N232AA, cancelled Jan 3, 2018
Service difficulty reports · 23
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N232AA' AND deregistration_id = 'N232AA-2018-01-03' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N232AA' AND deregistration_id = 'N232AA-2018-01-03' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA200802222Light · inoperativeSTL EMERGENCY LIGHTS AT OVERHEAD SEAT ROWS 13 TO 16 AND BETWEEN AFT LAVATORIES STAYED ON WHEN ALL POWER REMOVED FROM ACFT. RESET EMERGENCY LIGHT SYSTEM AND CHARGED. SYSTEM GROUND CHECKED NORMAL OPS.SDR AALA200801957Connector · looseORD EMERGENCY LIGHTS AT OVERHEAD LT & RT HAND OVERWING EXITS INOPERATIVE. SECURED LOOSE CONNECTOR AT B1 103 FOR EMERGENCY LIGHTS AT OVERHEAD LT & RT HAND OVERWING EXITS. SYSTEM GROUND CHECKED NORMAL OPS. (CLOSED)SDR AALA200801956Lens · missingORD EMERGENCY LIGHT MISSING LENS IN CABIN. REPLACED LENS FOR EMERGENCY LIGHT IN CABIN. SYSTEM GROUND CHECKED NORMAL OPS. (CLOSED)SDR AALA200800461Controller · inoperativeDFW INFLIGHT T2459/01MAR - LEFT AIR CONDITIONING PACK TEMPERATURE HIGH INDICATION AND PNEUMATIC PRESSURE MAXED OUT. RETURNED TO DFW AND LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE FOR EVALUATION. REPLACED TEMPERATURE SENSOR AND CONTROLLER. FOUNDSDR AALA200800327Wire · looseLGA - EMERGENCY LIGHT AT SEAT 27D INOPERATIVE. SECURED WIRE FOR EMERGENCY LIGHT AT SEAT 27D. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20060681Lens · brokenDFW - EMERGENCY TAIL CONE HANDLE LIGHT LENS BROKEN. REPLACED TAIL CONE HANDLE EMERGENCY LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20060181Battery Pack · inoperativeSFO - EMERGENCY EXIT SIGNS AT ROW 20 LEFT AND RIGHT SIDE INOPERATIVE. REPLACED BATTERY PACK BS 103 FOR EMERGENCY EXIT SIGNS AT ROW 20 LEFT AND RIGHT SIDE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20060016Tire · failedNR FOUR TIRE WAS BLOWN UPON LANDING. FOUND NUMBER FOUR BRAKE ASSEMBLY BAD. REPLACED THE NUMBER FOUR BRAKE ASSEMBLY, THE NUMBER THREE AND FOUR MAIN LANDING GEAR WHEEL ASSEMBLY, AND RIGHT HAND MAIN LANDING GEAR SPRAY DEFLECTOR. SYSTEM GROUND CHECKED NORMAL OPSDR AALA20041223Battery Pack · dischargedDFW - EMERGENCY LIGHTS IN TAIL CONE COMPARTMENT INOPERATIVE. REPLACED BATTERY PACK/CHARGER ASSEMBLY FOR EMERGENCY LIGHTS IN TAIL CONE COMPARTMENT. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040955Battery · inoperativeDEN - EMERGENCY LIGHTS FROM 3DE TO 20DEF INOPERATIVE. REPLACED FORWARD BATTERY FOR EMERGENCY LIGHTS FROM 3DE TO 20DEF. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040683Release Mech · inoperativeLAX - TAIL CONE FAILED TO RELEASE. ADJUSTED TAIL CONE RELEASE SYSTEM. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040564Slide · unserviceablePHX - FORWARD SERVICE DOOR SLIDE PRESSURE BELOW GREEN ARC. REPLACED SLIDE AT FORWARD SERVICE DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040162Latch · inoperativeIAH - INFLIGHT T1428/31, GEAR DOWN WOULD NOT RETRACT AFTER TAKEOFF. CREW RETURNED GEAR HANDLE TO DOWN POSITION AND FLEW GEAR DOWN TO DFW. LANDED WITHOUT INCIDENT. REPLACED GEAR DOOR BYPASS HANDLE LATCH ASSEMBLY AND RIGHT MAIN LANDING GEAR DOOR ASSEMBLY. SYSDR AALA20031298Battery Pack · dischargedLAX INTERIOR CEILING EMERGENCY LIGHTS BETWEEN ROWS 18-21 INOPERATIVE. REPLACED BATTERY PACK FOR INTERIOR CEILING EMERGENCY LIGHTS BETWEEN ROWS 18-21. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031297Battery Pack · dischargedLAX FORWARD LEFT HAND OVERWING INTERIOR EMERGENCY LIGHT INOPERATIVE. REPLACED FORWARD LEFT HAND OVERWING INTERIOR EMERGENCY LIGHT BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20021599Hydraulic System · leakingDFW - FLT 598 - DURING TAXI AIRCRAFT FILLED WITH SMOKE ACCOMPANIED BY A DIRTY SOCK SMELL. AIRCRAFT TAXIED TO GATE WITH NO FURTHER INCIDENT. FOUND HYDRAULIC LEAK AT LEFT ENGINE HYDRAULIC SYSTEM. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20020805Stringer · dentedTUL - FOUND STRINGER IS DENTED FROM SKIN DAMAGE AT INSIDE, FORWARD AREA OF HORIZONTAL L/E, RIGHT SIDE MIDDLE LOWER SECTION MIDDLE PLANK. REPAIRED PER ESO 80559 DATED 5/20/02. (M)SDR AALA20020804Structure · crackedTUL - FOUND RIGHT HORIZONTAL STABILIZER, MID LOWER SECTION, MIDDLE PLANK HAS APPROX 6 INCHES DAMAGED AREA WITH CRACK. REPAIRED PER ESO 80559 DATED 5/20/02. (M)SDR AALA991235Sensor · out of adjustDFW - FLT 751 - EN ROUTE TUL-DFW, LEFT MAIN LANDING GEAR LIGHT ILLUMINATION WITH GEAR HANDLE IN UP POSITION. AIRCRAFT LANDED DFW WITHOUT INCIDENT. ADJUSTED LEFT MAIN LANDING GEAR UPLOCK SENSOR. ACCOMPLISHED GEAR SWING. SYSTEM GROUND CHECKED NORMAL OPERATIOSDR AALA981015Angle · corrodedTUL - CUSP ANGLE MEMBRANE CORRODED BENEATH FORWARD SERVICE DOOR PANEL. INSTALLED NEW SECTION OF CUSP ANGLE PER SRM 53-05, FIG 55. (M)SDR AALA981014Floor Support · corrodedTUL - FLOOR SUPPORT CORRODED, BS 200. DRAWING ON SRM 51-10-3. CUT OUT CORRODED SECTION, BLENDED AIND INSTALLED DOUBLER PER AARD 53-00-00-2. (M)SDR AALA972306Fan · defectiveORD - FLT 798 - EN ROUTE LAX/ORD DURING CRUISE, ELECTRICAL ODOR NOTED IN CABIN. AIRCRAFT PROCEEDED TO ORD AND LANDED WITHOUT INCIDENT. REPLACED CABIN RECIRCULATION FAN. SYSTEM GROUND CHECKED, NORMAL OPERATION WITH NO ODOR NOTED. (X)SDR AALA970323Connector · looseDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BY FORWARD LAVATORY INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT STRIP CONNECTOR BY FORWARD LAVATORY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
Back to N232AA, cancelled Jan 3, 2018