N327UA, cancelled Aug 10, 2012
Service difficulty reports · 50
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N327UA' AND deregistration_id = 'N327UA-2012-08-10' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N327UA' AND deregistration_id = 'N327UA-2012-08-10' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009072102154Light · inoperativeFLOOR EMERGENCY EXIT LIGHTING INOP FROM SEAT ROW 15-21 AND GALLEY STRIP AFT OF ROW 21. REPLACED LIGHT SEGMENTS.SDR UALA2009072002129Battery · malfunctionedELECTRICAL SYSTEM ISSUE, FLIGHT DIVERTED. BOTH IRS DC FAIL LIGHTS ILLUMINATED. BATTERY VOLTAGE SLOWLY DROPPED TO 14 VOLTS. REPLACED BATTERY, BATTERY CHARGER AND RELAY R41.SDR UALA2009072002120Light · inoperativeFLOOR EEL LIGHTS FROM ROW 15 AFT INOP. CLEANED CONNECTIONS AT LIGHT STRIP IN AFT GALLEY, OPS CHECKS NORMAL NOW.SDR UALA2009051301353Insulator · brokenNR 1 ENGINE CORE OVHT-FIRE DETECTOR LOOP HAS A BROKEN CERAMIC INSULATOR. INBD SIDE (M1122) REPLACED DETECTOR. FIRE TEST PASSED ON GROUND.SDR UALA2009033000920Light · inoperativeOVERWING EMERGENCY LIGHT LT INOP. RELAMPED EMERGENCY LIGHT. OP CHECK NORMAL.SDR UALA2009020200352Pin · brokenAFT END OF EEL STRIP IS BROKEN. REPLACED AFT MOST EEL STRIP BY AFT GALLEY CARTS. FOUND BROKEN PINS ON CONNECTOR. CHECKS GOOD.SDR UALA2008111706525Light · looseEMERGENCY FLOOR LIGHTS LOOSE NEAR ROW 6 ABC. SECURED EMERGENCY LIGHTS.SDR 2008UALA06213Skin · delaminatedRT OUTBOARD TRAILING EDGE FLAP OUTBOARD LOWER SURFACE DELAMINATED APPROX 72 SQ INCHES. REPLACED DAMAGED OUTBOARD AFT FLAP ON RT WING. OP CHECKED GOOD. ACFT OK FOR SERVICE.
SDR 2008UALA04266Structure · dentedFUSELAGE ON LEFT SIDE FWD OF ENGINE IS DENTED.SDR 2008UALA04108Light · inoperativeEEL LIGHTS ARE INOP FROM ROW 16 AFT. *S/D* REMOVED & REPLACED EEL LIGHTS FROM ROW 16 AFT. OPS CHECK NORMAL.SDR 2008UALA02587Light · faultyEEL LIGHTS FROM ROW 15 ON BACK DO NOT ILLUMINATE. REPLACED LIGHT ASSEMBLY OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA00187Light · inoperativeAFT SECTION OF EEL LIGHTS INOP. CLEANED AND REPLACED SHORTED POWER STRIP.SDR 2007UALA03703Controller · failedCABIN PRESSURE NOT CONTROLLED ON DESCENT IN STANDBY MODE. AT 5.0 PRESSURE BUMP & CABIN CLIMBED TO MATCH ACFT ALT. NO TIME TO SELECT MANUAL. FOUND CABIN PRESSURE CONTROLLER FAILED. REPLACED CABIN PRESSURE CONTROLLER. ALL TESTS PERFORMED NORMALLY- NO REPEATSSDR 2007UALA03255Door Frame · gougedAFT CARGO DOOR OPENING, FWD FRAME HAS DEEP GOUGE AT LOWER END, MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED FRAME.SDR 2007UALA03215Threshold · corrodedAFT PIT DOOR THRESHOLD CORRODED: WEB IS CORRODED AT STA 819 RLB 21 APPROX 2 IN FROM UPPER FLANGE. MAJOR REPAIR ACP AFT CARGO PIT DOOR THRESHOLD WEB.
