N302UA, cancelled Mar 18, 2013
Service difficulty reports · 42
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N302UA' AND deregistration_id = 'N302UA-2013-03-18' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N302UA' AND deregistration_id = 'N302UA-2013-03-18' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA05490Wedge · damagedLT NR 3 SLAT WEDGE HAS DAMAGE. REMOVED NR 3 SLAT, R&R R425 60 TO SHOP AND RE-INSTALLED. INSPECTED INSTALLATION, FOUND OKAY.
SDR 2008UALA04345Control Panel · inoperativeCREW REPORT: CARGO FIRE DETECTION SYSTEM INOP. SUPPLEMENTAL DATA UPDATE FOUND FIRE CONTROL PANEL TO BE FAULTY. REPLACED CARGO FIRE CONTROL PANEL PER MM 26-00-02. OPS TEST NORMAL. AC OK FOR SERVICE.SDR 2008UALA04100Switch · inoperativeDURING FIRE TEST, THE F/O'S MASTER FIRE WARNING LIGHT WILL NOT ILLUMINATE. FOUND FAULTY SWITCH. REPLACED F-O MASTER WARNING SWITCH. OPS CHECKED OK. ACFT OK FOR SERVICE.SDR 2008UALA02574Girt Bar · out of toleranceDOOR 1R GIRT BAR BROKE. FOUND GIRT BAR STOWAGE BRACKET FASTENERS LOOSE. SECURED BRACKET. BAR STOWS OK. AC OK FOR SERVICE.SDR 2008UALA01458Test Unit · inoperativeFIRE TEST INOPERATIVE. REPLACED MODULE ASSEMBLY FIRE TEST OK. AC OK FOR SERVICE.SDR 2008UALA01376Warning System · activatedFIVE MILE FINAL UNSAFE GEAR INDICATION RED UNSAFE GEAR LIGHTS ILLUMINATED DURING GO-AROUND ACHIEVED. NO FAULT FOUND. LUBED GEAR HANDLE SLIDE MECHANISM.
SDR UALA2008111301002Outflow Valve · frozenFLIGHT DIVERTED WITH A PRESSURIZATION PROBLEM. OUTFLOW VALVE FREEZING UP. REPLACED OUTFLOW VALVE AND HEAT GASKET. AWAITING SHOP FINDINGS.SDR 2008UALA01002Cabin Pressure · unknownFLIGHT DIVERTED WITH A PRESSURIZATION PROBLEM.SDR 2008UALA00742Stop · crackedFWD CARGO DR CUTOUT, FWD FRAME AT LWR STOP PAD FITTING CRACKED ON FWD SIDE OF FRAME IN UPPER RADIUS. MAJOR REPAIR: ACCOMPLISHED REPAIR.SDR 2008UALA00743Wedge · delaminatedDURING RIGGING OF LEFT WING INBOARD SPOILER FOUND MID FLAP TRAILING EDGE LOWER SKIN DELAMINATED AND SEPARATED FROM MIDFLAP. ACCOMPLISHED REPAIR OF DELAMINATED SKIN.SDR 2008UALA00526Skin · delaminatedLEFT INBOARD MID FLAP DELAMINATED OUT OF LIMITS. REPAIRED DELAMINATION.SDR 2007UALA05301Unknown · unknownCREW REPORT: LOST CABIN PSI AT 10000 DURING DESCENT. WARNING HORN WENT OFF. LANDED NORMAL.SDR 2007UALA04614Feeder Cable · faultyAFT CABIN EEL LIGHTS INOP. REPLACED POWER CABLE JUMPER.SDR 2007UALA03917Battery Pack · dischargedMID CABIN EMERGENCY LIGHTS INOP FROM SEAT ROW 11ABC TO 16ABC. REPLACED BATTERY PACK AND CHARGER.SDR 2007UALA03916Light · inoperativeFIRST