N171LF, cancelled Aug 10, 2011
Service difficulty reports · 21
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N171LF' AND deregistration_id = 'N171LF-2011-08-10' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N171LF' AND deregistration_id = 'N171LF-2011-08-10' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DU4R2008265Strap · corrodedDURING SCHEDULED INSPECTION AT TIMCO-LCQ FOUND CORROSION ON CABIN FLOOR STRAP AT BS 299, LBL 53.SDR DU4R2008263Floorbeam · corrodedFOUND CORROSION IN AFT PIT ON TOP SURFACE OF FLOORBEAM AT BS 787 TO BS 847 RBL 16.SDR DU4R2008264Repair · crackedDURING SCHEDULED INSPECTION, FOUND A TEMPORARY REPAIR AT LBL 33 AND LBL 41 CRACKED AND REQUIRING REPAIR.SDR DU4R2008259Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORRODED FLOOR BEAM AT BS 967 LBL 16 IN AFT CABIN.SDR DU4R2008258Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORRODED FLOORBEAM AT BS 947 LBL 53 IN AFT CABIN.SDR DU4R2008257Shear Tie · corrodedDURING SCHEDULED INSPECTION FOUND CORRODED SHEAR TIE AT BS 986 RBL 39 TO LBL 44 IN AFT CABIN.SDR DU4R2008256Shear Web · corrodedDURING SCHEDULED INSPECTION, FOUND CORRODED SHEAR DECK AT BS 1010 LBL 31 IN AFT CABIN.SDR DU4R2008255Floor Support · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON FLOOR SUPPORT AT BS 344 BL 0 TO BL 10R.SDR DU4R2008254Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON FLOOR SUPPORT AT BS 328 RBL 9 - RBL 31.SDR DU4R2008253Web · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON UPPER SURFACE OF UPPER WEB BS 787 TO BS 847 S-25R IN AFT CARGO PIT.SDR DU4R2008252Structure · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON INNER CHORD AT LT OB FLOOR STRUCTURE AT BS 685-727.SDR DU4R2008251Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON FLOOR BEAM BS 312 LBL 13-30.SDR DU4R2008250Floor Support · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON FLOOR SUPPORT BS 340 LBL 22.SDR DU4R2008249Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON FLOOR BEAM BS 344 LBL 22.SDR DU4R2008248Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON BS 340 FLOOR SUPPORT LBL 11.SDR DU4R2008247Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON BS 325 FLOOR SUPPORT RBL 10.SDR DU4R2008246Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON BS 294 FLOORBEAM BL 0 TO BL 10R.SDR DU4R2008245Floor Support · crackedDURING SCHEDULED INSPECTION, FOUND FLOOR SUPPORT CRACKED AT BS 316 TO BS 324 RBL 30.SDR DU4R2008244Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON FLOORBEAM AFT CABIN BS 947 LBL 53.SDR DU4R2008243Floorbeam · corrodedDURING SCHEDULED INSPECTION, FL FOUND CORROSION ON FLOORBEAM AFT CABIN STA 986 RBL 39 TO LBL 44.SDR DU4R2008242Angle · chafedDURING SCHEDULED INSPECTION, FOUND LT IB FLAP RIB CHAFED AT IB TRACK FOR FORE FLAP ROLLER.
Back to N171LF, cancelled Aug 10, 2011