SDR 2007UALA03214Crease Beam · damagedAFT PIT OPENING, NEED TO CUT RT CREASE BEAM INNER CHORD AT CABIN FLOOR STR 17R TO REMOVE SEGMENT TO FACILITATE FRAME REPAIR AT BS 781. REPAIRED PER SRM 51-70-12 FIG 1 SHEET 3 PAGE 5-6.SDR 2007UALA03213Door Frame · crackedFWD CARGO DOOR OPENING, AFT FRAME IS CRACKED AT LOWER STOP FITTING. REPAIRED FWD CARGO DOOR AFT FRAME PER MM 53-30-75 PG 801-815.SDR 2007UALA00777Connector · faultyLAST 20 INCHES OF EEL LIGHTING IN AFT MAIN CABIN IS INOP. CLEANED MOISTURE FROM AFT CONNECTION BETWEEN GALLEY EEL STRIP AND MAIN EEL.SDR 2007UALA00378Skin · scratchedUPPER FUSELAGE OUTER SKIN SCRATCHED AT STA 288 S23L. MAJOR REPAIR. REMOVED DAMAGE, FABRICATED AND INSTALLED DOULBER, FILLER AND STRUCTURAL FILLER PER SRM 53-00-01 REPAIR 31 DETAIL XIX.SDR 2007UALA00418Plate · damagedFWD GALLEY DOOR BODY TORQUE TUBE LOWER HINGE UPPER STOP PLATE HAS A GAP. REPLACED UPPER AND LOWER TORQUE TUBE BEARINGS.SDR 2007UALA00347Nut Plate · brokenFWD GALLEY DOOR INTERIOR HANDLE TRIM CRACKED ALSO DOOR SLIDE ATTACH POINT HAS BROKEN NUT PLATE. MAJOR REPAIR. REMOVED AND REPLACED DOOR HANDLE COVER PER MM 52-41-31. ALSO, REPLACED NUT PLATE PER SRM 51-40-02.SDR 2006UALA01895Collar · brokenTHE R1 DOOR GIRT BAR COLLAR BROKEN. REPLACED THE GIRT BAR SLEEVE.SDR 2006UALA01647Seat · failedFOUND LOW BOTTLE PRESSURE. CAUSED BY BALL SEAT LEAKING. REPLACED BALL SEAT.SDR 2006UALA01583Wire Harness · damagedWITH APU SHUTDOWN, THE APU DET INOP LIGHT ON AND 5 MINS LATER THE APU FIRE WARNING LIGHT AND BELL CAME ON. FOUND APU FIRE DETECTION LOOP HARNESS SHORTED. REPLACED APU FIRE DETECTION LOOP HARNESS.SDR 2006UALA01447Skin · dentedFOUND FUSELAGE DENT AT RT FWD SIDE OF STR 21R BETWEEN STA 240-250. FOUND 12 IN SCRIBE MARK AT LAP JOINT LWR SKIN. FABRICATED AND INSTALLED DOUBLER AND TRIPLER REPAIR.SDR 2005UALA01331Window · crackedL4 WINDOW CRACKED EN ROUTE. L4 WINDOW MIDDLE PANE SHATTERED, REPLACED WINDOW PER MM 56-11-31.SDR 2005UALA00977Rod · out of adjustDOOR 1R HANDLE MOVES IN FLIGHT. *S/D* ADJUSTED COCKING ROD AND LATCH FITTINGS AND STOP PINS. REF MM 52- 00-96-0100A AND MM 52-41-00.SDR 2005UALA00932Floorbeam · corrodedCABIN FLOOR BS 312 LBL 1 AND LBL 6 SMALL AREA OF CORROSION ON UPPER SURFACE OF FLOORBEAM.SDR 2005UALA00931Bulkhead · gougedAFT PRESSURE BULKHEAD HAS SEVERAL GOUGES AND SCRATCHES AT UPPER ELECTRICAL CONDUIT THROUGH LT SIDE LBL 5 TO LBL 3 WL 84.SDR 2005UALA00914Shear Tie · dentedEXTERNAL FUSELAGE STA 807 BETWEEN 28L AND 28R HAS A DENT AND SHEAR TIE BENT AT RADIUS.SDR 2005UALA00913Door Frame · corrodedR1 DOOR FRAME STA 296 RBL 54 CORRODED, S17R, WL 208.SDR 2005UALA00893Door Frame · corrodedFWD