N288SC, cancelled Aug 5, 2008
Service difficulty reports · 144
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N288SC' AND deregistration_id = 'N288SC-2008-08-05' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N288SC' AND deregistration_id = 'N288SC-2008-08-05' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA97161Duct · crackedLEFT PACK UNABLE TO MAINTAIN CABIN PRESSURE AT FL 240, DESCENDED TO 10,000 FEET AND CABIN PRESSURE STABILIZED. AIRCRAFT DIVERTED TO ALTERNATE AIRPORT. FOUND CRACKED AIR CONDITIONING DUCT AND TWO LEAKING CHECK VALVES. REPLACED DUCT AND CHECK VALVES, PRESSURISDR SCNA97078Battery · dischargedFORWARD LAV SMOKE DETECTOR BEEPED. REMOVED AND REPLACED BATTERY AND TESTED NORMAL.SDR SCNA97075Bulb · failedL-2 DOOR EMERGENCY SLIDE LIGHT WAS FOUND INOP. REMOVED AND REPLACED BULB AND SYSTEM, FUNCTIONALLY CHECKED NORMAL.SDR SCNA97067C1 Blades · damagedAT APPROXIMATELY 50 FEET, FOD WAS INGESTED INTO THE NUMBER 1 ENGINE, THE ENGINE FAIL LIGHT ILLUMINATED WITH AURAL WARNING, AND THE NUMBER 1 ENGINE N1 FLUCTUATED. REDUCED NUMBER 1 ENGINE POWER TO IDLE AND ALL GAUGES INDICATED NORMAL. FOUND DAMAGE LIMITED TO TSDR SCNA97066Batteries · dischargedAFT AIRSTAIR OVERHEAD EMERGENCY LIGHTS FOUND DIM. REMOVED AND REPLACED BATTERIES AND OPS CHECKED GOOD.SDR SCNA97010Coalescer Bags · contaminatedCREW REPORTED SMOKE IN CABIN. AIRCRAFT RETURNED TO GATE. REPLACED COALESCER BAGS, INSPECTED PNEUMATIC SYSTEM, PERFORMED ENGINE RUNS, AND NO DEFECTS NOTED. FOUND LEFT ACM WITH EVIDENCE OF SEAL LEAKAGE BETWEEN CASE HALVES, REMOVED AND REPLACED ACM. ALSO REMOSDR SCNA97006Light · inoperativeAFT EMERGENCY TRACK LIGHT WAS FOUND INOP. REPLACED PIGTAIL ASSEMBLY, LENS, AND LAMP AND OPS CHECKED GOOD IN ACCORDANCE WITH MM 33-50-00.SDR SCNA97003Bulb · failedFOUND AFT AIRSTAIR EMERGENCY LIGHTS INOP. RELAMPED 3 EMERGENCY LIGHTS AND OPS CHECKED GOOD.SDR SCNA96455Window Seal · not seatedCOULD NOT HOLD PRESSURIZATION IN CABIN AT 25,000 FT, NOISE WAS HEARD AT L1 AND L2 AREA DURING CLIMBOUT. RETURNED TO LAS. RESEATED AND RETORQUED L1 WINDOW, PRESSURIZED AIRCRAFT TO 6.5 PSI IN ACCORDANCE WITH MM 21-31-0 AND NO LEAKS WERE NOTED.SDR SCNA96435Battery Pack · dischargedL2 DOOR EMERGENCY EXIT SIGN INOP. REMOVED AND REPLACED BATTERY PACK FOR L2 DOOR EMERGENCY EXIT SIGN, OPS CHECK GOOD.SDR SCNA96403Frame · corrodedDURING INSPECTION, CORROSION DAMAGE WAS DISCOVERED ON THE FUSELAGE SKIN AT BS 328 RT, JUST OUTBOARD OF THE NLG WHEEL WELL CUTOUT. ALSO, CORROSION WAS FOUND ON THE BS 328 FRAME AND THE LOWER STIFFENER FOR THE NOSE LANDING GEAR WHEEL WELL SIDE PANEL. THE FUSELSDR SCNA96266Smoke Detector · intermittentFORWARD LAVATORY SMOKE DETECTOR TEST BUTTON WAS FOUND INTERMITTENT. REMOVED AND REPLACED SMOKE DETECTOR AND OPS CHECKED GOOD.SDR SCNA96237Skin · crackedFOUND A SMALL CRACK IN SKIN ON THE C3 DOOR, LOWER AFT CORNER. REPAIRED CRACK IN ACCORDANCE WITH SRM 52-20-2.SDR SCNA96222Light · damagedEMERGENCY FLOOR TRACK LIGHTING SPLIT IN SECTION NEXT TO SEAT 5D. REPLACED BAD SECTION OF TRACK LIGHTING. OPS CHECKED