COMPLETE.;[02] VERIFIED CORRECTIVE ACTION ITEM 1 COMPSDR SWAA2023051724732Floor Panel · brokenAFT PANEL 242XF LOWER SKIN IS BROKEN. (MARKED)<[01] IDENTIFIED FLOOR PANEL 242XF MATERIAL IAW SRM 53-00-50-0I-1 FIG 6; TABLE 6 AND BOING DWG 147A5810-11.<BR><BR>FOUND DAMAGE AT 2EA LOCATIONS ON LOWER SURFACE; BOTH AREAS ARE OUT OF ALLOWABLE DAMAGE LIMITS IAW SSDR SWAA2023051724721Floor Panel · pulledAFT PANEL 241XF UPPER FACESHEET HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] NEW FLOOR PANEL WAS FABRICATED IAW EA 23-153-01174-WIP1 AND EA 23-153-01174. VERIFIED ALL STEPS COMPLETE.;[02] VERIFIED CORRECTIVE ACTION ITEM 1 COMPLETE.SDR SWAA2023051724723Floor Panel · pulledAFT PANEL 241ABF UPPER FACESHEET HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] VERIFIED COMPLETION OF PANEL 241ABF FABRICATION IAW EA 23-153-01175;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2023051724724Floor Panel · pulledAFT PANEL 241ADF UPPER FACESHEET HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] NEW PANEL WAS FABRICATED IAW EA 23-153-01177-WIP1 AND EA 23-153-01177. ALL STEPS COMPLETED WITH NO DEVIATIONS. <BR><BR> JOB COMPLETE.;[02] VERIFIED CORRECTIVE ACTION 1;[03] VERIFIED CUSDR SWAA2023051724734Floor Panel · pulledFWD PANEL 221BF UPPER FACESHEET HAS AN AREA OF PULLED STRANDS.<[01] FLOOR PANEL 221BF WAS REPLACED WITH A SERVICEABLE FLOOR PANEL ON FAULT TTG8Q00KBJAJ.;[02] PANEL REPLACED. JOB COMPLETESDR SWAA2023051725012Panel · brokenFWD. R/H BRACKET BROKEN AT LWR. FAIRING WING CENTER SECTION PANEL 192E<[01] VERIFIED APPLICABILITY FOR ALLOWABLE DAMAGE IAW SRM 51-10-02;[02] FOUND PART TO HAVE NO SRM LIMITS AND SO PART IS REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9.;[03] REMOVED FWD R/SDR SWAA2023051725011Threshold · corrodedMULTIPLES AREA OF CORROSION ON AFT CARGO BAY THRESHOLD AT BS 787+8-847 RBL 27.5.<[01] VERIFY APPLICABILITY OF SRM 53-60-15-1A-1<BR><BR>MEASURMENT UPDATE;[02] FIXED REMAINING THICKNES FROM 0.035 TO 0.033;[03] REMOVED CORROSION FROM AFT CARGO THRESHOLD WEB BS787SDR SWAA2023051725024Sidewall Support · corrodedMULTIPLE AREA OF CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727+4 TO BS 767.<[01] VERIFIED SRM 53-00-53-1A-2 TO BE APPLICABLE;[02] REMOVED CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 727+4 TO BS 767; DEEPEST AREA OF DASDR SWAA2023051725013Sidewall Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 22.5 BS 867+11.75; BS 867+15.