N1968R, cancelled Feb 21, 2001
Service difficulty reports · 176
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1968R' AND deregistration_id = 'N1968R-2001-02-21' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1968R' AND deregistration_id = 'N1968R-2001-02-21' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RAAA00E9033Battery · dischargedDURING SERVICE CHECK FOUND SERVICE DOOR EXIT IDENTIFIER WOULD NOT STOP FLASHING. REPLACED BATTERY, OPS CHECK GOOD PER RAA ECO 86-25.SDR RAAAOOE9032Governor · intermittentNR 4 PROP 14,200 GOING HIGHER (K3, K2) IN K1 RPM SLOWER BUT OSCILLATES BETWEEN 13,400 TO 14,150. REPLACED PROP GOVERNOR VALVE IAW AEROPRODUCTS M/M 63-3-1, OPS GOOD.SDR RAAA00E9031Battery · dischargedEMERGENCY LIGHTS WERE INADVERTENTLY LEFT ON AND DISCHARGED EMERGENCY FLOOR PROXIMITLY LIGHTS AT ROW 9CE, ROW 13CDE, AND ROW 21CDE. REPLACED BATTERIES AND OPS CHECKED IAW RAA GMM.SDR RAAA00E9030Battery · dischargedEMERGENCY LIGHTS WERE INADVERTENTLY LEFT ON AND DISCHARGED EMERGENCY EGRESS INDICATORS AT FRONT PAX DOOR, OVERWING EXIT LIGHTS, AND RT AFT EMERGENCY EXIT DOOR. REPLACED BATTERIES AND OPS CHECKED IAW RAA GMM.SDR RAAA00E9029Battery · dischargedDURING SERVICE CHECK, FOUND ROW 3 FLOOR PROXIMITY LIGHT WOULD NOT TEST. REPLACED ROW 3 FLOOR PROXIMITY LIGHT BATTERY, LIGHT TESTS GOOD PER ECO 86-26.SDR RAAA00E9028Skin · crackedDURING SCHEDULED NR 1 MAINT CHECK, FOUND RIGHT NOSE GEAR DOOR INNER SKIN CRACKED AT AFT HINGE MOUNT AREA. CRACK AT FWD EDGE RUNNING VERTICAL. REPAIRED RIGHT NOSE GEAR DOOR IAW LOCKHEED SRM 51-3-7 FIG 1 & 53-2-1 FIG 2 & 51-2-14.SDR RAAA00E9027Battery · dischargedDURING SERVICE CHECK FOUND LT OVERWING EXIT IDENTIFIER FAILED TEST. REPLACED BATTERY AND TESTED IAW RAA GMM.SDR RAAA00E9023Light · inoperativeDURING SERVICE CHECK, FOUND LEFT FWD. PAX DOOR PULL DOWN EMERGENCY LIGHT INOP. REPLACED PULL DOWN EMERGENCY LIGHT AND TESTED IAW RAA GMM.SDR RAAA00E9022Light · inoperativeDURING SERVICE CHECK FOUND AFT LEFT PAX DOOR PULL DOWN EMERGENCY LIGHT INOP . REPLACED PULL DOWN EMERGENCY LIGHT AND TESTED IAW RAA GMMSDR RAAA00E9021Battery · dischargedDURING SERVICE CHECK, FOUND ROW 15 FLOOR PROXIMITY LIGHT WOULD NOT TEST. REPLACED BATTERY, LIGHT TESTS GOOD IAW ECO 86-26 .SDR RAAA00E9026Switch · inoperativeAFTER PUSHBACK FROM BLOCKS AT ANC NR 3 FUEL PRESSURE LOW LIGHT ON DURING HIGH AND LOW RPM . REPLACED NR 3 ENGINE LOW PRESSURE FUEL SWITCH PER L-188 M/M 28-10-0 LEAK AND OPS CHECK GOOD.SDR RAAA000E9024Indicator · failedDURING PUSHBACK FROM BLOCKS IN ANC CAPT ATTITUDE GYRO FAILED . REPLACED CAPT. ADI PER M/M 34-14-11.SDR RAAA00E9025Indicator · failedCAPT ATTITUDE GYROS SHOWS A DIVE WHEN AIRCRAFT IN CLIMB ATTITUDE, FOUND AFTER DEPARTURE IN ANC . REPLACED CAPT ADI PER M/M 34-14-11SDR RAAA00E9020Battery · dischargedDURING SERVICE CHECK, FOUND AFT LEFT PAX DOOR EXIT IDENTIFIER