N993AT
Service difficulty reports · 210
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N993AT' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N993AT' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ZZDA2011854Web · corrodedMAIN CABIN FLOOR WEB, STA 190 TO 200, BL 0, CORROSION. ACCOMPLISHED FLOOR WEB DOUBLER REPAIR PER B717 SRM 51-70-10 AND 51-41-02.SDR ZZDA2011302Cover · out of positionCREW REPORTED R1 DOOR SLIDE COVER FELL OFF. (REINSTALLED/ NOTED IN RESOLUTION/RE-INSEPCTION REQUIRED). REMOVED AND REPLACED R-1 DOOR SLIDE PER AMM 25-61.SDR ZZDA2010574Unknown · malfunctionedDURING EMERGENCY POWER TEST, RELAY CLOSED AND THEN FAILED TO OPEN. RESTARTED TEST (2X). EMERGENCY TEST FAIL (2X). REMOVED POWER FROM EMERGENCY AC BUS, APPLIED POWER AND PERFORMED EMERGENCY POWER TEST TWICE WITH NO DISCREPANCIES REF FIM 24-24 TASK 803.SDR ZZDA2009312Frame · corrodedAFT CARGO COMPARTMENT FUSELAGE FRAME AT FS 870, AFT SIDE HAS CORROSION AT LONGERON 30. INSTALLED REPAIR SPLICE AT AFT CARGO COMPARTMENT FUSELAGE FRAME FS 870 AT LONGERON 30 IAW B717 SRM 53-20-07 REPAIR 3 FIG 201.SDR ZZDA2009314Frame · damagedEO 17-5310-2895 AFT RIGHT STA 1178 CANTED FRAME INSPECTION IDENTIFIED CONFIGURATION 2 CONDITION 5. ACCOMPLISHED REPAIR TO AFT FUSELAGE FRAME CAP, CANTED STA 1178.225, RIGHT SIDE IAW TASK CARD 17-5310-2990.SDR ZZDA2009313Frame · damagedEO 17-5310-2937 AFT LEFT STA 1178 CANTED FRAME INSPECTION IDENTIFIED CONFIGURATION 1 CONDITION 1. ACCOMPLISHED REPAIR TO AFT FUSELAGE FRAME CAP, CANTED STA 1178.225, LEFT SIDE IAW TASK CARD 17-5310-2973.SDR ZZDA2009311Door Frame · corrodedAFT CARGO DOOR JAMB CUTOUT AREA HAS CORROSION STA FROM 954 TO 994. INSTALLED AFT CARGO COMPARTMENT DOOR JAMB LOWER SPLICE REPAIR PER B717 SRM 53-20-15 REPAIR 7 FIGURE 201. SEE NR 3797, 3829 AND 2382.SDR ZZDA2008018Battery Pack · dischargedEPL INOP AT ROWS 1-10. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY SUPPLY ASSY AT POS NR 4 EPL, OPS OK M/M 33-51.SDR AT0700013Skin · dentedDENT AT P$237L LONG 18L AND RUNS FROM L18 UP 5 INCHES ABOVE L18 MEASURES 5 X 5 X .035. REPAIR DENT AT P$237L LONG 18C IAW B717 SRM 53-00-01 FIG 201.SDR AT0600027Slide · deployedR1 DOOR SLIDE DEPLOYED AND GIRT BAR WAS IN PLACE. R/R R-1 SLIDE PER AMM 25-61-03.