<[01] VERIFIED APPLICABILITY OF SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2 AND UPDATED MEASUREMENT TABLE.;[02] TOOL USED DEPTH GAGE ID ATS2472; S/N: UNKNOW; DUE DATE: 12/31/23.;SDR SWAA2023051725026Sidewall Support · corrodedMULTIPLE AREA OF CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 727B TO BS 727E+9.<[01] SRM 53-00-53-1A-2 FOUND TO BE APPLICABLE<BR>UPDATED MEASUREMENT TABLE;[02] SRM 53-00-53-1A-2 FOUND TO BE APPLICABLE<BR>UPDATED MEASUREMENT TABLE;[03] REMSDR SWAA2023051725030Tie Down · corrodedAFT CARGO BAY - TRACK-TIE DOWN HAS A CORROSION BS 867 RBL 13.5<[01] REMOVED CORROSION AT ACB TRACK-TIE DOWN RBL 13.75; BS 867 IN L=2' X W=1' X D=0.030'' FROM ORIGINAL TICKNESS OF 0.080' FOUND TO BE OUT OF LIMITS IAW SRM 51-10-02 AND SRM 53-00-53-1A-2.<BR>USED SDR SWAA2023051724722Floor Panel · pulledAFT FLOOR PANEL 241YF UPPER FACESHEET HAS AN AREA OF PULLED STRANDS.<OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PAR. 4. E. & 4. F.PANEL UPPER SURFACE IS REPAIRABLE IAW SRM 53-00-50-2R-1 AS DIRECTED <BR>BY SRM 53-00-50-2R-0 PAR. 2. A. TABLE 201.REMOVESDR SWAA2023051725321Floor Panel · pulledAFT PANEL 241ZF UPPER FACESHEET HAS AREAS OF PLLED STRANDS.<OUT OF ALLOWABLE DAMAGE LIMITS IAW <BR>SRM 53-00-50-1A-1 PAR. 4. F.PANEL UPPER FACESHEET IS REPAIRABLE IAW SRM 53-00-50-2R-1 AS <BR>DIRECTED BY SRM 53-00-50-2R-0 PAR. 2. A. TABLE 201.<BR><BR>REMOVED (SDR SWAA2023051724735Floor Panel · pulledFWD PANEL 221CF UPPER FACESHEET HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] PART/MATERIAL IDENTIFIED PER SRM 53-00-50-0I-1 FIG 2 TABLE 2 SECTION 41<BR>UPPER SURFACE STRAND DAMAGE EXCEEDS THE ALLOWABLE DAMAGE LIMITS PER SRM 53-00-50-1A-1 PARA 4. B.<BR>REPAIR TO SDR SWAA2023051824709Structure · corrodedCORROSION ON PASSENGER CABIN UPPER CHORD AT BS 706 WL 208 RBL 63.<OUT OF LIMITS PER SRM 53-40-13-1A-1 FIG. 103 DETAIL F.;[08] DURING MAINTENANCE; CORROSION WAS FOUND COMMON TO EXISTING PASSENGER CABIN UPPER CHORD AND REMOVED CORROSION AT RBL63; WL 208<BR>BS685SDR SWAA2023051724496Scuff Plate · crackedFWD CARGO BAY FWD SCUFF PLATE CRACKED<[01] WELDED CRACKS ON FWD CARGO BAY FWD CORNER SCUFF PLATE USING ER4043 FILLER ROD LOT NUMBER 1131216 PER SRM 53-30-15-2R-1 PARA 4.B. (2) AND (4).<BR>EQUIP USED: WELDING MACHINE E10583 DUE 01/2024;[02] VERIFIED CORRECTIVE SDR SWAA2023051724711Floor Support · crackedCRACK ON PASSENGER CABIN FLOOR SUPPORT AT BS 540 LBL 2 WL 208.<[01] REMOVED PANEL BREAK ASSY LOCATED AT B.S. 540; LBL 2; WL 208 PER SRM 51-10-02-0G-0 PARA: 4.C.