OK.SDR SCNA96221Floor Light · splitSECTION OF EMERGENCY FLOOR TRACK LIGHTING SPLIT FROM GALLEY CART TRAFFIC, NEAR AFT GALLEY AREA FORWARD OF 33D. REPLACED BAD SECTION OF TRACK LIGHTING IN AFT GALLEY, OPS CHECKED OK.SDR SCNA96216Smoke Detector · inoperativeRIGHT AFT LAV SMOKE DETECTOR WILL NOT SHUT OFF. REMOVED AND REPLACED THE RIGHT AFT LAV SMOKE DETECTOR, OPS CHECKED GOOD.SDR SCNA96200Lamp · inoperativeFOUND LEFT FORWARD OVERWING EXIT SIGN INTERMITTENT. RELAMPED AND OPS CHECKED NORMAL.SDR SCNA96199Lamp · inoperativeFOUND RIGHT SERVICE DOOR OVERHEAD EXIT SIGN LIGHTS INTERMITTENT. RELAMPED AND OPS CHECKED NORMAL.SDR SCNA96191Power Supply · inoperativeTHE LEFT OVERWING EMERGENCY LIGHT WAS FOUND INOP. REPLACED BATTERY POWER SUPPLY ASSEMBLY AND OPS CHECKED OK.SDR SCNA96189S-Duct · corrodedDURING MAINTENANCE INSPECTION, CORROSION WAS FOUND IN THE INLET OF THE S-DUCT ON ENGINE 2. REMOVED CORROSION, FABRICATED AND INSTALLED A REPAIR IN ACCORDANCE WITH B727 SRM 54-10-03 FIGURE 8.SDR SCNA96146Track Light · inoperativeFLOOR EMERGENCY TRACK LIGHTING WAS FOUND INOP AT SEATS 21 DEF. REPAIRED WIRES IN TRACK, OPS CHECK OK.SDR SCNA96142Frame · damagedWHILE ACCOMPLISHING AD 94-02-04, ELONGATED HOLES WERE FOUND IN THE BS 760 AND 783 FRAMES. REPAIRED HOLES IN ACCORDANCE WITH B727 SB53-197 AND BOEING TELEX 32-9430.SDR SCNA96111Angle · corrodedDURING HEAVY MAINTENANCE VISIT, LEVEL 2 CORROSION WAS FOUND ON AFT UPPER ATTACH ANGLE AT BS 351.2 RBL 24. REMOVED CORRODED ANGLE, FABRICATED AND INSTALLED NEW ANGLE, SPLICE, AND SHIMS IN ACCORDANCE WITH B727 SRM 51-40-4 FIGURE 2.SDR SCNA96141Floor Beam · corrodedDURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON A FLOOR BOARD SUPPORT BEAM AT FS 1065, RBL 28. REMOVED CORROSION, FABRICATED AND INSTALLED A REPAIR IN ACCORDANCE WITH B727 SRM 51-40-4.SDR SCNA96035Smoke Det Batt · dischargedLEFT AFT LAV SMOKE DETECTOR WOULD NOT TEST. REMOVED AND REPLACED BATTERY IN LEFT AFT LAV SMOKE DETECTOR. DETECTOR OPS CHECKED GOOD.SDR SCNA95277Switch · dirtyTHE NUMBER ONE LEADING EDGE FLAP FAILED TO RETRACT AFTER TAKEOFF, AIRCRAFT RETURNED TO BASE. THE NUMBER ONE LEADING EDGE FLAP POSITION SWITCH AND ACTUATOR CANNON PLUG WERE CLEANED. PERFORMED ADJUSTMENT\TEST PER BOEING MAINTENANCE MANUAL AND FLAP TESTED GOOD.SDR SCNA95273Engine · failedDURING TAKEOFF ROLL, THE NUMBER TWO ENGINE EXPERIENCED A CONTAINED FAILURE AND ENGINE PARTS WERE REPORTED DEPARTING THE AIRCRAFT. THE ENGINE WAS REPLACED. THE FAILED ENGINE IS CURRENTLY UNDER EVALUATION AND SUN COUNTRY IS AWAITING THE RESULTS.SDR SCNA95253Smoke Det Batt · dischargedTHE RIGHT AFT LAV SMOKE DETECTOR WAS FOUND BEEPING CONSTANTLY. THE BATTERY VOLTAGE WAS FOUND LOW, REPLACED BATTERY AND DETECTOR TESTED GOOD.SDR SCNA95234Eel Batteries · dischargedTHE COCKPIT DOOR OVERHEAD EMERGENCY LIGHT TESTED VERY DIM. REMOVED AND REPLACED BATTERIES AND LIGHT TESTED GOOD.SDR SCNA95198Eel Wire · damagedLEFT SIDE FORWARD SECTION OF EMERGENCY TRACK LIGHTING WAS FOUND TO BE INOPERATIVE. REPAIRED SPLICE AT AFT SECTION OF FORWARD TRACK AND