GALLEY DOOR STUB FRAME AT STA 296 AND RBL 54 CORRODED AT STRINGER S-17R AND WL 208.SDR 2005UALA00885Frame · crackedFWD GALLEY DOOR FRAME CRACKED AFT SIDE LOWER STOP FITTING.SDR 2005UALA00884Frame · crackedFWD GALLEY DOOR AFT FRAME IS CRACKED AT 3RD AND 4TH STOP FITTING CUTOUTS.SDR 2005UALA00869Floorbeam · corrodedCABIN FLOOR, STA 294.5 LBL 7, FLOORBEAM UPPER SURFACE, CORROSION.SDR 2005UALA00868Support · wornEE ACCESS DOOR CUTOUT, RT DOOR CUTOUT, SUPPORT FRAME STR 27R STA 338 IS WORN ABOVE DOOR LATCH FITTING.SDR 2005UALA00867Floorbeam · corrodedCABIN FLOORBEAM TOP CORRODED IN SEVERAL PLACES.SDR 2005UALA00847Structure · dentedAFT CARGO DOOR HAS SEVERAL OVERLAPPING DENTS AND SKIN IS DAMAGED ON FWD SIDE. INSTALLED A REPAIR DOUBLER 53 BY 48 INCHES REF SRM 52-00-01 AND SRM 51-00-01 FIG 202.SDR 2005UALA00846Angle · corrodedAFT GALLEY DOOR THRESHOLD ZEE ANGLE CORRODED STA 978 TO 984 RBL 62.5 STR 17 WL 208.SDR 2005UALA00845Floor Support · corrodedCABIN FLOOR SUPPORT AT AFT ENTRY DOOR HAS CORROSION STA 957-986 LBL 62.5 WL 208 AND LBL 63.0 WL 208.SDR 2005UALA00815Stringer Clip · crackedAFT PIT STA 907 STR 24R STRINGER CLIP BENT AND CRACKED. REMOVED AND REPLACED STRINGER CLIP.SDR 2005UALA00814Stringer Clip · bentAFT PIT STA 727D STR 20L STRINGER CLIP BENT AND CRACKED. REMOVED AND REPLACED STRINGER CLIP.SDR 2005UALA00104Unknown · unknownRETURNED TO SFO DUE TO PRESSURIZATION PROBLEM. FOUND EXCESSIVE LEAK AROUND E&E COMPARTMENT DOOR. REPLACED E&E COMPARTMENT DOOR SEAL.SDR 2001UALA02313Panel · departedSERVICE PANEL DEPARTED NR 2 ENGINE ON ROTATION. REINSTALLED PANEL. INSPECTED AREA FOR DAMAGE. NO DEFECTS NOTED.SDR 2001UALA02103Skin · damagedFORWARD PIT DOOR HAS EXTERIOR SKIN DAMAGED. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER.SDR 2001UALA02102Shear Tie · crackedSTRINGER 12R AT STA 344 SHEAR TIE CRACKED AFT OF DOOR R1 CENTER LINE. MAJOR REPAIR ACCOMPLISHED. REPLACED THE SHEAR TIE AT STRINGER 12R STA 344.SDR 2001UALA00177Circuit Breaker · malfunctionedNOSE GEAR UNSAFE LIGHT ON WHEN THE GEAR WAS EXTENDED FOR LANDING. SUPPLEMENTAL DATA UPDATE RESET BREAKER C404 AND NORMAL GEAR INDICATION RETURNED. REPLACED THE BREAKER AS A PRECAUTION.SDR 2000UALA00216Indicator · malfunctionedNR 1 ENGINE LOST 9 - 10 PERCENT OF THRUST FROM TARGET CLIMB N1. *S/D* REPLACED THE NR 1 N1 INDICATOR.SDR 97UAL900343Connector · looseAFT 5 FEET OF EMERGENCY FLOOR LIGHTS OUT. SECURED LOOSE CONNECTOR, OPS CHECK GOOD.SDR 95UAL737068Eel · inopEMERGENCY ESCAPE PATH LIGHT STRIPS INOP IN AFT CABIN AND CARPET IS WET. REPLACE EMERGENCY ESCAPE PATH LIGHT AND DRIED CABLE. CHECKS OK.
Back to N327UA, cancelled Aug 10, 2012