(3) AND SRM 51-40-02-0G-0;[02] LOCATED AND DRILLED PANEL BREAK ASSY PER SRM 51-40-05-0G-0; SRM 51-40SDR SWAA2023051724139Floor Panel · pulledPASSENGER CABIN FLOOR PANEL 231XF UPPER SKIN HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] IDENTIFIED 231XF PANEL IAW SRM 53-00-50-0I-1 PARA FIGURE 4; TABLE 4<BR><BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F<BR><BR>WILL PERFORM REPSDR SWAA2023051724135Floor Panel · pulledPASSENGER CABIN FLOOR PANEL 241AF UPPER SKIN HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] PART/MATERIAL IDENTIFIED PER SRM 53-00-50-0I-1 FIGURE 4 TABLE 4 SECTION 44. <BR>CABIN FLOOR UPPER SURFACE EXCEEDS ALLOWABLE LIMITS AS GIVEN IN SRM 53-00-50-1A-1 PARA 4 CONDSDR SWAA2023051724136Floor Panel · pulledPASSENGER CABIN FLOOR PANEL 241BF UPPER SKIN HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF ALL THE DAMAGE; DECIDED TO FABRICATE A NEW FLOOR PANEL FROM BMS4-17 TYPE VI LOT NUMBER 1522265-1 USING BMS5-107 CLASS 1 RESIN LOT NUMBER AK2KP8383K-1 WSDR SWAA2023051724137Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 242AF UPPER SKIN OF AFT O/B CORNER IS DELAMINATED FROM CORE.<[01] DUE TO THE EXTENT OF ALL THE DAMAGE; DECIDED TO FABRICATE A NEW FLOOR PANEL FROM BMS4-17 TYPE VI LOT NUMBER 1522265-1 USING BMS5-107 CLASS 1 RESIN LOT NUMBER AK2KP838SDR SWAA2023051724140Floor Panel · pulledPASSENGER CABIN FLOOR PANEL 242DF UPPER SKIN HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 242DF IAW SRM 53-00-50-0I-1 FIGURE 4 TABLE 4<BR><BR>DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PAR.4 B<BR><BR>DUE TO EXTENT OF DAMASDR SWAA2023051823385Panel · crackedRT WING L/E PANEL 621CB FWD O/B CORNER IS CRACKED<OUT OF ALLOWABLE LIMITS IAW SRM 57-41-01-1A-1 PARA 4.A(5).REMOVED INNER SURFACE DAMAGED PLIES AND CLEANED REPAIR AREA FABRICATED REPAIR PLIES FROM BMS 5-129 TY2 GR05 LOT#1521552-3; BMS 8-79 CL3 ST120 LOT#152013SDR SWAA2023051723561Bulkhead · crackedCRACKED LOWER L/H COMPOSITE BULKHEAD AT BS663 LBL34 WL149.<OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 57-10-10-1A-2 PAR 4.D (1).<BR>A PERMANENT REPAIR WILL BE ACCOMPLISHED IAW SRM 51-70-04-2R-10 AS DIRECTED PER SRM 57-10-10-2R-2 PAR 1.C.;[02] DETERMINED EXTENT OF SDR SWAA2023051723127Cover · out of adjustRH EMERGENCY EXIT LIGHT COVER IS LOOSE.(MARKED).