N117MV, cancelled May 10, 2012
Service difficulty reports · 19
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N117MV' AND deregistration_id = 'N117MV-2012-05-10' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N117MV' AND deregistration_id = 'N117MV-2012-05-10' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R7MR35541Seal Ring · wornSEAL RING WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR35543Nozzle · burnedNOZZLE HAS EXCESSIVE BURNS IN SOME AREAS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR 20000608SH028Bushing · wornBUSHING TEFLON LINERS WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000608SH027Bushing · wornBUSHING TEFLON LINERS WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000816SH020Ring · wornSEAL RING WORN BEYOND SEVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000816SH019Spring · wornSPRING WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000816SH018Shroud · bindingEXCESSIVE GP BLADE TIP RUB. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000816SH017Curl · crackedCURL ASSY CRACKED BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000816SH016Tube · leakingTUBE ASSY LEAKING BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000816SH015Tube · leakingTORQUEMETER FEED LEAKING BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000816SH014Seal · leakingSEAL LEAKING BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000816SH013Seal · leakingSEAL LEAKING BEYOND SERVCIEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000816SH012Thermocouple · shortedINTERNAL SHORT. REPLACED THERMOCOUPLE WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 2000ZZZX799Bolt · wornBOLT WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR 99ZZZX3869Bolt · wornBOLT WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR 98ZZZX3385Seal · wornSEAL WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR 97ZZZX4098Bearing · wornBEARING WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH 2 EACH NEW UNITS, CORRECTED PROBLEM.SDR 97ZZZX2424Bearing · defectiveNR 2 BEARING HAS FLAT SPOTS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR 95ZZZY0965Fitted Bolt · wornFITTED BOLT WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT(S), CORRECTED PROBLEM.
Back to N117MV, cancelled May 10, 2012