FAILED TEST. REPLACED BATTERY AND TESTED GOOD IAW RAA GMM.SDR RAAA00E9019Switch · failedDEPARTING ANCHORAGE, LT MAIN GEAR INT LIGHT REMAINED ON TIME 1626Z. REPLACED LT UPLOCK SWITCH PER 32-6-0. OP''S CHECKS OK. CYCLED GEAR AND ALL INDICATIONS NORMAL PER L-188 M/M 32-6-0.SDR RAAA00E9018Light · inoperativeFLIGHT STATION EMERGENCY PULL DOWN LIGHT WILL NOT TEST. REPLACED PULL DOWN LIGHT, TESTS GOOD PER RAA GMM.SDR RAAA00E9017Battery · dischargedFWD RT OVERWING EMERGENCY EXIT ID LIGHT WILL NOT TEST. REPLACED BATTERY, TESTS GOOD PER RAA ECO 86-26.SDR RAAOOE9015Battery · dischargedAFT CABIN EMERGENCY EXIT DOOR EXIT IDENTIFIER LIGHT WILL NOT TEST. REPLACED EXIT IDENTIFIER BATTERY PER RAA ECO 86-26.SDR RAAA00E9016Indicator · inoperativeNR 4 TORQUEMETER HP GUAGE INOP. REPLACED NR 4 TORQUEMETER.SDR RAA00E9013Light · inoperativeDURING SCHEDULED #2 CHECK EMERGENCY EXIT LIGHT AT AFT LAVATORY EMERG. EXIT INOP. REPLACED LIGHT AND OPS CHECKED IAW 33-02-0SDR RAAA00E9014Light · inoperativeDURING SCHEDULED #2 CHECK, FOUND EMERGENCY PULL DOWN LIGHT AT LEFT REAR DOOR INOP. REPLACED LIGHT AND OPS CHECKED IAW 33-02-0SDR RAAA00E9012Battery · dischargedDURING SCHEDULED NR 2 CHECK FOUND EMERGENCY EXIT ID LIGHT AT LEFT FRONT DOOR FAILED TEST. REPLACED BATTERY AND TESTED IAW RAA GMM.SDR RAAA00E9011Battery · dischargedDURING SCHEDULED NR 2 CHECK, FOUND OVERWING EMERGENGY LIGHTS VERY DIM. REPLACED BATTERY AND OPS CHECKED IAW 33-20-0.SDR RAAA00E9010Battery · dischargedDURING SCHEDULED NR 2 CHECK, FOUND EMERGENCY EXIT ID LIGHT AT ROW 12 AB FAILS TEST. REPLACED BATTERY AND TESTED IAW RAA GMM.SDR RAAA00E9009Sign · defectiveDURING SCHEDULED NR 2 CHECK FOUND EMERGENCY EXIT INDICATOR AT ROW 16 CDE INOP. REPLACED LIGHT AND OPS CHECKED IAW 33-2-0.SDR RAAA00E9008Dome Nut · corrodedLEAKING DOME NUT, WING TO NACELLE FILLET, NR 3 PLANK UPPER SURFACE. REMOVED DOME NUT, INSPECTION FOR CORROSION FOUND BEYOND LIMITS. REMOVED CORROSION IAW LAC SRM 57-2-1. INSTALLED REPAIR IAW LAC DRAWING 841880. ALODINED AND PRIMED IAW SRM 51-2-14.SDR RAAA00E9007Panel · crackedDURING SCHEDULED NR 2 CHECK, RT WING FOUND CORROSION CRACKING-PLANK SEPARATION AT INBOARD SKATE ANGLE NR 3 NACELLE NR 7 PLANK LOWER SURFACE. REMOVED CORROSION, INSTALLED REPAIR IAW LKHEED/ELEC SRM 57-2-1, 51-2-12 & 51-2-14.SDR RAAA00E9006Bearing Support · brokenFIRE ALARM AND BELL DURING START NR 4 ENGINE, ALL ZONES. REAR TURBINE BEARING SUPPORT TO BE REPLACED PRIOR TO NEXT FLIGHT.SDR RAAA00E9005Battery · dischargedEMERGENCY AISLE LIGHT AT ROW 13CDE FAILS TO TEST. REPLACED BATTERY ANDS OPS CHKD IAW RAA GMM.SDR RAAA00E9004Housing · crackedEMERGENCY INDICATOR LIGHT LENS SEPERATED FROM HOUSING AND HOUSING IS CRACKED, LOCATED AT AFT LEFT PASSENGER DOOR. REPLACED LIGHT, INSTALLED NEW BATTERY, AND OPS CHKD IAW RAA GMM.SDR RAAA00E9003Battery · dischargedEMERGENCY LIGHT AT ROW 