<[01] TTGTENED RH EMERGENCY EXIT LIGHT COVER PER MM 33-51-01-960-802;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2022053112078Battery Pack · failedEMERGENCY EXIT LIGHT BATTERY PACK (M1673) FAILS TO TAKE CHARGE / [01] SIGNING AND CERTIFYING FOR AAR EMPLOYEE #28971. REPLACE EMERGENCY LIGHT BATTERY PACK (M1673) EMERGENCY LIGHTS OPS CHECK GOOD IAW AMM 33-51-06-960-805;[02] SIGNING AND CERTIFYING FOR AAR EMPLSDR SWAA2022053109211Light · detachedPHOTOLUMINESCENT FLOOR LIGHT STRIP AT SEAT ROW 8ABC IS DISBONDED / [01] REMOVED AND REINSTALLED PHOTOLUMINESCENT STRIP CORRECTLY AT SEAT ROW 8ABC I/A/W AMM 33-51-15-000-802 AND 33-51-15-400-802.SDR SWAA2022040489544None · crackedELECTRICAL AND ELECTRONICS COMPARTMENT CENTER INTERCOSTAL BETWEEN BS344 AND BS360 IS CRACKED AT THE FASTENER HOLES / [01] REMOVED AND REPLACED INTERCOSTAL PER SRM 51-10-02.SDR SWAA2022040489531Panel · cracked-RIGHT WTB PNL 191AR TO 191FR VERTICAL SUPPORT CRACKED JUST I\B OF LANDING LIGHT. / [01] REMOVED AND REPLACED VERTICAL SUPPORT AT RIGHT WTB PNL 191AR TO 191FR JUST I/B OF LANDING LIGHT PER SRM 51-40-02SDR SWAA2022040489366Battery Pack · failedFOUND TWO EMERGENCY LIGHTING BATTERY PACKS FAILED CAPACITY TEST. / [01] REMOVED & REPLACED TWO EMERGENCY LIGHTING BATTERY PACKS (M01668 & M01669) PER AMM 33-51-06 AND DWG # 33500005.SDR SWAA2022040490866Battery Pack · failedFOUND TWO EMERGENCY LIGHTING BATTERY PACKS FAILED CAPACITY TEST. / [01] REMOVED & REPLACED TWO EMERGENCY LIGHTING BATTERY PACKS (M01668 & M01669) PER AMM 33-51-06 AND DWG # 33500005.SDR SWAA2021083010923Access Panel · crackedRIGHT WING LEADING EDGE PANEL 621YB CRACKED ; PANEL CRACKED 2.2 INCHES ALONG THE INBD FWD LEADING EDGE / [01] REMOVED AND REPLACED RIGHT WING L/E ACCESS PANEL 621YB REF AMM 57-41-02SDR SWAA2021042363569Floorbeam · crackedCRACKED FLOOR SUPPORT AT B.S. 540; B.L. 0 - L.B.L. 24.5; W.L. 208.1. / REMOVED & REPLACED FLOOR SUPPORT AT B.S. 540; B.L 0 - L.B.L 24.5; W.L. 208.1. PER SRM 51-40-02 AND DWG # 143A5240 57600U 14APR21SDR SWAA2021042363570Floorbeam · crackedCRACKED FLOOR SUPPORT AT B.S. 540; B.L. 0 - R.B.L. 24.5; W.L. 208.1. / REMOVED & REPLACED FLOOR SUPPORT AT B.S. 540; B.L. 0 - R.B.L. 24.5; W.L. 208.1; PER SRM 51-40-02 AND DWG # 143A5240 57600U 14APR21SDR SWAA2021042363547Seat Track · corrodedCORROSSION AND ABRASION ON SEAT TRACK BS 540-727B; LBL 45; WL 208 / REMOVED CORROSION ON SEAT TRACK BS 540-727B LBL 45 WL 208. AT BS 697 1' X .5' X .026 (CROWN) FOUND TO BE OUT OF LIMITS PER SRM 53-00-52-1A-1 REPLACED SEAT TRACK WITH NEW TRACK FROM B.S. 540-72SDR SWAA2021042363554Seat Track · damagedMECHANICAL DAMAGE ON TOP OF SEAT TRACK BS 500B+2 RBL 45 WL208 / REMOVED MECHANICAL DAMAGE ON TOP OF SEAT TRACK BS 500B+2 RBL 45 WL 208 1' X .6 X .004; IS WITHIN LIMITS; APPLIED FINISH TO BARE METAL IAW SRM 53-00-52-1A-1SDR SWAA2021042363567Angle · chafedL/H SKATE ANGLE CHAFED BS 1016-1132 / REMOVED AND REPLACED L/H SKATE