N289SC, cancelled Dec 12, 2002
Service difficulty reports · 162
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N289SC' AND deregistration_id = 'N289SC-2002-12-12' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N289SC' AND deregistration_id = 'N289SC-2002-12-12' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA96386Wire · brokenTHE CEILING MOUNTED EMERGENCY EXIT SIGN AT THE L-2 DOOR WAS FOUND TO BE INOPERATIVE. FOUND BROKEN WIRE AT CONNECTOR TO SIGN. REPINNED CONNECTOR AND LIGHT TESTED GOOD IAW MM 33-50-91.SDR SCNA96376Power Supply · inoperativeFOUND RIGHT OVERWING EMERGENCY LIGHT INOP. REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY PER MM 33-50-71 AND OPS CHECKED GOOD.SDR SCNA96348Lamp · failedFOUND RIGHT HAND FORWARD EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP AND OPS CHECKED GOOD.SDR SCNA96313Smoke Detector · inoperativeFORWARD LAV SMOKE DETECTOR DID NOT TEST. REMOVED AND REPLACED SMOKE DETECTOR AND OPS CHECKED NORMAL.SDR SCNA96287Power Supply · inoperativeFOUND R2 DOOR OVERHEAD EMERGENCY EXIT SIGN DIM. REMOVED AND REPLACED BATTERY PACK AND POWER SUPPLY IN ACCORDANCE WITH MM 33-50-91, SYSTEM OPS CHECKED GOOD.SDR SCNA96286Wire · brokenFOUND AISLE EMERGENCY LIGHT UNSECURED AND WIRES SEVERED BETWEEN AFT SERVICE DOORS. REPAIRED EMERGENCY EXIT WIRES, RESECURED FIXTURE AND OPS CHECKED GOOD.SDR SCNA96144Fire Loop · malfunctionedTHE NUMBER 3 ENGINE FIRE WARNING LIGHT ILLUMINATED AND HORN SOUNDED. SHUT DOWN NUMBER 3 ENGINE. REMOVED AND REPLACED NUMBER 3 ENGINE FIRE LOOP, OPS CHECKED OK.SDR SCNA96020Ribbon Lead · chafedTHE EMERGENCY TRACK LIGHTING FROM SEAT 7 ABC TO 14 ABC FLICKERS ON AND OFF. FOUND CHAFED RIBBON SUPPLY LINE FROM BATTERY. REPLACED CHAFED RIBBON LEAD AND OPS CHECKED EMERGENCY LIGHTS IAW MM 33-50-00.SDR SCNA96018Connector · corrodedSECOND SECTION OF EMERGENCY PATH LIGHTING FROM THE FRONT WAS FOUND TO BE INTERMITTENT. CLEANED CORROSION FROM CANNON PLUG AT THE POWER SUPPLY AND LIGHTING TESTED GOOD.SDR SCNA96014Battery Pack · dischargedTHE EXTERIOR EMERGENCY EXIT LIGHT ON THE AFT RIGHT CARGO DOOR TESTED DIMLY. REMOVED AND REPLACED BATTERY PACK AND LIGHT TESTED GOOD.SDR SCNA96009Switch · corrodedAFTER GEAR RETRACTION NOSE GEAR INDICATION WAS RED AND GREEN AT THE SAME TIME. FOUND THE LANDING GEAR POSITION SWITCH (S93) CORRODED AND HANGING UP. REMOVED AND REPLACED SWITCH AND CANNON PLUG (D300). INDICATION CHECKED GOOD PER B727, MM 32-61-71.SDR SCNA96008Switch · lack of lubeAFTER GEAR RETRACTION, NOSE GEAR INDICATION WAS RED AND GREEN AT THE SAME TIME. JACKED NOSE OF THE AIRCRAFT, SWUNG GEAR, LUBED AND CLEANED THE DOWNLOCK SWITCH. INDICATION CHECKED NORMAL.SDR SCNA96007Switch · failedAFTER GEAR RETRACTION, NOSE GEAR INDICATION WAS RED AND GREEN AT THE SAME TIME. REPLACED THE NOSE GEAR LOCK SWITCH PER MM 32-61-01 