N132NK, cancelled May 17, 2006

Service difficulty reports · 25

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N132NK' AND deregistration_id = 'N132NK-2006-05-17'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR GTIA9901228Light · looseACY - FLT 262 - PATH LIGHTING STRIP IS COMING UP. REATTACH PATHWAY LIGHTING STRIP. OPS GOOD AS PER 33-50-00. (M)Dec 12, 1999 · N132NK · Doug DC931 · Emergency LightingSDR GTIA9901204Light · looseMCO - FLT 729 - TRANSFERRED FROM CABIN LOG CONTROL NR 12034 AISLE PATH LIGHTING STRIPS TORN LOOSE AT ROW 9 AND 21. RE-INSTALLED AND SECURED FLOOR PATH LIGHTING AT ROW 9 AND 21. OPS CHECK GOOD IAW MM 33-51-00. (M)Nov 11, 1999 · N132NK · Doug DC931 · Emergency LightingSDR GTIA9901194Light · inoperativeDTW - FLT 605 - EMERGENCY FLOOR LIGHTING INOPERATIVE. REPAIR TRACK LIGHT WIRING AT ROW NR 9, OPS CHECKED GOOD IAW DC-9 MM 33-50. (M)Nov 9, 1999 · N132NK · Doug DC931 · Emergency LightingSDR GTIA9901106Wire · failedACY - ONE RED STRIP AT EMERGENCY EXIT LIGHTING INOPERATIVE. REPAIRED WIRING AT EMERGENCY LIGHT STRIP IAW MM DC9 33-00-00. OPS CHECK GOOD. (M)Sep 1, 1999 · N132NK · Doug DC931 · Light System WiringSDR GTIA991104Wire · brokenACY - FLT 430 - ONE RED STRIPPED EMERGENCY EXIT LIGHTING INOPERATIVE. REPAIRED WIRING AT EMERGENCY LIGHT STRIP IAW DC-9 MM 20-00. OPERATION CHECK OK. (M)Aug 31, 1999 · N132NK · Doug DC931 · Light System WiringSDR GTIA9901097Power Supply · inoperativeDTW - COCKPIT EMERGENCY OVERHEAD LIGHT INOPERATIVE. REMOVED AND REPLACED BATTERY POWER SUPPLY AND OPERATION CHECKS IAW DC-9 MM 33-50-00. OPERATION CHECK GOOD, NO DEFECTS NOTED AT THIS TIME. (M)Aug 27, 1999 · N132NK · Doug DC931 · Emergency LightingSDR GTIA9901087Slide · detachedGALLEY SERVICE DOOR SLIDE PACK WAS FOUND LAYING ON GALLEY FLOOR. NEEDS TO BE REPLACED. REINSTALLED GALLEY SERVICE DOOR SLIDE PACK IAW DC9 MM 25-61-00. (M)Aug 21, 1999 · N132NK · Doug DC931 · Emergency EquipmentSDR GTIA9901061Battery Pack · dischargedROWS 1 AND 2 OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK B5-40 IAW 33-53-0. OPERATIONAL CHECKS GOOD. (M)Aug 9, 1999 · N132NK · Doug DC931 · Emergency LightingSDR GTIA9901059Battery Pack · dischargedFORWARD OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK B5-40 IAW MM CHAPTER 33-53-0. OPERATION CHECKS GOOD. (M)Aug 3, 1999 · N132NK · Doug DC931 · Emergency LightingSDR GTIA9901033Battery Pack · dischargedMYR - FORWARD OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK AT B5-40 IAW MM CHAPTER 33-53-0, OPERATIONAL CHECK GOOD. (X)Aug 3, 1999 · N132NK · Doug DC931 · Emergency LightingSDR GTIA9900946Slide · detachedDTW - FLT 546 - SLIDE PACK FELL OFF GALLEY SERVICE DOOR (TWICE) R1. RE-INSTALLED ESCAPE SLIDE ON R1 DOOR IAW DC-9 MM 25-61. (X)Jul 1, 1999 · N132NK · Doug DC931 · Emergency EquipmentSDR GTIA9900012Light · inoperativeDTW - ONE FLOOR TRACK LIGHT DOESN'T WORK. RELAMPED FLOOR TRACK, OPERATION CHECK GOOD IAW MM 33-50-00. (M)Jan 29, 1999 · N132NK · Doug DC931 · Emergency LightingSDR GTIA9800096Light · inoperativeDTW - EMERGENCY FLOOR TRACK LIGHT IN AFT SECTION, LIGHTS NOT WORKING. REPLACED BAD SPLICE. OPERATIONAL