N337UA, cancelled Apr 27, 2009
Service difficulty reports · 47
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N337UA' AND deregistration_id = 'N337UA-2009-04-27' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N337UA' AND deregistration_id = 'N337UA-2009-04-27' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA03279Overheat Loop · faultyFOUND WING OVERHEAT LOOP M1204 BAD. SUSPECT IMPROPERLY INSTALLED. REPLACED RT OVERHEAT LOOP ENGINE PYLON IAW MM26-18-11. OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03003Light · contaminatedEMERGENCY EXIT LIGHTS STRIP INOP. FOUND MOISTURE CONTAMINATION. REMOVED MOISTURE, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02976Light · inoperativeEMERGENCY EEL FLOOR LIGHTS INOP FROM 12ABC TO 16ABC, ALSO GALLEY STRIP. SUSPECT FAULTY LIGHT SECTION. REPAIRED LIGHT SECTION, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA00896Sign · out of positionFOUND DOOR 2R FWD EXIT SIGN FELL OFF. REPLACED LIGHT ASSY.SDR UALA2008111300794Transmitter · faultyFLIGHT DIVERTED DUE TO A FLAP ASYMMETRY PROBLEM. FAULTY FLAP POSITION TRANSMITTER. REPLACED LT FLAP POSITION TRANSMITTER.SDR 2008UALA00794Flap · malfunctionedFLIGHT DIVERTED DUE TO A FLAP ASYMMETRY PROBLEM.SDR 2008UALA00143Smoke Detector · faultyFWD LAV SMOKE DETECTOR ALARMS INTERMITTANTLY. REPLACED SMOKE DETECTOR.
SDR 2007UALA03988Control Panel · faultyDISCHARGE LIGHT, NR 1 ENGINE, LT BOTTLE, DOES NOT ILLUMINATE WITH MASTER DIM TEST. REPLACED ENGINE AND APU FIRE CONTROL PANEL.SDR 2007UALA02550Connector · faultyEEL FLOOR LIGHTING INOP FROM ROW 17 ON BACK. [07-27-07] FOUND CONNECTIONS FOR EEL LIGHTS WET. CLEANED AND DRIED CONNECTIONS. OPS CHECK NORMAL.SDR 2007UALA02243Battery · dischargedCREW REPORT: AC FOUND WITH BATTERY DEAD AND BATTERY C/B POPPED. RESET AND POPPED AGAIN. FOUND FAULTY BATTERY AND BATTERY CHARGER. REPLACED BATTERY AND BATTERY CHARGER. NO FAULTS FOUND ON BOTH THE BATTERY AND BATTERY CHARGER.SDR 2007UALA01402Structure · damagedFORWARD CARGO DOOR GAP BETWEEN FORWARD CARGO DOOR AND THRESHOLD HAS A 1 INCH SCRIBE 0085" DEEP. MAJOR REPAIR ACCOMPLISHED: REPAIRED BLENDED SCRIBE AREA & INSTALLED REPAIRED DOUBLER.SDR 2007UALA01401Door Frame · burnedLOWER LIP OF EXTERNAL POWER CONNECTOR DOOR FRAME HAS A HALF INCH BURN-OFF ON METAL FRAME. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED INTERNAL DOUBLER & ANGLE REPAIR.SDR 2007UALA01391Door Frame · crackedFWD CARGO DOOR CUTOUT AFT FRAME WEB HAS TWO EACH CRACKS AT LWR DOOR STOP FITTING FASTENER HOLES. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE. FABRICATED & INSTALLED EXTERNAL NESTED ANGLE REPAIRS.SDR 2007UALA01339Screw · looseFWD GALLEY DOOR EVAC SLIDE GIRT BAR FWD STOW BRACKET ON COVER HAS TWO LOOSE SCREWS. ALSO, TOO MUCH MATERIAL IS HANGING OUT OF THE CONTAINER. [SUP 05-16-07] SECURED SCREWS AND ADJUST MATERIAL.SDR 2007UALA00739Wire · brokenEMERGENCY EXIT LIGHTS NEAR AFT GALLEY INOP AND A PLUG SEEMS DISCONNECTED. REPAIRED BROKEN WIRE AT AFT GALLEY LAST LIGHT STRIP FOR PERMANENT REPAIR. OPS GOOD.SDR 2006UALA01941O-Ring · pinchedB HYDRAULIC SYSTEM LOW PRESSURE LIGHT AND QUANITY LIGHT. FOUND LEAK AT PRESSURE SIDE OF EDP AT NIPPLE BY CASE. REPLACED PINCHED O-RING AND SERVICED HYDRAULICS TO FULL.SDR 2006UALA01731Charger · inoperativeFLOOR LEVEL EMERGENCY EXIT SIGN AT 1L INOP. REPLACED BATTERY AND CHARGER.SDR 2006UALA01432Battery · inoperativeEMERGENCY LIGHTS BATTERY PACK ABOVE SEAT 15 ABC IS INOP. REPLACED BATTERY PACK.SDR 2006UALA01122Power Cable · inoperativeONE EEL LIGHT STRIP INOPERATIVE AT ROW 16ABC.SDR 2006UALA00161Rivet · crackedFOUND 5 EA CONFIRMED CRACKED RIVETS AROUND PERIMETER OF 1 LT, 2 LT, 3 LT & 5 LT FLIGHT DECK WINDOWS. REPLACED CRACKED RIVETS PER SRM 51-40-02.SDR 2006UALA00140Keelbeam · damagedRIGHT KEEL BEAM LOWER CHORD AT RL 6.3 OUTBOARD FLANGE AT STA 706-727. BLENDED CORRODED AREA. NDT FOR CRACKS. TRIMMED OUT AREA OF LOWER OTBD CHORD PER AAR EA I060044. SPOT FACED HOLES PER EA AND FABRICATED & INSTALLED ANGLE REPAIR, TAPERED FILLERS, WASHERS ANDSDR 2006UALA00139Bulkhead · crackedCRACKS FOUND BETWEEN S3L-S5L AND S5L-S7L STA 1016 AFT BULKHEAD WEB. REMOVED CRACKS, ACCOMPLISHED DOUBLER, TRIPLER, AND TRIPLER FILLER REPAIR PER SRM 53-80-08 REPAIR 7 .SDR 2006UALA00126Skin · damagedFWD GALLEY DOOR 1R FWD FRAME UPPER EDGE SKIN HAS SMALL WEAR MARK. FABRICATED & INST'D REPAIR DOUBLER PER AAR EA1060064. NO FURTHER FINDINGS, O.K. FOR SERVICE.SDR 2006UALA00112Stop Fitting · crackedFWD GALLEY DOOR S/N 1074 - STOP FITTINGS NR 3 & 4 CUTOUTS ARE CRACKED (AFT FRAME). REMOVED AFT FRAME AND INSTALLED NEW FRAME AND ASSOCIATED FITTINGS AND HARDWARE PER SRM 51-40-02. NO FURTHER FINDINGS, O.K. FOR SERVICE.SDR 2006UALA00061Keelbeam · corrodedAIR CONDITIONING BAY STATION 500D + 2 INCHES TO STA 500D + 6 INCHES KEEL BEAM LT LOWER CHORD CORRODED. REMOVED CORROSION & CHECKED FOR CRACKS BY NDT. FABRICATED REPAIR ANGLES & INSTALLED NESTED ANGLES REPAIRS PER SRM 53-30-12.SDR 2006UALA00055Crease Beam · corrodedAFT ENTRY DOOR THRESHOLD CREASE BEAM INNER CHORD CORRODED STA 968 TO 969 LBL 52 TO LBL 53. REMOVED & REPLACED CREASE BEAM REF SRM 51-40-02.SDR 2006UALA00054Skin · dentedDENT IN RIGHT HORIZONTAL STAB LEADING APPROX TWO TO THREE FEET INBOARD OF TIP. REMOVED DAMAGE & VERIFIED CONTAINMENT USING NDT. FABRICATED & INSTALLED FLUSH REPAIR REF SRM 55-10-01.SDR 2006UALA00053Floorbeam · corrodedAFT CABIN STA 947 FROM LBL 25 TO RBL 21 FLOORBEAM UPPER CHORD CORRODED AROUND 5 EA FASTENER HOLES. BLENDED CORRODED AREAS & FOUND BLEND OUT OF LIMITS. FABRICATED & INSTALLED NESTED ANGLE REPAIRS TO UPPER CHORD OF FLOOR BEAM REF MM 53-10-95.SDR 2006UALA00052Splice · crackedSTATION 360 STRINGER 14L SPLICE LOWER SIDE CRACKED. REMOVED & RPL CHANNEL SPLI CE REF SRM 51-40-02.SDR 2006UALA00051Floor Support · corrodedFORWARD CABIN FLOOR STRUCTURE CORRODED AT STA 289 TO STA 328 FROM RBL 51 TO RBL 59. REMOVED CORROSION & FOUND BLENDED AREAS OUT OF LIMITS. REPLACED TWO Z-ANGLED CHORDS REF SRM 53-10-15 & SRM 51-40-02.SDR 2006UALA00009Frame · crackedCABIN OVERWING FRAME BS 616L INNER CHORD CRACKED AT LOWER END JUST BELOW CREASE BEAM. REMOVED CRACK