PAGE 404. PERFORMED NOSE GEAR LOCK AND POSITION SWITCH ADJUSTMENT AND TEST PER MM 32-61-71 PAGE 501.SDR SCNA95299Accessory Unit · failedMCO - ON DEPARTURE AFTER GEAR RETRACTION, NOSE GEAR RED AND GREEN LIGHT REMAINED ON. RECYCLED GEAR WITH SAME RESULT. INSPECTED NOSE GEAR THROUGH VIEWER AND VISUALLY CONFIRMED NOSE GEAR UP AND DOORS CLOSED. CHECKED NOSE GEAR UPLOCK SWITCH, DOWN LOCK SWITCH ASDR SCNA95294Batteries · dischargedTHE OVERHEAD L-1 DOOR PORTABLE EMERGENCY EXIT LIGHT ILLUMINATES MOMENTARILY THEN GOES OUT. REMOVED AND REPLACED BATTERIES IAW MM 33-50-101, LIGHT OPS CHECKED GOOD.SDR SCNA95286Eel Track · failedTHE EMERGENCY FLOOR TRACK LIGHTING WAS FOUND INOPERATIVE IN THE AFT CABIN. REMOVED AND REPLACED SHORTED LUMINESCENT FLOOR TRACK LIGHTING STRIP, OPS CHECKED NORMAL.SDR SCNA95272Eel Lamp · failedTHE R-1 DOOR SLIDE EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. RELAMPED LIGHT AND UNIT TESTED GOOD.SDR SCNA95264Accessory Unit · failedDURING CLIMB AFTER GEAR RETRACTION, RED AND GREEN NOSE GEAR LIGHTS ILLUMINATED. ALL INDICATIONS WERE NORMAL DURING RETRACTION AND EXTENSION. REMOVED AND REPLACED LANDING GEAR ACCESSORY UNIT PER MM 32-09-12, OPS CHECKED GOOD PER MM 32-09-121.SDR SCNA95259Eel Sign · inoperativeTHE EMERGENCY EXIT SIGN AT THE L1 DOOR WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED EXIT SIGN AT THE L1 DOOR, LIGHT TESTED GOOD.SDR SCNA95255Harness · chafedNOSE GEAR INDICATION PROBLEM WAS NOTED DURING GEAR RETRACTION, AIRCRAFT RETURNED TO STATION. WHEN THE GEAR WAS LOWERED ALL INDICATIONS WERE NORMAL. DURING POST FLIGHT INSPECTION THE LOWER LINK ATTACH BOLT (NAS-104-47W), WAS FOUND CRACKED. THE BOLT WAS REPLASDR SCNA95248Eel Assy · failedTHE COCKPIT PORTABLE EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. REMOVED AND REPLACED LIGHT ASSEMBLY AND LIGHT TESTED GOOD.SDR SCNA95247Battery · dischargedTHE FORWARD CEILING MOUNTED EMERGENCY AREA LIGHT WAS FOUND INOPERATIVE. REPLACED BATTERIES IAW 33-50-81 AND LIGHT TESTED GOOD.SDR SCNA95240Eel Assy · inoperativeTHE AFT ENTRY EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED AFT ENTRY EMERGENCY EXIT LIGHT ASSEMBLY PER MM 33-50-101 AND LIGHT TESTED GOOD.SDR SCNA95238Eel Battery Pack · dischargedTHE AFT THIRD OF EMERGENCY TRACK LIGHT WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED THE POWER SUPPLY AND REPLACED 2 STRIPS OF FLOOR LIGHTS.SDR SCNA95233Eel Bulb · failedTHE L-1 DOOR EXTERIOR EMERGENCY SLIDE LIGHT WAS FOUND TO BE INOPERATIVE. RELAMPED THE L-1 DOOR EMERGENCY SLIDE LIGHT AND LIGHT TESTED GOOD.SDR SCNA95232Eel Battery Pack · dischargedTHE AFT OVERHEAD EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED BATTERY PACK AND CLEANED CORROSION ON BATTERY CONTACTS AND LIGHT TESTED GOOD.SDR SCNA95231Eel · failedTHE FORWARD RIGHT OVERWING EXIT DOOR EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. RESEATED CANNON PLUG ON LIGHT ASSEMBLY AND LIGHT TESTED GOOD.SDR SCNA95230Eel · failedTHE AFT RIGHT OVERWING EXIT DOOR EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. RESEATED CANNON PLUG ON LIGHT ASSEMBLY AND LIGHT TESTED GOOD.SDR SCNA95229Eel · failedTHE FORWARD LEFT OVERWING EXIT DOOR EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. REMOVED AND REPLACED EXIT LIGHT ASSEMBLY AND LIGHT TESTED GOOD.SDR SCNA95220Web · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), THE WEB AT BS 950B, LBL 10 WAS FOUND TO HAVE LEVEL 1 CORROSION. REMOVED CORROSION, FABRICATED AND INSTALLED DOUBLER AND FILLER REPAIRS IAW B727 SRM 51-40-03 AND SRM 53-10-01.SDR SCNA95227Blkhd Chord · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), BS 950 BULKHEAD LOWER T-CHORD HAS LEVEL 2 INTERGRANULAR CORROSION AT STRINGER 29R. REMOVED AND REPLACED THE LOWER CHORD IAW B727 SRM 51-40-04 AND SRM 51-10-06.SDR SCNA95226Support · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), LEVEL 2 CORROSION WAS FOUND ON THE CABIN FLOOR SUPPORT AT BS 380 STRINGER 17R-RBL 64. REMOVED CORRODED SECTION OF BEAM, FABRICATED, AND INSTALLED REPAIR MEMBERS IAW B727 SRM 53-10-08.SDR SCNA95221Support · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), THE CABIN FLOOR SUPPORT AT BS 360-380, RBL 12 (NEAR STRINGER 17R) WAS FOUND TO HAVE LEVEL 1 CORROSION. REMOVED CORRODED FLOOR SUPPORT, FABRICATED AND INSTALLED NEW FLOOR SUPPORT IAW B727 SRM 53-10-08.SDR SCNA95219Support · crackedDURING HEAVY MAINTENANCE VISIT (HMV), A CRACK AND LEVEL 1 CORROSION WAS FOUND ON THE FLOOR SUPPORT AT BS 284.5, RBL 0 TO RBL 6. REMOVED CRACK AND CORROSION, FABRICATED L-ANGLE REPAIR AND FILLER AND INSTALLED IAW B727 SRM 51-40-04 AND SRM 53-10-08.SDR SCNA95225Floor Beam · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), LEVEL 2 CORROSION WAS FOUND ON THE MAIN CABIN FLOOR BEAM AT BS 400 STRINGER 17-LBL 24 THRU RBL 12. REMOVED AND REPLACED THE FLOOR BEAM IAW B727 SRM 53-10-08.SDR SCNA95224Floor Beam · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), LEVEL 2 CORROSION WAS FOUND ON THE MAIN CABIN FLOOR BEAM UNDER TAPE AND CLIP NUTS AT BS 344, RBL 14 TO THE L-1 DOOR. REMOVED CORRODED SECTION OF BEAM, FABRICATED AND INSTALLED REPAIR MEMBERS IAW B727 SRM 53-10-08.SDR SCNA95223Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), THE SEAT TRACK LOCATED AT BS 344-460, ON THE INBOARD SIDE OF STRINGER 17L, WAS FOUND TO HAVE LEVEL 2 CORROSION. REMOVED AND REPLACED THE SEAT TRACK IAW B727 SRM 53-10-05.SDR SCNA95217Door Jamb · crackedDURING HEAVY MAINTENANCE VISIT (HMV), A CRACK WAS FOUND IN THE R1 DOOR JAMB LOWER FORWARD CORNER. THE DOOR JAMB WAS REMOVED, CRACK STOP DRILLED, REPAIRS FABRICATED AND INSTALLED IAW B727 SRM 51-40-03.SDR