N961SW
Service difficulty reports · 174
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N961SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N961SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA200718918Light · shortedFLT 6436 - MAP LIGHTS INOP. FIRST OFFICERS MAP LIGHT POPS THE CIRCUIT BREAKER. SECURED LOOSE HARDWARE ON MAP LIGHT.
SDR SWIA200718891Flap · damagedLEFT OUTBOARD FLAP IS DAMAGED ALONG TRAILING EDGE. REPLACED FLAP PER 27-54-05.
SDR SWIA200617603Support · crackedRT STA 625 BETWEEN STR 12 AND 13 SUPPORT CLIP CRACKED, DISCOVERED DURING C-CHECK INSPECTION. REPLACED CLIP PN 601 35012-52; PONR 70576 AT RT FS 625 BETWEEN STR 12/13 PER CRJ200 REO 601R 53-61-422.SDR SWIA200617602Support · crackedLT STA 625 BETWEEN STR 12 AND 13 SUPPORT CLIP CRACKED, DISCOVERED DURING C-CHECK INSPECTION. REPLACED CLIP PN 601 35012-51 AT LT FS625 BETWEEN STR 12/13 PER CRJ200 REO 601R 53-61-422.SDR SWIA200617601Floorbeam · crackedRT 621.0 FLOORBEAM OTBD SIDE CRACKED, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED ANGLES AT STA 621.0 RT FLOOR SUPPORT PER REO 601R-53-61-117 REV C.SDR SWIA200617600Floorbeam · crackedLT STA 621.0 FLOORBEAM OTBD SIDE CRACKED, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED ANGLE AND REPAIR ANGLE PER BOMBARDIER AEROSPACE REO601R-53-61-117 REV C DATED 2004-AUG-25.SDR SWIA200617598Intercostal · crackedFS 484 INTERCOSTAL CRACKED AT LEFT OUTBOARD SIDE DISCOVERED DURING C-CHECK INSPECTION. INSTALLED REPAIR ANGLE AT OB FS 484 IAW CRJ200 REO 601R-53-41-059 .SDR SWIA200617597Web · crackedPAX DOOR, FWD WEB IS CRACKED UNDER THE HANDRAIL STOW BRACKET, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED EXTERNAL DOUBLER AND REPAIR ANGLES ON PAX DOOR FWD SIDE PANEL IAW REO NR 601R-52-11-702 REV A.SDR SWIA200617596Hand Rail · crackedPAX DOOR - AFT WEB IS CRACKED AT HANDRAIL STOW BRACKET, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED DOUBLER AND REPAIR ANGLES ON PAX DOOR AFT SIDE PANEL IAW REO 601R-52-11-702 REV.SDR SWIA200617595Drag Angle · crackedPAX DOOR, AFT DRAG ANGLE IS CRACKED ADJACENT TO THE PAX DOOR ASSIST MOTOR CABLE PULLEY BRACKET, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED ANGLE SECTION AND SPLICE ANGLE PER REO NR 601R-52-11-513 REV 'A' SHEET 1 OF 3.SDR SWIA200515686Inverter · inoperativeFLOOR EXIT SIGN BY SEAT 8A IS INOP. REPLACED NR 2 INVERTER IAW AMM CH 33-51-00. OPERATIONAL CHECK GOOD.SDR SWIA200515634Switch · intermittent2ND AND 3RD ROWS OF EMERGENCY EXIT LIGHTS INTERMITTENT. REPLACED FA STATION TOGGLE SWITCH. OPERATIONAL CHECK GOOD IAW MM 33-51-01 AND 33-51-00.SDR SWIA200515585Battery · dischargedEMERG LIGHT STRIP (FLOOR) ON RIGHT SIDE IS BURNED OUT. REPLACED NR 2 EMERGENCY BATTERY PACK NR 2 IAW CRJ MM 33-51-04. OPERATIONAL CHECK GOOD, PN ON 2013-1A SN ON 36254 OFF 83055.SDR SWIA200515528Battery Pack · inoperativeFORWARD SECTION OF EMERGENCY LIGHTS ON CABIN FLOOR INOP. REPLACED FWD BATTERY PACK BALLAST. OPERATIONAL CHECK GOOD.SDR SWIA200515469Light · looseEMERGENCY LIGHTS ROWS 2, 3, 4, 5 INOP. RECONNECTED STRIP. OPERATIONAL CHECK GOOD.SDR SWIA200514977Floorbeam · crackedFS 280 AT RBL 9.0 INBOARD AND OUTBOARD FLOORBEAM ATTACH ANGLES CRACKED. ITEM FOUND AT C-CHECK INSPECTION. ANGLE REPLACED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-21, 51-21-11, 51-25-16, 51-23-00.SDR SWIA200514976Floorbeam · crackedFS 280 LBL 9.0 OUTBOARD FLOORBEAM ATTACH ANGLE IS CRACKED. ITEM FOUND AT C-CHECK INSPECTION. ANGLE REPLACED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-21, 51-21-11, 51-25-16, 51-23-00.SDR SWIA200414073Control Lever · malfunctionedAFTER LANDING CHECK FLAPS FAIL CAUTION AFTER RETRACTING TO 30 DEGREES. REPLACED FLAP CONTROL LEVER, OPERATIONAL CHECKED GOOD. P/N OFF 292-65253-1, S/N OFF 592.SDR SWIA200413851Control Unit · malfunctionedSTAB CH1 INOP AND MACH TRIM MESSAGES IN CLIMB (FL240). CLEANED BOTH TRIM SWITCHES AND REPLACED HSTCU IAW CRJ MM 27-41-01. OPERATIONAL CHECK GOOD.SDR SWIA200413806Control Unit · inoperativeSTAB TRIM CHANEL 1 STATUS MESSAGE IN FLIGHT. REMOVED AND REPLACED HORIZONTAL STAB TRIM ACTUATOR, HORIZONTAL STAB MOTOR CONTROL UNIT AND HSTCU IAW AMM 27-42-01AND MM27-42-05. OPERATIONAL CHECK GOOD. P/N: 7060-9 S/N OFF: 1184SDR SWIA200413786Motor · malfunctionedSTAB TRIM CHANNEL 1 DISENGAGED IN FLIGHT. REPLACED MOTOR CONTROL UNIT FOR STAB TRIM. OPERATIONAL CHECK GOOD.SDR SWIA200413413Control Unit · malfunctionedSTAB CHANNEL 1 INOP AFTER T/O. REMOVED AND REPLACED HSTCU, OPERATIONAL CHECK GOOD IAW 27-40-00.SDR SWIA200312732Actuator · malfunctionedSTAB TRIM CH 2 FAILS FFOD CHECK. REMOVED AND REPLACED STAB TRIM ACTUATOR AND MOTOR CONTROL PER TASK CARD RII 27-415. OPS CHECK GOOD. P/N 7062-3, S/N ON 786, S/N OFF 1184.SDR SWIA200312637Control Unit · malfunctionedSTAB CHANNEL 1 INOPERATIVEDL2428M4 STATUS MESSAGE UPON EXTENSION OF FLAPS, WOULD NOT ENGAGE. REMOVED AND REPLACED HSTCU PER CRJ MM 27-40-00.