N965AS

Service difficulty reports not matched to an aircraft · 167

They name N965AS, but no registry record covers the date, the aircraft registered then was built later, or the report describes another aircraft. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N965AS' AND registry_match IS NULL
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR ASAA9980108Wire · brokenSEA - AFTER ARRIVAL OF FLT 483 - CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHTING AT ROW 1 WAS DISLODGED FROM TRACK. REPLACED BROKEN WIRES IN FLOOR TRACK ASSEMBLY, REINSTALLED LIGHTING INTO TRACK AND OPERATED NORMALLY. (M)May 12, 1999 · N965AS · Doug DC983 · Light System WiringSDR ASAA9980100Light · inoperativeSEA - DURING MAINTENANCE CHECK, ONE EMERGENCY FLOOR TRACK LIGHT AT ROW 20 AND TWO AT ROW 23 WERE FOUND INOPERATIVE. REPLACED LAMP MODULES AND OPERATED NORMALLY. (M)May 4, 1999 · N965AS · Doug DC983 · Emergency LightingSDR ASAA9980014Wire · damagedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE FOUND INOPERATIVE. REPAIRED WIRING IN FLOOR TRACK AND OPERATED NORMALLY. (X)Jan 8, 1999 · N965AS · Doug DC983 · Light System WiringSDR ASAA9880266Wire · damagedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS IN FORWARD CABIN WERE FOUND INOPERATIVE. REPAIRED WIRING IN FLOOR TRACK AND OPERATED NORMALLY. (M)Dec 18, 1998 · N965AS · Doug DC983 · Light System WiringSDR ASAA9880248Mechanism · out of adjustSEA - DURING MAINTENANCE CHECK, THE L2 DOOR WOLD NOT LATCH OPEN. ADJUSTED DOOR HOLD OPEN MECHANISM AND OPERATED NORMALLY. (M)Nov 25, 1998 · N965AS · Doug DC983 · Service DoorsSDR ASAA9880170Bottle · dischargedSEA - PRIOR TO DEPARTURE OF FLT 376, CREW REPORTED THE L1 DOOR EMERGENCY EVACUATION SLIDE INFLATION BOTTLE PRESSURE WAS LOW. REPLACED THE L1 DOOR EMERGENCY EVACUATION SLIDE ASSY. (M)Sep 4, 1998 · N965AS · Doug DC983 · Escape SlideSDR ASAA9880162Batteries · dischargedSEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS FROM ROWS 1 TO 6 WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND OPERATED NORMALLY. (M)Aug 26, 1998 · N965AS · Doug DC983 · Emergency LightingSDR ASAA9880040Batteries · dischargedSEA - FLT 446 - PRIOR TO DEPARTURE, THE EMERGENCY FLOOR TRACK LIGHTS IN THE FIRST CLASS CABIN WERE INOPERATIVE. REPLACED THE BATTERY PACK AND REPAIRING WIRING IN PART OF SECTION, LIGHTS OPERATED NORMALLY. (M)Mar 3, 1998 · N965AS · Doug DC983 · Emergency LightingSDR ASAA9780294Release · lack of lubeSEA - DURING TAILCONE EMERGENCY RELEASE CHECK FROM THE AFT CABIN ENTRY DOOR POSITION, THE TAILCONE FAILED TO RELEASE. LUBRICATED TAILCONE RELEASE MECHANISM AND TAILCONE RELEASED NORMALLY. (M)Dec 23, 1997 · N965AS · Doug DC983 · Aerodynamic FairingsSDR ASAA9780247Emerg Evac Slide · low pressurePDX - DURING MAINTENANCE CHECK, THE R1 DOOR EMERGENCY EVACUATION SLIDE INFLATION BOTTLE PRESSURE WAS FOUND LOW. REPLACED THE R1 DOOR EMERGENCY EVACUATION SLIDE ASSEMBLY. (M)Oct 14, 1997 · N965AS · Doug DC983 · Escape SlideSDR ASAA9780108Light · defectiveLAX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)Jun 6, 1997 · N965AS · Doug DC983 · Emergency LightingSDR ORJA9780006Power Supply · defectivePDX - DURING MAINTENANCE CHECK, THE EXTERIOR OVERWING EMERGENCY LIGHTS WERE FOUND INOPERATIVE. REPLACED THE POWER SUPPLY AND OPERATED NORMALLY. (M)Jan 10, 1997 · N965AS · Doug DC983 · Emergency LightingSDR ASAA9680262Light · defectivePDX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND DIM. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)Nov 25, 1996 · N965AS · Doug DC983 · Emergency LightingSDR ASAA9680236Light · defectivePDX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND DIM. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)Oct 19, 1996 · N965AS · Doug DC983 · Emergency LightingSDR ASAA9680079Wire · disconnectedSEA - DURING MAINTENANCE CHECK, FORWARD 4 EMERGENCY EXIT TRACK LIGHTS WERE FOUND TO BE INOPERATIVE. RECONNECTED LIGHTS/WIRING AND LIGHTS OPERATED NORMALLY. (M)Mar 24, 1996 · N965AS · Doug DC983 · Light System WiringSDR ASAA9580197Hold Open Latch · out of adjustSEA - DURING MAINTENANCE CHECK, THE L1 DOOR HOLD OPEN HOOK WOULD NOT ENGAGE. ADJUSTED HOLD OPEN LATCH AND OPERATED NORMALLY. (M)Sep 15, 1995 · N965AS · Doug DC983 · Passenger/Crew DoorsSDR ASAA9580171Portable Eel · defectiveSFO - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSY AND OPERATED NORMALLY. (M)Jul 30, 1995 · N965AS · Doug DC983 · Emergency Lighting
Back to N965AS