ACCOMPLISHED FILLER AND ANGLE REPAIR PER MM 53-11-89.SDR 2003UALA00716Wheel · separatedON LANDING DCA, NOSE LANDING GEAR COLLAPSED. UPON ROTATION IN ORD, THE NOSE WHEEL ASSEMBLIES DEPARTED THE AXLE. AIRCRAFT LANDED ON THE AXLE IN DCA. CAUSE OF FAILURE WAS THE REPAIR SHAFT, UAL P/N 3F13178-2. IT WAS DETERMINED THAT THE REPAIR SHAFT THREADS WERE SDR 2001UALA02409Skin · dentedRIGHT HAND HORIZONTAL STABILIZER LEADING EDGE DENTED 5 FEET FROM OUTBOARD END. MAJOR REPAIR ACCOMPLISHED. ACCOMPLISHED FLUSH REPAIR.SDR 2001UALA02388Frame · crackedBODY STATION 616 BELOW STRINGER 17R INNER CHORD CRACKED ON FRAME. MAJOR REPAIR ACCOMPLISHED, CRACK REPAIRED.SDR 2001UALA02381Web · crackedFORWARD CARGO DOOR CLOSING WEB CRACKED AT STRINGER 26R BODY STATION 496. MAJOR REPAIR ACCOMPLISHED, CRACK REPAIRED.SDR 2001UALA02380Stringer · crackedBODY STATION 188 STRINGER 17R CORD CRACKED. MAJOR REPAIR ACCOMPLISHED, REPAIRED STRINGER.SDR 2001UALA02369Floorbeam · crackedBODY STATION 520 FLOOR BEAM WEB CRACKED AT LBL 24.75. MAJOR REPAIR ACCOMPLISHED, ACCOMPLISHED REINFORCEMENT REPAIR.SDR 2001UALA02368Skin · dentedEXTERNAL FUSELAGE STATION 240 8 INCHES ABOVE LOWER SKIN LAP DENTED. MAJOR REPAIR ACCOMPLISHED, ACCOMPLISHED DOUBLER REPAIR.SDR 2001UALA02349Doubler · chafedRT WING LEADING EDGE SKIN HAS CHAFING WEAR ON SCAB PATCH JUST INBOARD (16 INCHES) OF NR 2 ENGINE. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED NEW DOUBLER AND FILLER.SDR 2001UALA02316Skin · gougedAFT CARGO DOOR CUT-OUT, FORWARD EDGE STATION 797 AND STRINGER 22R TO 23R, EXTERNAL SKIN GOUGES ON EDGE. MAJOR REPAIR ACCOMPLISHED. REPAIRED AREA WITH DOUBLER.SDR 2001UALA01347Odor · detectedUNKNOWN ODOR IN CABIN REPORTED BY CABIN CREW. *S/D* NO CAUSE DETECTED FOR ODOR. CHECKED PACK SYSTEMS, PNEUMATIC DUCTS, ELECTRONIC COMPARTMENT, CABIN LIGHTING, AND GALLEYS EQUIPMENT WITH NO DEFECTS NOTED.SDR 2001UALA01338Floor Support · corrodedAFT PIT FLOOR SUPPORT HAS CORROSION AT BS 727D. ACCOMPLISHED ANGLE REPAIR. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA01337Floor Support · corrodedAFT PIT FLOOR SUPPORT ANGLE CORRODED AT BS 727D+6, 4TH INBD FROM RT SIDE. REMOVED DAMAGE. ACCOMPLISHED ANGLE REPAIR. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA01330Skin · damagedFUSELAGE SKIN DAMAGED AT BS 190, BETWEEN STR 17L AND STR 18L. INSTALLED FLUSH PATCH WITH INTERNAL DOUBLER. MAJOR REPAIR ACCOMPLISHED.SDR 97UAL900877Overheat Det · shortedRIGHT HAND WING BODY OVERHEAT LIGHT CAME ON INTERMITTENTLY ONE MINUTE AFTER TAKEOFF. *S/D* TROUBLESHOOTING INDICATED THAT RIGHT-HAND WING LEADING EDGE OVERHEAT DETECTOR ELEMENT WAS SHORTED TO GROUND. REPLACED DETECTOR AND PERFORMED ENGINE RUN. SYSTEM CHECKSDR 96UAL900375Battery Pack · dischargedEMERGENCY ESCAPE PATH LIGHTING INOP IN FORWARD CABIN. REPLACED BATTERY PACK, CHECKS OK.SDR 96UAL900182Accessory Unit · failedNR 4 LEADING EDGE FLAP WOULD NOT RETRACT. SUPPLEMENTAL DATA UPDATE: REPLACED FLAP/SLAT POSITION SWITCH ACCESSORY UNIT. SYSTEM CHECKED GOOD. FAILURE OF THE ACCESSORY UNIT COULD NOT BE VERIFIED BY THE HOME SHOP.