N987AM
Service difficulty reports · 106
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N987AM' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N987AM' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201707199001Smoke Detector · false activationAIRCRAFT WAS NOT GROUNDED. AT CRUISE ALTITUDE FL260, RECEIVED ECAM MESSAGE SMOKE LAVATORY, SMOKE RED WARNING, AND MESSAGE CLEARED WITHIN 30 SECONDS. FLIGHT ATTENDANT SAID IT WAS LAVATORY D. THEY CHECKED THE LAVATORY AND WASTE RECEPTICAL WITH NO EVIDENCE OF SMOSDR AALA201707109047Battery · no testCIDS 1 TEST MESSAGE 335100 BATTERY, EMERGENCY POWER SUPPLY UNIT 13WL. REPLACED EMERGENCY POWER SUPPLY UNIT BATTERY 13WL IAW AMM 33-51-38.SDR AALA201705269024Relay · faultedDURING APPROACH, WHEN GEAR SELECTED DOWN, AN ECAM MESSAGE FOR LANDING GEAR NOT DOWNLOCKED. APPLIED LANDING GEAR GRAVITY EXTENSION PROCEDURES IAW QRH. MAINTENANCE REPLACED RIGHT GEAR SAFETY VALVE RELAY (62GA) IAW MM 32-31-07 AND ACCOMPLISHED OPERATIONAL CHECSDR AALA201705259016Proximity Sensor · malfunctionedDURING APPROACH, WHEN THE MLG WAS SELECTED DOWN, AN ECAM FOR LANDING GEAR NOT DOWNLOCKED. APPLIED LANDING GEAR GRAVITY EXTENSION PROCEDURES IAW QRH. MAINTENANCE REPLACED RIGHT MLG PROXIMITY SENSOR 22GA IAW MM 32-31-73, AND ACCOMPLISHED AN OPERATIONAL CHECK ISDR AALA201705219004Actuator · malfunctionedAIRCRAFT WAS GROUNDED. ON FINAL APPROACH, INTO MCO, CREW REPORTED LANDING GEAR NOT DOWNLOCKED. DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. RAN QRH PROCEDURE, MANUAL EXTENSION. MAINTENANCE REPLACED LEFT HAND MAIN LANDING GEAR DOOR ACTUATOR PER AMM 32-31-SDR AALA201703249007Damper · low pressureR1 DOOR DAMPER PRESSURE BELOW LIMITS. SERVICED THE DAMPER IAW AMM 52-11-00.
Back to N987AM