Service difficulty reports · 26
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N2269A' AND deregistration_id = 'N2269A-2004-08-28' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N2269A' AND deregistration_id = 'N2269A-2004-08-28' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HEEA061730Encoder · failedALTIMETER ENCODER NOT FUNCTIONING.SDR HEEA060831Torque Gauge · reads lowTORQUE GAUGE READS LOW.SDR HEEA060675Sensor · defectiveFLOAT LEAKING. UNIT WAS PURCHASED ON 6-7-89.SDR HEEA0015725Tank Unit · out of toleranceTRANSMITTER IN FUEL TANK TRANSMITS HIGH OUT OF TOLERANCE.SDR HEEA0015344Mount · failedCAUSED YELLOW TEMP INDICATOR ON INPUT SHAFT TO TURN BLACK.SDR HEEA0012961Regulator · defectiveVOLTS REG DEFECTIVE. NOT ADJUSTABLE ABOVE 270 FEET.SDR HEEA0012850Actuator · failedACTUATOR MOTOR WILL NOT RUN.SDR HEEA0012352Valve · failedVALVE STAYS OPEN INTERMITTENTLY.SDR HEEA0012098Fuel Pump · leakingFUEL LEAKING FROM SEAL DRAIN.SDR HEEA0011270Beacon · wont testBEACON WILL NOT TEST.TIME SINCE REPAIR 253:50.SDR HEEA0010276Transceiver · inoperativeMODE "C" INOPERATIVE. PERFORMED PRELIMINARY INSPECTION, TESTED, ADJUSTED PULSE WIDTH AND FREQUENCY. REPLACED MISSING PHOTOCELL LENS P/N 088-00655-0000. BENCH CHECK GOOD.SDR HEEA0010227Indicator · precessesATTITUDE INDICATOR PRECESSES EXCESSIVELY.SDR HEEA0010226Indicator · failedATTITUDE INDICATOR WOULD NOT ERECT.SDR HEEA0010183Actuator · failedACTUATOR DOES NOT OPERATE.SDR HAIHEEA9712Airspeed Ind · leaksAIRSPEED INDICATOR LEAKS DURING STATIC SYSTEM CHECK.SDR HEEA979063Transponder · inoperativeTRANSPONDER MODE C INOPERATIVE. PERFORMED PRELIMINARY INSPECTION. FOUND POWER OUT LOW, ADJUSTED V101. NO HELP. REPLACED V101 CAVITY TUBE P/N C2080A. REPAIRED. BENCH CHECK GOOD.SDR HEEA967499Scroll Assy · oversizeUPON PRE-ASSEMBLY INSPECTION OF PART NOTED THE FOLLOWING: I.D. OVERSIZED ON SCROLL PROBE ELBOW BORE AS MARKED. REPLACED DISCREPANT PART. PART RETURNED TO DALLAS AIRMOTIVE FOR 100% WARRANTY REPAIR PER ROB HALDEMEN'S INSTRUCTIONS.SDR HEEA967431Transceiver · failedWILL NOT REPORT. FOUND UNIT DRAWS EXCESSIVE CURRENT. REPLACED CAVITY OSCILLATOR V101. REPAIRED. ADJUSTED PULSE WIDTH AND FREQUENCY. BENCH CHECK GOOD.SDR HEEA967028Transceiver · defectiveREADOUT STAYS DIM IN BRIGHT LIGHT. FOUND THAT DISPLAY LENS HAD LOST IT'S TINT. REPLACED DISPLAY LENS - REPAIRED PROBLEM. ADJUSTED SIDETONE. BENCH CHECK GOOD.SDR HEEA966954Servo · leakingSERVO LEAKING AT PISTON SHAFT.SDR HEEA966953Servo · leakingSERVO LEAKING AT PISTON SHAFT.SDR HEEA966351Strap · crackedPART IS CRACKED. AFT CABIN OVERHEAD BOX BEAM R/H STRAP P/N 206-031-200-076 CRACKED OUT AT CENTER R/H SUPPORT. INSTALLED NEW STRAP ASSEMBLY.SDR HEEA956155Transceiver · defectiveTWO YEAR INSPECTION REQUIRED. FOUND V101 CAVITY OSCILLATOR WEAK AND V301 PHOTODETECTOR INOPERATIVE. REPLACED BOTH ITEMS. ADJUSTED POWER OUT AND FREQUENCY TO SPECS. BENCH CHECK GOOD.SDR HEEA956119Spar Assy · corrodedSPAR ASSY IS CORRODED. (CORROSION AND WORN BEYOND LIMITS) REPLACED WITH SERVICEABLE SPAR ASSY.SDR HEEA956042Fitting · mis mfgPILOT HOLES ON VERTICAL FLANGE OF FITTING DO NOT ALIGN WITH EXISTING FASTENER HOLES ON BOX BEAM.SDR HEEA955970Crosstube · corrodedCROSSTUBE IS CORRODED. (CORROSION AT MOUNT PAD .011 BEYOND LIMITS.)