N12505, cancelled Nov 8, 2012
Service difficulty reports · 35
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N12505' AND deregistration_id = 'N12505-2012-11-08' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N12505' AND deregistration_id = 'N12505-2012-11-08' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA0000002Lens · brokenDTW - RIGHT FORWARD OVERWING EXIT EMERGENCY LIGHT LENS COVER BROKEN. REPLACED RIGHT FORWARD OVERWING EXIT EMERGENCY LIGHT COVER. CHECKS NORMAL IAW DC-9 MM 33-00-00. (M)SDR GTIA9901002Wire · brokenMYR - FORWARD EMERGENCY FLOOR LIGHTING 4 RED LENS INOPERATIVE. FOUND 1 POWER WIRE BROKEN UNDER CARPET. REPAIRED SAME. OPERATIONAL CHECK GOOD. (M)SDR GTIA9900939Slat · damagedEWR - LEFT WING HAS DAMAGED AREAS. NR 4 L/E SLAT. REMOVED AND REPLACED NR 4 L/E SLAT IAW DC-9 MM 27-80-1. (M)SDR GTIA9900033Light · miswiredDTW - EMERGENCY LIGHTS AT ROW 17 AND 18 WON'T LIGHT, OVERHEAD. UNCROSSED EMERGENCY AND STANDBY LIGHT WIRES. OPERATION CHECK GOOD IAW DC-9 MM 33-50-0. (M)SDR GTIA9800069Fuse · blownDTW - TAIL CONE CATWALK EMERGENCY TRACK LIGHTING INOPERATIVE. INSTALLED FUSE IN BATTERY PACK, OPERATIONAL CHECK GOOD. (X)SDR GTIA9800055Power Supply · failedAFT STAIRWAY EMERGENCY TRACK LIGHTING INOP. FOUND BURNED OUT POWER SUPPLY. REMOVED AND REPLACED POWER SUPPLY IAW MM 33-50-00, OPERATIONAL CHECK GOOD. (M)SDR GTIA9800008Wire · brokenACY - FLT 119 - CABIN FLOOR LIGHTING REAR EMERGENCY EXIT ROW NEEDS FIXING. REPAIRED WIRING AT SEAT TRACK SEAT 11 IAW W/D 33-51-03. GROUND OPS CHECK OK. (M)SDR GTIA9800004Bulb · failedDTW - ONE RED FLOOR PATH LIGHT INOPERATIVE AT FORWARD EMERGENCY EXIT ROW 14. REPLACED ONE FLOOR PATH BULB ASSEMBLY. OPS CHECK GOOD IAW MM 33-50. (M)SDR GTIA9700400Brake Bleeder · looseMSP - FLT 900 - ON LANDING AT MSP, TOWR REPORTED SMOKE FROM RIGHT GEAR AREA. INSPECTED RIGHT MLG FOUND NR 4 BRAKE LEAKING FROM BLEEDER. PARTS TIGHTENED SECURELY AND SAFETIED. OPS CHECK GOOD, NO LEAKS NOTED. (M)SDR GTIA9700379Control Cable · brokenDTW - FLT 420 - LEFT INBD FLAP MOVEABLE VAN CABLE 168A, FOUND BROKEN. REMOVED AND REPLACED LEFT INBOARD FLAP MOVEABLE VANE CABLE IAW MM 37-51-2. RIGGED/ADJUST TEST ALSO IAW MM 27-51-2. (M)SDR GTIA9700358Battery Pack · dischargedMYR - FLT 1601 - EMERGENCY EXIT LIGHTS OVER WING 1/2 EACH INOPERABLE. (EXIT ROW 15). REMOVED AND REPLACED EMERGENCY POWER SUPPLY BATTERY PACK WITH SERVICEABLE BATTERIES IAW DC-9 MM 33-50. OPERATIONAL CHECK GOOD AT OVER THE WING EMERGENCY EXIT ROW 15. (X)SDR GTIA9700353Power Supply · inoperableMYR - FLT 1601 - EMERGENCY EXIT LIGHTS OVER WING 1/2 EACH INOPERABLE. (EXIT ROW 15.) REMOVED AND REPLACED EMERGENCY POWER SUPPLY BATTERY PACK WITH SERVICEABLE BATTERIES IAW DC-9 MM 33-50. OPERATIONAL CHECK GOOD. (X)SDR GTIA9700344Adi · failedDTW - FLT 