16 CDE INOP. REPLACED BATTERIES AND OPS CHECKED IAW RAA GMM.SDR RAAA00E9002Battery · dischargedAFT CABIN DOOR EXIT IDENTIFIER LIGHT WILL NOT TEST. REPLACED EXIT ID BATTERY, LIGHT TESTS GOOD PER RAA ECO 86-26.SDR RAAA00E9001Battery · dischargedEMERGENCY LIGHT AT ROW 16 CDE INOP. REPLACED BATTERIES AND OPS CHECKED IAW RAA GMM.SDR RAAA99E9031Light · inopEMERGENCY LIGHT AT ROW 16 C, D, E, WILL NOT TEST. REPLACED LIGHT ASSEMBLY.SDR RAAA99E9030Battery Pack · dischargedEMERGENCY LIGHT AT ROW 3 C, D, E, WILL NOT TEST. REPLACED BATTERY PACK.SDR RAAA99E9029Battery Pack · dischargedEMERGENCY PROXIMITY LIGHT AT ROW 21 CDE, DOES NOT TEST. REPLACED BATTERY PACK.SDR RAAA99E9028Battery Pack · dischargedEMERGENCY PROXIMITY LIGHTAT ROW 9 CDE DOES NOT TEST. REPLACED BATTERY PACK.SDR RAAA99E9027Antenna · damagedDURING APPROACH TO ANC, AIRCRAFT STRUCK BY LIGHTNING, G/S ANTENNA DAMAGED. REPLACED G/S ANTENNA. OPS CHECKED PER LAC MM 34-13-13.SDR RAAA99E9026Radome · damagedDURING APPROACH TO ANC, AIRCRAFT STRUCK BY LIGHTNING. RADOME RECEIVED DAMAGE. REPAIRED PER SRM 53-1-6 NEGLIGIBLE DAMAGE.SDR RAAAE9025Battery Pack · dischargeFORWARD CABIN EXIT ID LIGHT WILL NOT TEST. REPLACED BATTERY.SDR RAAA99E9024Battery Pack · dischargedPAX ROW 17 CDE WILL NOT TEST. REPLACED BATTERY.SDR RAAA99E9023Skin · damagedDURING SERVICE CHECK FOUND FUSELAGE SKIN DENTED AND DEEP GOUGE AT FS 303 BETWEEN STRINGERS 49 AND 50 LEFT HAND. SKIN DAMAGE CUT OUT FROM FS 302.5 TO 304 X 1 HEIGHT BETWEEN STRINGERS 49 AND 50 AND INSTALLED AN EXTERNAL DOUBLER IAW SRM 53-2-1 FIGURE 2 SHEET 3.SDR RAAA99E9022Battery Pack · dischargedPAX ROW 12 FLOOR PROXIMITY EGRESS LIGHT FAILED SERVICE CHECK. CHANGED BATTERY PACK DUE DISCHARGED.SDR RAAA99E9021Light · inoperativeFORWARD PAX DOOR PULL DOWN EMERGENCY LIGHT FAILED SERVICE CHECK. CHANGED LIGHT ASSEMBLY.SDR RAAA99E9020Frame · corrodedDURING SCHEDULED NR 2 CHECK, FOUND FS 920 FRAME CORRODED FROM STR 34 TO 39 ON INSIDE FLANGE BETWEEN FRAMES. CUT OUT CORRODED AREA OF FRAME AND INSTALLED SPLICE IAW SRM 53-2-3, TREATED AND PRIMED.SDR RAAA99E9019Sign · failedFWD CABIN EMERGENCY EXIT EGRESS IDENTIFIER LIGHT FAILED SERVICE CHECK. CHANGED LIGHT ASSEMBLY DUE FAILED.SDR RAAA99E9033Engine · low powerAPM 2.0 IN-FLT MONITORING INDICATES PAST 7 FLIGHTS PERCENT EFF AVG 89.3 PERCENT EQUALS .9 PERCENT BELOW ALERT LEVEL NR 2 ENGINE. REPLACED NR 2 ENGINE.SDR RAAA99E9018Light · failedPAX ROW 13 FLOOR PROXIMITY EGRESS LIGHT FAILED SERVICE CHECK. CHANGED LIGHT ASSY DUE FAILED.SDR RAAA99E9017Sign · failedAFT RT OVERWING EMERGENCY EXIT EGRESS IDENTIFIER LIGHT FAILED SERVICE CHECK. CHANGED LIGHT ASSY DUE FAILED, POOR RECEPTION.SDR RAAA99E9016Battery Pack · dischargedFLIGHT CREW REPORTED EMERGENCY LIGHTS ON AND UNABLE TO DISARM. CHANGED 4 FLOOR PROXIMITY EGRESS LIGHT BATTERIES DUE DISCHARGED.
Back to N1968R, cancelled Feb 21, 2001