N317UA, cancelled Nov 30, 2005
Service difficulty reports · 22
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N317UA' AND deregistration_id = 'N317UA-2005-11-30' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N317UA' AND deregistration_id = 'N317UA-2005-11-30' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2002UALA01479Transmitter · failedAIRCRAFT LANDED UNDER AMBER ALERT DUE TO SPLIT FLAP INDICATION. NR 2 FLAP TRANSMITTER INOP. REPLACED TRANSMITTER WITH A SERVICEABLE UNIT.SDR 2001UALA00986Floorbeam · corrodedFLOORBEAM CORRODED STA 947.5, RBL 30. *S/D* MAJOR REPAIR ACCOMPLISHED. INSTALLED STRAP REPAIR.SDR 2001UALA00980Floorbeam · corrodedTOP OF FLOORBEAM HAS CORROSION. BLENDED MATERIAL LOSS OUT OF LIMITS, AT BS 1016. REMOVED CORROSION. INSTALLED REPAIR STRAP AND NEW INTERCOSTAL. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00976Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 663, STR 10L. REPLACED STRINGER CLIP. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00975Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 706, STR 2L. REPLACED CLIP. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00974Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 706, STR 3L. REPLACED STRINGER CLIP. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00973Door Frame · crackedFWD GALLEY DOOR AFT CUTOUT FRAME CRACKED. INSTALLED REPAIR ANGLE DOUBLER. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00891Frame · dentedAFT PIT FRAME DENTED AT BS 767, ABOVE STR 24L. ACCOMPLISHED FRAME DOUBLER REPAIR. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00865Floorbeam · damagedEXCESSIVE MATERIAL LOSS ON CABIN FLOORBEAM AT BS 947.5, LBL 15. ACCOMPLISHED REINFORCING ANGLE REPAIR. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00861Frame · dentedFWD CABIN FRAME AT BS 400, NEAR STR 16R IS DENTED. ACCOMPLISHED STRAP REPAIR. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00815Frame · damagedFRAME WEB HAS EXCESSIVE MATERIAL LOSS AT BS 500, BL 0, WL 151. ACCOMPLISHED DOUBLER REPAIR. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00814Frame · dentedAFT PIT FRAME DENTED AT BS 767, ABOVE STR 24L. REPAIRED WITH FRAME DOUBLER. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00809Crease Beam · corrodedUPPER SURFACE OF LT CREASE BEAM WEB CORRODED AT BS 696, LBL 65. REPLACED CREASE BEAM WEB. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00808Intercostal · crackedFLOOR SUPPORT INTERCOSTAL CRACKED THRU UPPER CHORD FASTENER HOLE AT BS 360, BL 0. REPLACED INTERCOSTAL. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00807Floorbeam · corrodedCABIN FLOORBEAM CORRODED AROUND NUT PLATE HOLE AT BS 294, RBL 21. INSTALLED STRAP DOUBLER. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00769Bulkhead · crackedWEB CRACKED AT BS 178, BL 0, WL 188. INSTALLED WEB DOUBLER. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00191Bolt · improper partFUEL SEEPING FROM THE TOP OF THE RIGHT WING. *S/D* FOUND THE FUEL LEAK TO BE RESULTING FROM BOLTS BOTTOMING OUT IN THE DOME NUTS IN THE SUSPECTED PANEL. REPLACED THE PANEL. THE BOLTS HAVE BEEN SWITCHED OUT WITH SHORTER ONES IN ORDER TO ELIMINATE THE PROBLESDR 2000UALA00694Pressure Switch · malfunctionedFUEL BOOST PUMP LIGHTS FLICKERED. SUPPLEMENTAL DATA UPDATE REMOVED AND REPLACED NR 2 AFT LOW PRESSURE SWITCH.SDR 98UAL900337Sensor · failedRIGHT EQUIPMENT COOLING SUPPLY EXHAUST OFF LIGHT ILLUMINATED DURING CLIMB, LEVEL OFF, AND THE FIRST PART OF DESCENT. SELECTING ALTERNATE DID NOT WORK-IN NORMAL. ON THE GROUND THE LIGHT EXTINGUISHES. COULD ONLY DUPLICATE IN FLIGHT. *S/D* PROBLEM WAS CAUSEDSDR 97UAL900473Tire · failedTIRE BLEW ON TAKEOFF. *S/D* NO SPECIFIC CAUSE NOTED REGARDING TREAD SEPARATION. REPLACED NR 1 AND NR 2 MAIN TIRES, OPS CHECK GOOD.SDR 97UAL900207Tire · failedTIRE BLEW ON TAKEOFF. NO SPECIFIC CAUSE NOTED REGARDING TREAD SEPARATION. REPLACED NR 1 AND NR 2 MAIN TIRES. OPS CHECK GOOD.SDR 96UAL900407Switch · failedGALLEY OVEN SMOKING, SPARKING WHEN ON. SMOKE COMING FROM HEATER ON LIGHT. *S/D* FOUND SHORT CIRCUIT IN HEATER ON SWITCH. PROBABLY CAUSED BY MOISTURE IN SWITCH. REPLACED SWITCH, CLEANED OVEN AND CHECKS OK.
Back to N317UA, cancelled Nov 30, 2005