177 - AFTER PUSHBACK AND ENGINE START, FO ADI PROCESSED 30 DEGREES TO THE RIGHT, AND ROLL ANNUNCIATOR ON COMPARATOR PANEL ILLUMINATED. REMOVED AND REPLACED F/O'S ADI. OPS CHECK GOOD IAW DC-9 MM 34-22-0. (M)SDR GTIA9700339Socket · brokenMYR - FLT 111A - EMERGENCY FLOOR TRACK LIGHT SOCKET AND LENS BROKEN AT ROW 14 D, E, F AND RE-LAMPED SOCKET IAW DC-9 MM 33-50. OPS CHECK GOOD. (M)SDR 97ZZZM749Lens · brokenMYR - FLT 111A - EMERGENCY FLOOR TRACK LIGHT SOCKET AND LENS BROKEN AT ROW 14 D, E, F. REMOVED AND REPLACED EMERGENCY FLOOR TRACK LIGHT SOCKET AND LENS (RED) AND ROW 14 D, E, F AND RE-LAMPED SOCKET IAW DC-9 MM 33-50. OPS CHECK GOOD. REFERENCE GTIA9700339.SDR GTIA9700324Wire · failedACY - FLT 186 - DURING TAXI OUT, NO ELEVATOR POWER ON TEST. RETURNED TO GATE. TRANSFERRED TO DMI NR 000659 PER MEL 27-14, CAT 'C'. PLACARDS INSTALLED. REPAIRED WIRES AT PRESSURE SWITCH. OPS CHECK NORMAL IAW MM 27-30-12. THIS CLEARS DMI NR 00659. PLACARDSDR GTIA9700275Light · missingMYR - FLT 243 - EMERGENCY FLOOD TRACK LIGHT SYSTEM MISSING RED EXIT LENS COVER AND LIGHT BULB AT ROW 15 D, E, F. RELAMPED EMERGENCY FLOOR TRACK LIGHT BULB AT ROW 15, D, E, F AND INSTALLED RED LENS COVER ON FLOOD TRACK. OPS CHECK GOOD. (M)SDR GTIA9700269Slide Pack · fell offDTW - FLT 174 - MAIN DOOR SLIDE PACK FELL OFF. INSTALLED L1 EMERGENCY ESCAPE SLIDE IAW DC9 MM 25-61-0. (M)SDR GTIA9700260Door · not latchedMYR - FLT 243 - 'AFT CABIN DOOR' CAUTION LIGHT ILLUMINATED DURING DESCENT AND REMAINED ON. NO OTHER INDICATIONS. INSPECTED AND FOUND DOOR HANDLE TO BE PARTIALLY OPEN, CYCLED DOOR HANDLE CLOSED, LIGHT OUT. LIGHT AND DOOR CHECKS NORMAL. OK TO CONTINUE. (M)SDR GTIA9700259Logo Light · missingMYR - FLT 1701 - RIGHT LOGO LIGHT DISCOVERED MISSING ON POST FLT INSPECTION. TRANSFERRED TO DMI NR 00292 PER MEL 33-23. CAT 'C'. BOS, INSTALLED LAMP, LOUVER AND CLIPS ON RT LOGO IAW DC-9 MM CHAPTER 33. OPS CHECK GOOD. CLEARS DMI NR 00292. (M)SDR 97ZZZM249Breaker · trippedFLT 195 - BOS - AT BOSTON AFTER ENGINE STARTS, LEFT ENGINE GENERATOR DROPPED OFF LINE. CAPTAIN RESET IT ON AND CROSS TIE LOCK OUT CAME ON. WENT BACK TO GATE AND RESET CROSS TIE. RESET LOCK OUT TIE BREAKER. OPS CHECK OK IAW 24-50. (M)SDR 97ZZZM248Wheels · looseFLT 301 - ACY - NOSE GEAR VIBRATES BADLY ON TAKEOFF, FEELS OUT OF BALANCE. SNUBBER DOES NOT SEEM TO STOP IT ON GEAR UP. RE-TORQUED BOTH NOSE TIRES IAW MM CHAPTER 32-40-2. NO TIRE DEFECTS NOTED. (M)SDR 97ZZZM250Slide · malfunctionedCIT - FLT 851 - FORWARD CABIN DOOR SLIDE FELL OFF AND INFLATED WHEN DOOR WAS OPENED. REMOVED AND REPLACED FORWARD ENTRY DOOR SLIDE IAW MM 25-62. OK FOR SERVICE. INSPECTED INSTALLATION OF FORWARD ENTRY DOOR SLIDE PER MM 25-62-0. (M)SDR 961209001Engine · failedDTW - FLT 626 - IN CRUISE CONFIGURATION, NR 2 THROTTLE SPLIT 3.50 