N343EN, cancelled Nov 16, 2018
Service difficulty reports · 114
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N343EN' AND deregistration_id = 'N343EN-2018-11-16' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N343EN' AND deregistration_id = 'N343EN-2018-11-16' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2018050200093Wire · damagedEMERGENCY FLOOR LIGHT AT ROW 9DF NEEDS RE-SPLICED. RE-SPLICED BROKEN WIRE GOING TO EMERGENCY FLOOR LIGHT AT ROW 9DF AND COVERED WITH SLEEVE.SDR HNAA2018032100063Bulb · inoperativeEMERGENCY LIGHT IS INOPERATIVE AT SEATS 6DF. REMOVED AND REPLACED THE BULB.SDR HNAA2018031200057Switch · dirtyAUTOFEATHER WILL NOT ARM ON TAKE OFF ROLL AT 85% TORQUE. CLEANED THE SWITCHES ON POWER LEVERS. GROUND RAN AIRCRAFT, OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2017100200341Unknown · unknownWITH THE NR 2 ENGINE RUNNING, AND GPU DISCONNECTED, ALL ACFT LIGHTS EXTINGUISH. NR 2 DC GENERATOR DOES SHOW LOAD. STARTED THE NR 1 ENGINE, FLT DECK LIGHTS ILLUMINATED AND CABIN EXIT LIGHTS WOULD NOT TURN ON AND FA UNABLE TO TURN ON EMERGENCY LIGHTS. EMERGENCSDR HNAA2017092900335Lamp · inoperativeEMERGENCY EXIT LIGHT AT CENTER AISLE CEILING IS INOPERATIVE. REPLACED THE LAMPS. OPS CHECKED GOOD.SDR HNAA2017092900337Socket · burnedOVERHEAD LIGHT AT SEAT 2DF HAD A BURNED ODOR. PERFORMED AN INSPECTION TO THE OVERHEAD LIGHT. FOUND THE LIGHT SOCKET BURNED.SDR HNAA2017091400305Cover · detachedFLOOR EMERGENCY LIGHT AT ROW 5 & 6, FOUND THE WIRES PULLED OUT AND PLASTIC COVER SECTION DETACHED. REPLACED THE LAMPS. INSTALLED THE PLASTIC COVERS. OPS CHECKED GOOD. OKAY FOR SERVICE.SDR HNAA2017081800278Contactor · failedWHEN STARTING NR 2 ENGINE, A BUSS FAULT OCCURED AND ENGINE STARTED. START SWITCH RETURNED TO NEUTRAL. MAIN BATTERY LOAD OF 1.99 AND ELECTRICAL ODOR IN FLT DECK. MAIN BATTERY TEMP IN YELLOW. NR 2 DC GENERATOR DID NOT COME ON LINE. R & R THE NR 2 START CONTSDR HNAA2017081700276Starter Gen · faultyON START DC GEN DID NOT COME ONLINE, SMOKE REPORTED FROM NR 2 NACELLE. SHUT DOWN USING T-HANDLE AND FIRED BOTH BOTTLES. R&R NR 2 STARTER/GENERATOR. START/RUN/OPS AND LEAK CHECK GOOD. OK FOR SERVICE.SDR HNAA2017041700119Light · out of positionONE CABIN FLOOR EMERGENCY LIGHT IS MISSING, SUSPECT IT TO BE UNDER THE FLOOR. REMOVED CENTER FLOOR FROM ROWS 1-12 FOUND LIGHT UNDER FLOOR AT ROW 12. SECURED LIGHTS AND SECURED THE FLOOR PANELS FROM ROW 1-12 WITH RETAINED HARDWARE.SDR HNAA2016121900346Connector · failedNR 1 ENGINE FUEL GAUGE FLUCTUATING ON THE GROUND. INSPECTED WIRES AT GAUGE CONNECTOR PLUG. PINNED THE CONNECTOR PLUG AT HE FUEL TEMP BULB. GROUND RAN AIRCRAFT. OPS CHECKED GOOD.OK FOR SERVICE.SDR HNAA2016111100348Apu · failedAPU FAILED AFTER 30 MINUTES. CHECK FIRE DETECTOR, LIGHT ILLUMINATED. MAINTENANCE VERIFIED BOTTLE DISCHARGED AND RED FUSELAGE DISC BLEW.SDR HNAA2016050600135Lamp · inoperativeCLOSE CABIN FLOOR EMERGENCY LIGHT AT SEAT 9D-F WILL NOT ILLUMINATE. REMOVED FLOOR LENS COVER R & R LAMP IN MODULE ASSY AND RE-INSTALLED AND SECURED FLOOR LENS COVER, PN OL3071BPEGPL.SDR HNAA2016041200101Warning Horn · activatedT/O WARNING SOUNDED AT T/O POWER. REJECTED T/O, CYCLED FLAPS, OPS CK NORMAL.SDR HNAA2016032900091Lens · broken3RD FROM FRONT CEILING EMERGENCY LIGHT IS BROKEN, LENS WILL NOT STAY IN PLACE. R & R THE LENS.SDR