SCNA95216Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), THE OUTBOARD SEAT TRACK AT BS 360-440, NEAR STRINGER 17, WAS FOUND TO HAVE LEVEL 2 CORROSION. REMOVED AND REPLACED SEAT TRACK IAW B727 SRM 53-10-05.SDR SCNA95213Floor Beam · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), THE CABIN FLOOR BEAM AT BS 440 RBL 4 TO RBL 12 WAS FOUND TO HAVE LEVEL 2 CORROSION. REMOVED AND REPLACED THE FLOOR BEAM IAW B727 SRM 53-10-08.SDR SCNA95212Support · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), THE CABIN FLOOR SUPPORT AT BS 344-360, RBL 12 WAS FOUND TO HAVE LEVEL 1 CORROSION. REMOVED CORRODED SECTION, FABRICATED AND INSTALLED NEW REPAIR MEMBERS IAW B727 SRM 53-10-08.SDR SCNA95211Support · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), THE FLOOR SUPPORT AT BS 380-400 RBL-WL 208 WAS FOUND TO HAVE LEVEL 1 CORROSION. REMOVED CORRODED FLOOR SUPPORT, FABRICATED AND INSTALLED NEW REPAIR MEMBERS IAW B727 SRM 53-10-08.SDR SCNA95228Support · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), LEFT LOWER SUPPORT FRAME AT BS 750E TO 740 FOR BODY FAIRINGS WAS FOUND TO HAVE LEVEL 2 CORROSION BEYOND SRM LIMITS. REMOVED AND REPLACED SUPPORT FRAME IAW B727 51-40-03.SDR SCNA95222Floor Beam · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), THE FLOOR BEAM AT BS 1110 WAS FOUND TO HAVE LEVEL 2 CORROSION. REMOVED CORRODED UPPER CHORD, FABRICATED AND INSTALLED NEW UPPER CHORD, ANGLES, AND ANGLE STRAPS IAW B727 SRM 53-10-08.SDR SCNA95215Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), THE CENTER FLOOR MOUNT RAIL AFT OF BS 640, INBOARD OF STRINGER 28L, WAS FOUND TO HAVE LEVEL 2 CORROSION. REMOVED CORRODED SECTION OF SEAT TRACK, FABRICATED AND INSTALLED REPAIRS IAW B727 SRM 53-40-03.SDR SCNA95214Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), THE CENTER FLOOR MOUNT RAIL AFT OF BS 640, NEAR STRINGER 27R, WAS FOUND TO HAVE LEVEL 2 CORROSION. REMOVED CORRODED SECTION OF SEAT TRACK, FABRICATED AND INSTALLED REPAIRS IAW B727 51-40-03.SDR SCNA95218Stringer · corrodedDURING HEAVY MAINTENANCE VISIT (HMV), STRINGER 27R WAS FOUND TO HAVE LEVEL 2 CORROSION BETWEEN STATION 720C THROUGH 720D. REMOVED CORRODED SECTION OF STRINGER, FABRICATED AND INSTALLED REPAIR MEMBERS IAW B727, SRM 53-10-01 AND SRM 51-40-04.SDR SCNA95167Eel Battery Pack · dischargedTHE FORWARD MIDDLE EMERGENCY PATH LIGHTING INOPERATIVE. REMOVED AND REPLACED THE BATTERY PACK AND LIGHTING TESTED GOOD PER MM 33-50-01.SDR SCNA95144Eel · inoperativeFOUND THE L1 DOOR EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED PORTABLE EMERGENCY SIGN OVER L1 DOOR, OPS TESTED GOOD PER B727 MM 33-50-101.SDR SCNA95143Eel Wire · damagedFOUND THE AFT FLOOR TRACK LIGHTS INOPERATIVE. WIRES WERE FOUND DAMAGED; REPAIRED WIRES AND FLOOR TRACK LIGHTING SYSTEM TESTED GOOD.
Back to N289SC, cancelled Dec 12, 2002