INCHES WITH NR 1 THROTTLE. NR 2 EGT AND FUEL FLOW HIGH, DURING ENGINE ACCELERATION COMPRESSOR STALLS WERE EXPERIENCED ON NR 2 ENGINE. CORRECTIVE ACTION: MAINTENANCE INSPECTED NR 2 ENGINE AND SDR 961128001Oil Cap · looseDTW - FLT 423 - IN CLIMB CONFIGURATION, FLIGHT CREW OBSERVED NR 1 ENGINE OIL QUANTITY DECREASE FROM 16 QUARTS TO 6 QUARTS. RETURNED TO DTW WITHOUT INCIDENT. MAINTENANCE FOUND NR 1 ENGINE OIL TANK SERVICE CAP NOT SECURED. SERVICED ENGINE WITH OIL, SECURED OISDR GTIA96NK211Fuse · blownAFT SECTION OF EMERGENCY FLOOR TRACK LIGHTING INOPERATIVE. REMOVED AND REPLACED BLOWN FUSE IN BATTERY PACK, OPERATIONAL CHECK GOOD IAW DC-9 MM CH 33-53-01. (M)SDR GTIA96NK199Pressure System · failedAIRCRAFT LOG PAGE NR 028813, ITEM NR P744 - PRESSURIZATION FAILED ON TAKEOFF OUT OF ACY. RETURNED ON TAKEOFF, OUT OF ACY. RETURNED FOR MAINTENANCE INSPECTION. DEFERRED PRESSURIZATION IAW MEL 21-24, DMI NR 2595. (M)SDR GTIA96NK167Seat Belt · cutFORWARD LIGHT ATTENDANT JUMPSEAT OUTBOARD SEAT BELT INBOARD HARNESS STRAP CUT AND FRAYED. REPLACED SEAT BELT HARNESS STRAP. (M)SDR GTIA96NK166Floor Board · corrodedDURING C-CHECK, FOUND CENTER COCKPIT FLOOR BOARD CORRODED. FABRICATED, TREATED AND INSTALLED REPLACEMENT FLOOR BOARD IAW 51-10-2, 51-10-3, 51-30-0 AND 51-20-0. (M)SDR GTIA96NK165Strap · corrodedDURING C-CHECK, FOUND FORWARD CARGO BAY STATION 327 TO 370, RIGHT SIDE RBL 17 FLOOR BOARD SUPPORT STRAP CORRODED. FABRICATED SUPPORT STRAP AND TREATED CORROSION IAW SRM 53-03, 51-10-3. (M)SDR GTIA96NK164Rib Cap · corrodedDURING C-CHECK, FOUND CORRODED RIB CAP IN AFT CARGO COMPARTMENT STATION 930 LEFT. FABRICATED, TREATED AND INSTALLED NEW RIB CAP IAW SRM 51-10-3, 51-10-1 AND 51-10-4. (M)SDR GTIA96NK163Membrane · corrodedDURING C-CHECK, FOUND LEVEL 2 CORROSION IN GALLEY DOOR ENTRY WAY AT FS 180 AND APPROX 40 INCHES RIGHT OF CENTERLINE. ALSO, MEMBRANE HAS CORROSION UNDER THE SEAM AREA. REMOVED CORROSION AND REPLACED MEMBRANE, TREATED AREA IAW 53-10, 51-10-3 AND 51-30-0. (M)SDR GTIA96NK162Floor Support · corrosionDURING C-CHECK, FOUND FLOOR SUPPORT MEMBER IS GALLEY SERVICE DOOR ENTRYWAY, 36 INCHES RIGHT OF CENTER CORRODED ALONG TOP OF FLANGE. FABRICATED, TREATED AND INSTALLED NEW FLOOR SUPPORT IAW SRM 51-10-1, 51-30-0 AND 51-10-3. (M)SDR GTIA96NK161Floor Support · corrosionDURING C-CHECK, FOUND UNDER FLOOR MEMBRANE CORRODED ALONG FLOOR SUPPORT MEMBER BETWEEN FS 160-200, 36 INCHES LEFT OF CENTER. FABRICATED, TREATED AND INSTALLED NEW MEMBRANE IAW SRM 53-01, 51-10-03, AND 51-30-0. (M)SDR GTIA96NK160Floor Support · exfoliatedDURING C-CHECK, FOUND FORWARD ENTRY DOOR WAY FLOOR SUPPORT MEMBER AT FS 160-200 EXFOLIATED. FABRICATED, TREATED AND INSTALLED NEW FLOOR SUPPORT IAW SRM 51-10-1, 51-30-0, 51-10-3. (M)
Back to N12505, cancelled Nov 8, 2012