ANGLE LOT# 7550174 AT B/S 1016-1132 DUE TO NOT FOUND ALLOWABLE DAMAGE LIMITS ON SRM IAW SRM 51-10-02 PARAGRAPH 9; SRM 51-40-02 AND DWG 148A3590 REV: A. 59900U 10APR21SDR SWAA2021042363568Angle · chafedR/H SKATE ANGLE CHAFED BS 1016-1132 / REMOVED AND REPLACED R/H SKATE ANGLE AT BS 1016 TO BS 1132 IAW SRM 51-40-02 AND DWG 148A3590 REV 'A' 57049U 12APR21SDR SWAA2021042363560Girt Bar · bindingAFT ENTRY DOOR SLIDE GIRT BINDS IN DOOR WHEN CLOSING DOOR / READJUSTED THE GIRT Z-FOLD TO LIFT GIRT TO PREVENT INTERFERENCE PER AMM 25-61-06-SWA-001 STEP 3.K(3) & TASK CARD 725-61-06SDR SWAA2021042362402Beam · crackedDURING COMPLETION OF CCN: 14079 FOUND FORWARD SERVICE DOOR #4 (LOWER) BEAM TO BE CRACKED IN THEA RADIUS ON THE INBOARD SIDE COMMON TO THE FORWARD MOST ATTACH POINT FOR THE DOOR HANDLE BOX ASSEMBLY. / FORWARD SERVICE DOOR #4 LOWER BEAM REPAIRED PER CUSTOMER RO SDR SWAA2021042362297Bulkhead Web · crackedR/H BS 663 GFRP VAPOR BARRIER CRACKED JUST ABOVE HYDRAULIC SERVICE HANDLE / REPAIRED CRACK DAMAGE JUST ABOVE HYDRAULIC SERVICE HANDLE ON R/H BS 663 GFRP VAPOR BARRIER IAW SRM 51-70-04-2R-10 7062U 4-10-21SDR SWAA2021042361806Web · crackedTRANSVERSE WEB ON LEFT WING T/E UPPER SURFACE PANEL JUST AFT OF AFT PYLON TIP IS CRACKED / REMOVED TRANSVERSE WEB ON LEFT WING; T/E UPPER SURFACE PANEL JUST AFT OF PYLON AND REPLACED WITH NEW TRANSVERSE WEB IAW SRM 51-40-02; SRM 51-40-05. AIPC 57-50-00-36A 590SDR SWAA2021042365424Pressure Deck · dentedFLIGHT DECK FLOOR IS DENTED AT B.S. 255; R.B.L. 4 - L.B.L. 14; W.L. 207.54. / FOUND FLIGHT DECK FLOOR DENTS AT B.S. 255 RBL 4 - LBL 14 WL 207.54 TO BE OUT OF LIMITS PER SRM 53-10-51-1A-1 FIG 105 DETAIL D; REPAIRED ON CUSTOMER CARD # 1-A53-33179 REV 1SDR SWAA2021042361532Floor Panel · damagedFWD CARGO BAY FLOOR PNL 120CF DAMAGED / FABRICATED NEW FCB FLOOR PANEL 120CF FROM 090 CONOLITE; LOT# 1454533-1 PER AMM 25-52-01-201-801 AND DWG 453A1610SDR SWAA2021042361540Floor Panel · damagedAFT CARGO BAY FLOOR PNL 140BF DAMAGED / FABRICATD NEW ACB FLOOR PANEL 140BF FROM 090 CONOLITE; LOT # 1454533-1 PER AMM 25-52-01-201-801 AND DWG 453A2610SDR SWAA2021042365022Floor Panel · damagedACCESS AND RESTORE AFT CARGO BAY FOR CARGO BAY PNL REPLACEMENT / REMOVED AND REPLACED FLOOR PANEL 140BF; SIDEWALL PANEL 141BW; 141FW; 141HW; 142BW; 142FW IAW AMM 25-52-10-400-801 AMM 25-52-06-400-801 AND SRM 51-10-02 PARAGRAPH 9. 59900U 15APR21SDR SWAA2021011841525Battery Pack · no testRT AFT EMERGENCY LIGHT BATTERY PACK FAILED CAPACITY CHECK. REMOVED AND REPLACED, PER AMM 33-51-06.
Back to N958WN