N285AA, cancelled Nov 6, 2008
Service difficulty reports · 20
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N285AA' AND deregistration_id = 'N285AA-2008-11-06' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N285AA' AND deregistration_id = 'N285AA-2008-11-06' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20031224Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, FOUND EMERGENCY CEILING LIGHTS OVER ROWS 18 THROUGH 21 INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY CEILING LIGHTS OVER ROWS 18 THROUGH 21. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20031225Connector · looseDFW - DURING OVERNIGHT MAINTENANCE, FOUND TAIL CONE AREA EMERGENCY LIGHTS INOPERATIVE. REPAIRED LOOSE BATTERY CONNECTION FOR TAILCONE AREA EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20031147Battery Pack · inoperativeMAINTENANCE OBSERVED OVERWING EXIT LIGHTS INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20031065Battery Pack · dischargedDTW - FOUND DURING OVERNIGHT MAINTENANCE EMERGENCY ESCAPE PATH LIGHTING WAS OBSERVED TO BE INOPERATIVE IN THE AFT TAIL EXIT. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20021887Battery · not seatedDFW - DURING OVERNIGHT MAINTENANCE, AFT CABIN OVERHEAD EMERGENCY EXIT LIGHTS INOPERATIVE. RESEATED EMERGENCY EXIT LIGHT BATTERY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20020822B-Nut · looseLAS - FLT 1236 - WHILE TAXIING AT LAS, CABIN AND COCKPIT FILLED WITH SMOKE, PERFORMED EMERGENCY EVACUATION. TURNED OFF APU SMOKE STOPPED. SECURED LOOST B-NUT AT LEFT THRUST REVERSER. CLEANED ACCUMULATOR AREA. ACCOMPLISHED PACK BURN OUT. SYSTEM GROUND CHECSDR AALA20020428Connector · looseORD - DURING OVERNIGHT MAINTENANCE, AFT SECTION EMERGENCY EXIT LIGHTS FORWARD OF AFT DOOR INOPERATIVE. RESECURED EMERGENCY EXIT LIGHT CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20020154Odor · detectedDFW - FLT 641 - EN ROUTE DFW-YYC, SHORTLY AFTER TAKEOFF, SMOKE WAS REPORTED IN CABIN. EMERGENCY DECLARED, RETURNED DFW AND LANDED WITHOUT INCIDENT. REPLACED RIGHT PACK PRIMARY AND SECONDARY HEAT EXCHANGER. REPLACED APU, AND ACCOMPLISHED PACK BURN OUT. NO SSDR AALA20020153Coalescer Bag · contaminatedDFW - FLT 515 - EN ROUTE DFW-COS, SHORTLY AFTER TAKEOFF, HEAVY SMOKE WAS REPORTED IN CABIN. EMERGENCY DECLARED, RETURNED DFW AND LANDED WITHOUT INCIDENT. ACCOMPLISHED PACK BURN OUT. NO SMOKE OR ODORS NOTED. PRECAUTIONARY REPLACED COALESCER BAGS. SYSTEM GRSDR AALA20011308Valve · leakingCLT - FLT 1855 - EN ROUTE CLT-DFW - ON CLIMB-OUT, DETECTED LEFT SIDE ENGINE STALL. RETURNED CLT AND LANDED WITHOUT FURTHER INCIDENT. REPLACED LEFT SIDE ENGINE. REPLACED LEFT SIDE FUEL P AND D VALVE. ACCOMPLISHED LEAK CHECK. NO LEAKS NOTED. SYSTEM GROUND SDR AALA991769Rectifier · failedORD - FLT 2378 - EN ROUTE DFW-ORD, NUMBER ONE LOAD INDICATOR READ ZERO LOAD AND NUMBER TWO LOAD INDICATOR READ .8 LOAD. BURNING SMELL NOTED AND DC BUS TIE WAS CLOSED. SMELL DISSIPATED AND K1 CIRCUIT BREAKER WAS POPPED. REPLACED NUMBER 1 TRANSFORMER RECTIFIESDR AALA991577Wire · cutDFW - DURING OVERNIGHT MANTENANCE, AFT CEILING EMERGENCY EXIT LIGHT INOPERATIVE. SPLICED WIRES TO AFT CEILING EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA991239Skin · damagedTUL - FUSELAGE SKIN NICK AND GOUGED THROUGH AREA RIGHT OF LONGERON 1 STATION 1070-1110 AFT OF TEAR DROP ANTENNA. BLENDED DAMAGED AREAS STATION 1070 AND 1110, WITHIN LIMITS. BLENDED GOUGED STATION 1090 OUT OF LIMITS. INSTALLED DOUBLER PER SRM 53-04 PAGE 218FSDR AALA991238Longeron · crackedTUL - FOUND LONGERON 4 LEFT SPLICE FS 160 PLUS 9 INCHES TO REPAIR CRACK IN LONGERON AT 4 LEFT FS 160. REPAIR PER SRM 53-02 FIG 18. (M)SDR AALA991240Seat Track · corrodedTUL - NR 4 SEAT TRACK CORRODED. REPAIRED SEAT TRACK WITH PLUG REPAIR AS PER SRM 53-05 PART 1. (M)SDR AALA980963Light · misinstalledORD - DURING OVERNIGHT MAINTENANCE, FORWARD GALLEY SERVICE DOOR EMERGENCY EXIT LIGHT IS INTERMITTENT. RECONNECTED FORWARD LIGHT STRIP CORRECTLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA980704Conductor · corrodedSFO - DURING OVERNIGHT MAINTENANCE CHECK, EMERGENCY FLOOR PATH LIGHTING FROM SEAT ROW 25 DEF THROUGH FIRST CLASS FOUND INOPERATIVE. REPLACED CORRODED SECTION OF EMERGENCY EXIT PATH LIGHT STRIP CONDUCTOR ASSEMBLY AT SEAT ROW 3 EF. SYSTEM GROUND CHECKED, NORMASDR AALA961865Strip · defectiveDFW - DURING OVERNIGHT CHECK, FOUND EMERGENCY EXIT FLOOR PATH LIGHTING AT AFT OF PLANE INOPERATIVE. REPLACE EMERGENCY EXIT FLOOR PATH LIGHT STRIP AT AFT OF PLANE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA960109Cusp · corrodedTULE - FOUND CUSP CORRODED LOWER SURFACE, STATION 1175 UNDER NR 1 SEAT TRACK. INSTALLED DOUBLER PER SRM 53-01 PAGE 7 FIGURE 2 SHEET 2. (M)SDR AALA960060Support · corrodedTULE - FOUND CORROSION ON FLOOR BOARD SUPPORT IN AFT CARGO COMPARTMENT AT STATION 1212, WHERE BOLTED TO RIGHT FRAME. INSTALLED NEW FLOOR BOARD SUPPORT. (M)
Back to N285AA, cancelled Nov 6, 2008