LIGHTING TESTED GOOD PER MM 33-50-01.SDR SCNA95177Eel Connector · looseTHE FORWARD OVERHEAD AISLE EXIT SIGN WAS FOUND INOPERATIVE, DURING FUNCTIONAL TEST. RESEATED THE CANNON PLUG ON EXIT SIGN AND THE LIGHT TESTED GOOD.SDR SCNA95176Eel Battery Pack · dischargedTHE RIGHT OVERWING EXTERIOR EMERGENCY LIGHT WAS FOUND INOPERATIVE, DURING A FUNCTIONAL TEST. CHARGED BATTERY PACK AND LIGHT TESTED GOOD.SDR SCNA95170Batteries · dischargedTHE FORWARD AND AFT LEFT LAVATORY SMOKE DETECTOR EMITTED A CHIRPING SOUND WHILE EN ROUTE. REMOVED AND REPLACED BATTERIES IN THREE LAV SMOKE DETECTORS AND OPS CHECK DETECTORS PER MM 26-00-00.SDR SCNA95157Eel Battery · dischargedFOUND THE EMERGENCY EXIT AISLE SIGN BETWEEN THE L-2 AND R-2 DOOR TO BE INOPERATIVE. REMOVED AND REPLACED BATTERY PACK M1095 AT THE AFT EMERGENCY AISLE EXIT SIGN IAW MM 33-50-22. SIGN TESTED GOOD.SDR SCNA95152Eel Battery Pack · dischargedFOUND THE EMERGENCY EXIT LIGHTING ABOVE R-2 DOOR BLINKING REMOVED AND REPLACED R-2 DOOR BATTERY PACK IAW MM 33-50-71, SYSTEM TESTED GOOD.SDR SCNA95148Eel Batteries · dischargedAFT AIRSTAIR EMERGENCY EXIT LIGHT ON VERY DIM. FOUND BATTERY PACK WITH LOW VOLTAGE AND SOME CORROSION ON TERMINALS. CLEANED TERMINALS AND INSTALLED NEW BATTERIES PER MM 33-50-61, LIGHT TESTED GOOD.SDR SCNA95128Fire Wire · faultyWHILE STARTING THE APU IN DFW THE FIRE WARNING LIGHT ILLUMINATED, BUT DID NOT RECEIVE THE WARNING BELL. THE FIRE HANDLE WAS PULLED AND ONE FIRE BOTTLE WAS DISCHARGED AND THE FIRE WARNING LIGHT EXTINGUISHED. THE APU WAS INSPECTED AND NO SIGNS OF FIRE WERE NOTSDR SCNA95122Eel Power Supply · failedLEFT AFT OVERWING EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY, EMERGENCY LIGHTS TEST GOOD.SDR SCNA95110Skin · corrodedDURING C-CHECK, FOUND 3 DISHED RIVETS AND SKIN BULGES IN THE FUSELAGE BELLY SKIN, AT BODY STATION 680 BUTT SEAM BL3R. FABRICATED DOUBLERS AND FILLERS, INSTALLED IAW SRM 53-30-03 AND 51-30-02.SDR SCNA95062Retract Mech · malfunctionedLANDING GEAR REQUIRED ONE RECYCLE TO GET NOSE GEAR TO COME DOWN. FIRST ATTEMPT MAIN LANDING GEAR INDICATED DOWN AND LOCKED, BUT NOSE DOORS AND GEAR REMAINED IN UP POSITION. PERFORMED NOSE GEAR SWING IAW 7-11-00, OPS CHECKED OK.SDR SCNA95029Eel Battery Pack · dischargedFORWARD AISLE EMERGENCY EXIT SIGN IS INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AT FORWARD AISLE EXIT SIGN. OPERATIONS CHECK GOOD.SDR SCNA95028Overheat Line · brokenAFTER SHUT DOWN OF APU HAD FIRE INDICATION OF RED LIGHT IN FIRE SWITCH WITH EGT OF 550 DEGREES. PULLED FIRE SWITCH AND DISCHARGED BOTTLE. FIRE INDICATIONS WENT OUT AFTER THAT. VISUALLY INSPECTED APU AND NO EVIDENCE OF FIRE FOUND. REMOVED AND REPLACED APU FSDR SCNA95013Smoke Det · dischargedMSP - AFT LAVATORY SMOKE DETECTOR INOPERATIVE. INSTALLED NEW BATTERY AND TESTED GOOD. (W)SDR SCNA95012Valve · leaksMSP - ACFT RETURNED TO GATE, CREW REPORTED SMOKE IN CABIN AND COCKPIT. FOUND THE PARKING BRAKE VALVE LEAKING SKYDROL INTO APU INTAKE. REPLACED VALVE AND OPERATIONS CHECKED NORMAL. (W)
Back to N288SC, cancelled Aug 5, 2008