N228AA, cancelled Jun 3, 2009

Service difficulty reports · 33

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N228AA' AND deregistration_id = 'N228AA-2009-06-03'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA20060650Pump · failedDFW - IAH TO ORD - FUEL WOULD NOT FEED FROM CENTER TANK. LANDED DFW WITHOUT INCIDENT. FOUND AFT CENTER TANK FUEL BOOST PUMP CIRCUIT BREAKER TRIPPED. REPLACED BOTH CENTER FUEL BOOST PUMPS. SYSTEM GROUND CHECKED NORMAL OPERATION.Sep 4, 2006 · N228AA · Doug DC982 · Fuel Boost PumpSDR AALA20050691Wire · brokenSFO - DURING OVERNIGHT MAINTENANCE FOUND EMERGENCY CEILING LIGHTS ROWS 23-26 INOPERATIVE. REPAIRED BROKEN WIRE AT EMERGENCY POWER SUPPLY AT ROW 26 RIGHT HAND SIDE. SYSTEM GROUND CHECKED NORMAL OPERATION.Oct 19, 2005 · N228AA · Doug DC982 · Emergency LightingSDR AALA20050632Battery Pack · inoperativeSAT - AFT OVERWING AND OVERHEAD EMERGENCY LIGHTS AT ROWS 24 - 28 INOPERATIVE. REPLACED EMERGENCY LIGHT BATTERY PACK FOR AFT OVERWING AND OVERHEAD EMERGENCY LIGHTS FOR ROWS 24 - 28. SYSTEM GROUND CHECKED NORMAL OPERATION.Oct 2, 2005 · N228AA · Doug DC982 · Emergency LightingSDR AALA20050067Wire · brokenTPA - EMERGENCY EXIT LIGHT AT FORWARD GALLEY AISLE WALL INOPERATIVE. REPAIRED BROKEN WIRE IN AISLE FLOOR TRACK FOR EMERGENCY EXIT LIGHT AT FORWARD GALLEY AISLE WALL. SYSTEM GROUND CHECKED NORMAL OPERATION.Jan 31, 2005 · N228AA · Doug DC982 · Light System WiringSDR AALA20050030Battery Pack · dischargedLAX - EMERGENCY LIGHTS IN CABIN INOPERATIVE. REPLACED BATTERY PACKS AT B5101, B5100, AND B5105 FOR EMERGENCY LIGHTS IN CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION.Jan 15, 2005 · N228AA · Doug DC982 · Emergency LightingSDR AALA20040972Connector · looseDFW - TAIL CONE RELEASE HANDLE EMERGENCY LIGHT INOPERATIVE. REPINNED TAIL CONE RELEASE HANDLE EMERGENCY LIGHT CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION.Sep 19, 2004 · N228AA · Doug DC982 · Electrical ConnectorsSDR AALA20040325Battery Pack · inoperativeORD EMERGENCY LIGHTS ABOVE ROW 9 INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS ABOVE ROW 9. SYSTEM GROUND CHECKED NORMAL OPERATION.Mar 8, 2004 · N228AA · Doug DC982 · Emergency LightingSDR AALA20040310Battery Pack · inoperativeMIA - EMERGENCY EXIT LIGHTS ABOVE LEFT AND RIGHT HAND OVERWING EXIT INOPERATIVE. RESET BATTERY PACKS FOR EMERGENCY EXIT LIGHTS ABOVE LEFT AND RIGHT HAND OVEWING EXIT. SYSTEM GROUND CHECKED NORMAL OPERATION.Mar 5, 2004 · N228AA · Doug DC982 · Emergency LightingSDR AALA20040026Battery Pack · dischargedEMERGENCY LIGHTS ABOVE ROWS 7, 8, 9 INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT ROWS 7, 8, AND 9. SYSTEM GROUND CHECKED NORMAL OPERATION. --CLOSED--Jan 6, 2004 · N228AA · Doug DC982 · Emergency LightingSDR AALA20031285Engine · malfunctionedIAD T646/14 EN ROUTE MIA-YYZ AIRCRAFT LOST OIL PRESSURE AND QUANTITY IN NUMBER ONE ENGINE. LANDED AT IAD WITHOUT INCIDENT. REPLACED NUMBER ONE ENGINE. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDNov 15, 2003 · N228AA · Doug DC982 · Engine (Turbine/Turboprop)SDR AALA20031115Battery Pack · dischargedAUS - FOUND DURING OVERNIGHT MAINTENANCE, OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT PACK B5-2. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 6, 2003 · N228AA · Doug DC982 · Emergency LightingSDR AALA20030794Clamp · looseFLT 528 - DFW-ATL - TAIL COMPARTMENT HIGH TEMP LIGHT CAME ON 3 TIMES DURING CLIMB-OUT. AIRCRAFT RETURNED DFW AND LANDED WITHOUT INCIDENT. MAINTENANCE DISCOVERED CLAMPS THAT SECURE THE EIRHG TRIM AIR VALVE TO BE LOOSE. RESECURED THE ASSOCIATED V-BAND CLAMPS.Jul 24, 2003 · N228AA · Doug DC982 · Air Distribution SystemSDR AALA20030254Fan · malfunctionedSTL - FLT 2216 - EN ROUTE TUL-STL, SHORTLY AFTER TAKEOFF, FLIGHT ATTENDANT REPORTED SMOKE AND FUMES IN THE CABIN. PILOTS TURNED OFF RECIRCULATION FAN AND RIGHT PACK AND SMOKE DISSIPATED. LANDED IN STL WITHOUT FURTHER INCIDENT. ACCOMPLISHED CABIN ODOR TROUBLFeb 27, 2003 · N228AA · Doug DC982 · Air Distribution FanSDR AALA20030238Skin · crackedTUL - FOUND THREE CRACKS EXTENDING FROM FASTENER HOLE IN FUSELAGE SKIN LT SIDE STATION 1380 BETWEEN LONGERONS 13L AND 14L. STOP DIRLLED CRACKS AND INSTALLED DOUBLER PER SRM 53-01-00 FIG 2 SHEET 3. (M)Feb 21, 2003 · N228AA · Doug DC982 · Fuselage Main, Plate/SkinSDR AALA20030237Skin · crackedTUL - FOUND TWO .25 INCH CRACKS EXTENDING FROM FASTENER HOLE IN FUSELAGE SKIN RIGHT SIDE STATION 1380 BETWEEN LONGERONS 13R AND 14R. STOP DRILLED CRACKS AND INSTALLED DOUBLER PER SRM 53-01-00 FIG 2 SHEET 3. (M)Feb 21, 2003 · N228AA · Doug DC982 · Fuselage Main, Plate/SkinSDR AALA20030189Battery · inoperativeSAN - DURING OVERNIGHT MAINTENANCE, AFT HALF OF SEAT MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED EMERGENCY EXIT LIGHTS BATTERY. SYSTEM GROND CHECKED NORMAL OPERATION. (M)Feb 9, 2003 · N228AA · Doug DC982 · Emergency LightingSDR AALA20020596Boot · blownDFW - FLT 1191 - EN ROUTE DFW-SMF - APPROXIMATELY 10 MINUTES AFTER TAKEOFF, CLIMBING THROUGH 17,000 FEET TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED. ACCOMPLISHED CHECKLIST AND AFTER ABOUT 3.5 MINUTES WITH PACKS IN HP BLEED OFF AND POWER REDUCED FOR LMay 1, 2002 · N228AA · Doug DC982 · Air Distribution SystemSDR AALA20011592Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY PATH LIGHTING IN LOWER TAIL CONE INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 5, 2001 · N228AA · Doug DC982 · Emergency LightingSDR AALA20011452Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, AFT OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED BATTERY FOR AFT OVERWING EXIT SIGN. SYSTEM GROUND CHECK NORMAL OPERATION. (M)Jul 19, 2001 · N228AA · Doug DC982 · Emergency LightingSDR AALA20011451Battery Pack · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, CEILING MOUNTED EMERGENCY EXIT LIGHT AT ROW 13 THROUGH 16 INOPERATIVE. REPLACED CEILING MOUNTED EMEREGNCY EXIT LIGHT BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jul 19, 2001 · N228AA · Doug DC982 · Emergency LightingSDR AALA20011183Clamp · defectiveLAX - FLT 335 - EN ROUTE LAX-SJD - SHORTLY AFTER TAKEOFF TAIL COMPARTMENT HIGH TEMPERATURE LIGHT ILLUMINATED. RETURNED LAX AND LANDED WITHOUT FURTHER INCIDENT. REPLACED LEFT SIDE AUGMENTATION VALVE CLAMP. LEAK CHECKS GOOD. SYSTEM GROUND CHECKED NORMAL OPERMay 30, 2001 · N228AA · Doug DC982 · Pneumatic SystemSDR AALA20011082Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY CEILING LIGHTS FROM ROWS 26 THROUGH 29 DIM. REPLACED BATTERY PACK FOR EMERGENCY CEILING LIGHTS AT ROW 26 THROUGH 29. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)May 15, 2001 · N228AA · Doug DC982 · Emergency LightingSDR AALA20001609Connector · failedOMA - FLT 2463 - EN ROUTE OMA-DFW, SHORTLY AFTER TAKEOFF PILOTS REPORTED SMOKE IN THE COCKPIT AND CABIN THAT CONTINUED TO GET WORSE. RETURNED TO OMA AND LANDED WITHOUT INCIDENT. REPLACED RUBBER HOSE CONNECTORS AT MAIN DISTRIBUTION DUCT IN ROWS 25 TO 30 REPLASep 27, 2000 · N228AA · Doug DC982 · Air Distribution SystemSDR AALA20001321Wire · brokenORD - FLT DURING OVERNIGHT MAINTENANCE, AFT AIRSTAIR EMERGENCY LIGHT INOPERATIVE. REPAIRED WIRE. SYSTEM GROUND CHECK NORMAL OPERATION. (M)Aug 9, 2000 · N228AA · Doug DC982 · Light System WiringSDR AALA990041Apu · leakingMIA - FLT 1246 - EN ROUTE MIA-LGA - ABOUT 3 TO 4 MINUTES AFTER TAKEOFF, EXPERIENCED SMOKE IN CABIN AT 3,000 FEET. ACCOMPLISHED AIR CONDITIONING SMOKE AND FUMES EMERGENCY PROCEDURE. SMOKE APPEARED TO BE COMING FROM AIR CONDITIONING SYSTEM. RETURNED AND MADE Jan 7, 1999 · N228AA · Doug DC982 · Airborne Auxiliary Power Unit (APU) SystemSDR AALA982067Connector · failedDFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR PATH LIGHTING AT FIRST CLASS GALLEY INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHT STRIP FLAP CONNECTOR AT FIRST CLASS GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Nov 11, 1998 · N228AA · Doug DC982 · Emergency LightingSDR AALA981243Frame · crackedTUL - FOUND FRAME 420 BELLFRAME CRACKED AT HORIZONTAL DOOR FRAME STIFFENER ATTACH POINT HI-LOK STRINGER 20R, VIEWED FROM UNDER SIDE OF COLLAR. INSTALLED DOUBLER AND FILLER AND FASTENERS PER SRM 53-10-4. (M)Jun 19, 1998 · N228AA · Doug DC982 · Fuselage Main, FrameSDR AALA980584Longeron · corrodedTUL - FOUND L30 HAS CORROSION STATION 370 TO 427. INSTALLED DOUBLER STRAP PER ESO 80559, DATED 3/19/98. (M)Mar 19, 1998 · N228AA · Doug DC982 · Fuselage Main, Longeron/StringerSDR AALA980545Longeron · corrodedTUL - FOUND CORROSION IN L29L, STATION 370 TO 427. INSTALLED STRAP DOUBLER PER ESO 80559. (M)Mar 19, 1998 · N228AA · Doug DC982 · Fuselage Main, Longeron/StringerSDR AALA980282Acm · defectiveDFW - FLT 2076 - IAH-DFW - SHORTLY AFTER TAKEOFF A BURNING SMELL LIKE A DIRTY PACK SOCK WAS IN COCKPIT AND AFT CABIN. CAIBN FROM MID TO AFT HAD A HAZE IN IT. HAZE AND SMELL QUICKLY DISSIPATED. APU WAS OFF. NO FURTHER SMELL OR HAZE FOR REST OF FLIGHT. LANDFeb 24, 1998 · N228AA · Doug DC982 · Cabin Cooling SystemSDR AALA970823Fan · defectiveBNA - FLT 0839 - EN ROUTE ORF/DFW DURING CRUISE, ACRID ODOR NOTED IN CABIN. AIRCRAFT DESCENDED TO FL 100 AND INTENTIONALLY DEPRESSURIZED AND ODOR SUBSIDED. AIRCRAFT DIVERTED TO BNA AND LANDED WITHOUT INCIDENT. PLACARDED GASPER RE-CIRCULATION FAN INOPERATIVEApr 26, 1997 · N228AA · Doug DC982 · Air Distribution FanSDR AALA960481Wire · defectiveDFW - DURING OVERNIGHT CHECK, FOUND EMERGENCY EXIT FLOOR PATH LIGHTING IN THE FORWARD CABIN AND MAIN CABIN DIM. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHTING WIRE BETWEEN FIRST CLASS AND MAIN CABIN. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)Mar 26, 1996 · N228AA · Doug DC982 · Light System WiringSDR AALA960479Wire · defectiveDFW - DURING OVERNIGHT CHECK, FOUND EMERGENCY EXIT FLOOR PATH LIGHTING IN THE FORWARD CABIN DIM. REPLACED CONNECTOR WIRE. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)Mar 26, 1996 · N228AA · Doug DC982 · Light System Wiring
Back to N228AA, cancelled Jun 3, 2009