CLASS CABIN EMERGENCY LIGHTS INOPERATIVE. RELAMPED EMERGENCY LIGHTS.SDR 2007UALA03375Csd · overservicedCREW REPORT: AFTER LANDING NR 2 HI OIL TEMP CSD LIGHT CAME ON. ENG SHUT DOWN AND LIGHT WENT OUT AFTER 5 MINUTES. FOUND OVERSERVICE OF CSD. DRAINED CSD OIL AND RESERVICED TO PROPER LEVEL. PERFORMED ENGINE RUNS WITH DEFECTS OR ABNORMALITIES NOTED.SDR 2007UALA02530Smoke Warning · intermittentSMOKE ALARM ON INTERMITTANTLY AFT LAVATORY. [07-27-07] ALL OPERATIONAL CHECKS WERE NORMAL.SDR 2007UALA02182Warning Light · illuminatedRTFL DUE TO FUEL FILTER BYPASS LIGHT ON NR 2 ENGINE. 10-11-07 FOUND BAD FUEL FILTER DIFFERENTIAL SWITCH. REPLACED SWITCH.SDR 2007UALA01296Power Supply · dischargedRT OVERWING SIDEWALL EMERGENCY LIGHT OUT. BAD INVERTER, SWAPPED WITH LT TO CONFIRM. REPLACED POWER SUPPLY.SDR 2007UALA00802Controller · malfunctionedENG 2 THROTTLE STUCK. ENG 2 N1 WILL NOT GO BELOW 75 PERCENT N1 AND 3000 FF WITH THRUST LEVER AT IDLE. [SUP 05-29-07] FAULTY MAIN ENGINE CONTROLLER. REPLACED THE MAIN ENGINE CONTROLLER. UNIT FAILED BENCH TEST. FOUND FAILED CDP. UNIT REQUIRES OVERAHAUL.SDR 2007UALA00195Oxygen System · lowCREW OXYGEN SYSTEM LOW. FOUND O2 PRESSURE AT 1K PSI. SERVICE OXYGEN SYSTEM TO FULL. [SUP 4-17-07] CAUSE UNKNOWN, SERVICED OXYGEN SYSTEM TO FULL.SDR 2006UALA01689Skin · ground damageAIRCRAFT STRUCK BY JETWAY. REMOVED DAMAGE. FABRICATED AND INSTALLED DOUBLER AND TRIPLER REPAIR.SDR 2006UALA01699Stringer · crackedSTRINGER 16L AT APPROXIMATELY STA 384-388 HAS LONGITUDINAL CRACK IN LOWER RADIUS. REPAIRED STRINGER AND MANUFACTURED NEW FRAME CLIPSDR 2006UALA01368Adc · malfunctionedREJECTED TAKEOFF AT 100 KTS DUE TO AIRSPEED INDICATOR. REPLACED NR 1 ADC. ADC REQUIRES CALIBRATION. NOT RECIEVING ARINC SIGNAL. FOUND IC U33 OF BOARD A6 FAULTY. REPLACED NR 1 ADC. FOR THE FAULTY ADC: CALIBRATED. REPLACED U33 ON A6 BOARD.SDR 2006UALA00922Light · inoperativeAFT SECTION OF EEL STRIP DOES NOT LIGHT.SDR 2006UALA00473Skin · damagedDAMAGE TO AREA BELOW FWD LAV SERVICE POINT. REMOVED FASTENERS AND PREPARED AREA FOR SHEET METAL REPAIR. MANUFACTURED FILLER, DOUBLER AND TRIPLER AND LOCATED HOLES REF SRM 53-10-01 REPAIR 11. PRIMERED, SEALED & STARTED INSTALLATION, REF SRM 53-10-01 (DETAILSDR 2005UALA00114Skin · dentedRT HORIZ LEADING EDGE DENT APPROX 7 FT FROM INBOARD EDGE. DENT IS APPROX 5 INCHES IN LENGTH, 1.5 INCH WIDE AND .125 IN DEPTH. REPAIR ACCOMPLISHED. INTERIM DOUBLER REPAIR REPLACED WITH PERMANENT FLUSH REPAIR.SDR 2005UALA00107Skin · dentedVERTICAL STAB LEADING EDGE IS DENTED AT L/E STA 104. REMOVED