CHECK GOOD IAW DC-9 MM 33-50-0. (X)Aug 14, 1998 · N132NK · Doug DC931 · Emergency LightingSDR GTIA9800094Light · inoperativeDTW - SEVERAL CABIN EMERGENCY LIGHTS BURNED OUT. REMOVED AND REPLACED BURNED OUT CABIN EMERGENCY LIGHTS WITH NEW EMERGENCY LIGHTS AS REQUIRED IAW DC9 MM 33-53-00, OPERATIONAL CHECK GOOD. (X)Aug 12, 1998 · N132NK · Doug DC931 · Emergency LightingSDR GTIA9800078Slide · looseATL - FLT 810 - GALLEY DOOR SLIDE PACK DISLODGED ARRIVAL ATL FLT 810 ACY-ATL. RESECURED SLIDE IAW 25-60. RII ACCOMPLISHED. (M)Jul 5, 1998 · N132NK · Doug DC931 · Emergency EquipmentSDR GTIA9800073Slide · separatedDTW - FLT 172 - RIGHT GALLEY PACK SLIDE OFF. INSTALLED L2 DOOR SLIDE PACK IAW DC9 MM 25-61-0. RII ACCOMPLISHED. (X)Jun 23, 1998 · N132NK · Doug DC931 · Escape SlideSDR GTIA9800014Light · inoperativeACY - FLT 119 - FORWARD EMERGENCY FLASHLIGHT INOP NOT FLASHING. REMOVED AND REPLACED FORWARD EMERGENCY FLASHLIGHT, OPS CHECK GOOD ON GROUND. (M)Jan 18, 1998 · N132NK · Doug DC931 · Emergency LightingSDR GTIA9700392Lights · inoperativeDTW - FLT 420 - COCKPIT EMERGENCY EVACUATION LIGHTS INOPERATIVE. REMOVED AND REPLACED COCKPIT EMERGENCY EVACUATION LIGHT BATTERIES IAW DC9 MM 33-53-0, OPS CHECK GOOD. (M)Oct 28, 1997 · N132NK · Doug DC931 · Emergency LightingSDR GTIA9700388Cover · fell offTPA - FLT 637 - GALLEY DOOR SLIDE PACK COVER FELL OF DOOR DURING TAXI FOR TAKEOFF. RETURNED TO GATE FOR MAINTENANCE TO REATTACH. REINSTALLED SLIDE PACK COVER IAW DC9MM 25-62-0. RII INSPECTION PERFORMED. (M)Oct 25, 1997 · N132NK · Doug DC931 · Emergency EquipmentSDR GTIA9700387Light · crackedDTW - EMERGENCY FLOOR LIGHTING TRACK IN ROW 2D IS CRACKED. REMOVED AND REPLACED FLOOR LIGHT TRACK IN ROW 2D AND RESECURED ALL LIGHT LENSES PROPERLY. OPS CHECK IS GOOD. (M)Oct 23, 1997 · N132NK · Doug DC931 · Emergency LightingSDR GTIA9700386Light · brokenDTW - EMERGENCY FLOOR LIGHTING TRACK IN ROW 1 EF IS CRACKED AND LIGHT LENS POPPED OUT OF PLACE. REMOVED AND REPLACED FLOOR LIGHT TRACK IN ROW 1EF AND RESECURED ALL LIGHTS LENSES PROPERLY. OPS CHECK IS GOOD. (M)Oct 22, 1997 · N132NK · Doug DC931 · Emergency LightingSDR GTIA9700376Mechanism · lack of lubePIE - FLT 220 - COCKPIT DOOR WILL NOT STAY CLOSED. FOUND UPPER LATCH STICKING. LUBED UPPER LOCKING LATCH. DOOR STAYS CLOSED AS REQUIRED PER MM 52-00. (X)Sep 29, 1997 · N132NK · Doug DC931 · Passenger/Crew DoorsSDR GTIA9700366Battery · missingDW - FLT 420 - AFT LAVATORY SMOKE DETECTOR MISSING BATTERY. RE-INSTALLED BATTERY IN AFT LAVATORY SMOKE DETECTOR AS REQUIRED. PUSH-TO-TEST GOOD. (X)Aug 20, 1997 · N132NK · Doug DC931 · Smoke DetectionSDR GTIA9700341Lens · missingDTW - MISSING CEILING EMERGENCY LIGHT LENS COVER IN ROW 8 ON THE LEFT HAND SIDE. INSTALLED MISSING CEILING EMERGENCY LIGHT LENS COVER IN ROW 8 ON LEFT HAND SIDE. (X)Jul 9, 1997 · N132NK · Doug DC931 · Emergency LightingSDR GTIA9700315Battery Pack · dischargedDTW - ENTRY DOOR EMERGENCY LIGHT DOES NOT WORK. REPLACED EMERGENCY LIGHT BATTERIES IAW DC-9 MM 33-509-00. OPS CHECK GOOD. (X)Jun 15, 1997 · N132NK · Doug DC931 · Emergency Lighting
Back to N132NK, cancelled May 17, 2006