DENT DAMAGE AND INSTALLED DOUBLER REPAIR.SDR 2005UALA00106Floorbeam · corrodedCABIN FLOORBEAM HAS CORROSION REMOVAL BEYOND LIMITS AT STA 967 LBL 18. INSTALLED STRAP REPAIR.SDR 2005UALA00076Pressure Panel · crackedSTA 664 PRESSURE DECK HAS 2 CRACKS AT LBL 30. CUT-OUT WEB AND INSTALLED SPLICE REPAIR.SDR 2005UALA00056Floorbeam · corrodedSTA 947 FLOORBEAM HAS MATERIAL LOSS FROM CORROSION AT LBL 4. REMOVED CORROSION INTALLED REPAIR STRAP.SDR 2005UALA00055Frame · crackedSTA 616 FRAME INNER CHORD IS CRACKED FROM BOTTOM FASTENER BELOW STR 17 LT. CUT-OUT DAMAGE AND INSTALLED ANGLE DOUBLER.SDR 2004UALA00187Light · shortedAFT GALLEY EEL LIGHT IS SHORTING OUT THE AFT SECTION OF THE EEL SYSTEM. REPLACED LIGHT STRIP.SDR 2004UALA00186Light · inoperativeRIGHT AFT OVERWING SLIDE LIGHT IS INOPERATIVE. RELAMPED SLIDE LIGHT.SDR 2002UALA01070Csd · damagedAFTER TAKEOFF, ONE GENERATOR BECAME INOPERATIVE. RETURNED TO FIELD WHEN UNABLE TO START APU. METAL PARTICLES FOUND IN MAG PLUG BOSS. BOSS WAS BROKEN WITH TWO PIECES OF BRASS. ONE WEDGED IN CHECK VALVE OF BOSS. REPLACED CSD, OIL COOLER, AND CHANGED NR 1 GESDR 2002UALA00888Door · departedDURING FLIGHT WING OUTBOARD FUEL BOOST PUMP DOOR DEPARTED AIRCRAFT. REPLACED DOOR.SDR 2001UALA02393Oven · fireCREW REPORTS FORWARD GALLEY OVEN HAD A SMALL DEBRIS FIRE (PAPER). USED HALON BOTTLE TO EXTINGUISH. REMOVED AND REPLACED FORWARD OVEN, CHECKS OK.SDR 99UAL900306Controller · failedTHE RIGHT PRESSURIZATION PACK CIRCUIT BREAKER TRIPPED. *S/D* FAILURE OF THE RIGHT PACK RAM AIR CONTROLLER AND SENSOR. REPLACED BOTH THE RAM AIR TEMPERATURE SENSOR AND RAM AIR CONTROLLER.SDR 99UAL900295Pack · failedTHE RIGHT SIDE PRESSURIZATION PACK TRIPPED OFF AND THE AIRCRAFT CABIN ALTITUDE RAPIDLY INCREASED. *S/D* FOUND RIGHT PACK TURBOFAN MAKING LOUD NOISE. REPLACED RIGHT PACK TURBOFAN. REF MRR 99UAL900306 FOR SUBSEQUENT MAINTENANCE ACTIONS.SDR 99UAL900285Control Panel · malfunctionedUNABLE TO MAINTAIN PRESSURIZATION. *S/D* LEFT AIR CONDITIONING PACK TRIPPED OFF FOLLOWED BY THE RIGHT PACK TRIPPED OFF AND WOULD NOT RESET. ADJUSTED LEFT RAM AIR EXHAUST LOUVERS. REPLACED AIR CONDITIONING ACCESSORY UNIT, OVERHEAD CONTROL PANEL AND CABIN TESDR 98UAL900169Overheat Light · illuminatedLEFT WING BODY OVERHEAT LIGHT WAS ILLUMINATED AND REMAINED ON AFTER THE DUCT WAS DEPRESSURIZED.SDR 95UAL737026Eel Battery · dischargedEMERGENCY ESCAPE PATH LIGHTING INOP AT ROWS 11,13,17,18 AND EMERGENCY EXIT LIGHT AT DOOR TWO LEFT. REPLACED BATTERY PACK AND CHARGER ASSEMBLY.
Back to N302UA, cancelled Mar 18, 2013