HNAA2016030200068Warning Light · activatedPUSHER SYSTEM FAIL. CAUTION LIGHT ILLUMINATED ON TAXI. DE-ACTIVATED PUSHER SYS IAW APPROXIMATELY 1, 27-9.SDR HNAA2016022200052Bulb · inoperativeEMERGENCY EXIT SIDEWALL LIGHTS ARE INOPERATIVE. R & R BULBS ON SIDEWALL PANEL.SDR HNAA2016022200051Bulb · inoperativeMULTIPLE CEILING EMERGENCY EXIT LIGHTS ARE INOPERATIVE. R & R EMERGENCY LIGHT BATTERY PACK AND BULBS.SDR HNAA2016022200050Bulb · inoperativeRIGHT FORWARD EMERGENCY EGRESS LIGHT IS INTERMITTENT, THEN INOPERATIVE. R & R BULB, EMERGENCY LIGHT BATTERY AND POWER SUPPLY IAW 33-51-05 AT PS2.SDR HNAA2016021700037Skin · bulgedSKIN BULGED OUT AROUND RIVETS ON FUSELAGE BELLY ON AFT END OF BLANKING PLATE AT BS 358, SUGGESTING POSSIBLE CORROSION. FABRAICATED EXTERNAL AND EXTERNAL DOUBLER AND INSTALLED AT STA 358 ON BELLY IAW EO8-53-16-0105 AND RD8 53 14545.SDR HNAA2016020100029Bulb · burned outEMERGENCY EXIT LIGHTS BURNED OUT ON CEILING PANEL C1. R & R BULBS, OPS CHECKED GOOD.SDR HNAA2016020100028Bulb · inoperativeEMERGENCY LIGHT ON CABIN CEILING PANEL IS INOPERATIVE. R & R BULBS. OPS CHECKED GOOD.SDR HNAA2015120100357Bulb · inoperativeEMERGENCY LIGHTS ARE INOPERATIVE AT OW 6DF, 5TH FROM AFT END. R & R BULBS AND EMERGENCY LIGHT AT ROW 6DF. OPS CHECKED GOOD.SDR HNAA2015111800339Unknown · odorF/A REPORTS, ELECTRICAL BURNING SMELL DURING FLIGHT IN CABIN, THEN SHORTLY DISSAPATED.....PERFORMED INSPECTION, SUSPECTED ROW 6 AC OVERHEAD LIGHT AT FAULT SEE SEQUENCE 2 FOR MEL.SDR HNAA2015110900329Bulb · inoperative3RD EMERGENCY LIGHT IS INOPERATIVE. R & R BULB. OPS CHECKED GOOD.SDR HNAA2015101900304Apu · odorRAMP REPORTED BURNING ODOR IN CARGO BAY AREA, WHEN APU WAS STARTED. INSPECTED CARGO BAY. NO EVIDENCE OF SMOKE OR FIRE. FOUND OIL VAPOR COMING FROM APU VENT MAST. SERVICE APU OIL. GROUND RAN APU. OPERATED APU BLEEDS, NO LEAK OR ODOR NOTED. AIRCRAFT OK FOR SSDR HNAA2015101900303Unknown · odorFUEL ODOR IN CABIN AND COCKPIT AFTER APU START. INSPECTED ACFT AND GROUND RAN BLEED SYSTEM WITH ENGINE AND APU BLEEDS. FOUND FUEL ODOR WITH APU BLEED ONLY. NO SIGN OF FIRE OR OVERHEAT IN APU COMPARTMENT.SDR HNAA2015052500167Battery Pack · inoperativeRIGHT AFT EGRESS LIGHT AND AFT EXIT CEILING LIGHT IS OUT. R & R EMERGENCY LIGHT BATTERY PS6 IAW WC 33-50-05R. OPS CHECKED GOOD.SDR HNAA2015041300128Propeller · vibrationVIBRATION FELT FROM NR 2 ENGINE BELOW START FEATHER AND DURING ENGINE SHUTDOWN. R & R NR 2 PROP ASSY IAW WC 61-10-06R, 61-00-09R, 61-10-07R AND 61-10-00. GROUND RAN ACFT. OPS AND LEAKED CHECKED GOOD.SDR HNAA2015030900079Control Unit · malfunctionedWHILE APPLYING TAKEOFF POWER, NR 2 PROP FEATHERED. ARM LIGHT WAS NOT ILLUMINATED. R & R NR 2 ENGINE TSCU. OPS CHECKED GOOD IAW PIEDMONT RUN UP MANUAL.SDR HNAA2015030900078Warning Light · false activationAFTER TAKEOFF AND AUTOFEATHER DISENGAGED. ARM LIGHT REMAINED ILLUMINATED UNTIL DESCENT AND POWER REDUCED, ARM LIGHT EXTINGUISHED. CYCLED SWITCH SEVERAL TIMES. STATIC CHECK AND GROUND RAN ACFT. OPS CHECKED GOOD AT THIS TIME.SDR HNAA2015030400075Bulb · inoperativeEMERGENCY FLOOR PATH LIGHT IS INOPERATIVE AT ROW 1. R & R BULB FOR EMERGENCY FLOOR PATH LIGHT AT ROW 1. OPS CHECKED GOOD.SDR HNAA2015022300060Brake · smokePASSENGER REPORTED LT BRAKE SMOKING. INSPECTED BRAKE, NO DEFECTS NOTED. OK FOR SERVICE.SDR HNAA2015021300040Power Supply · malfunctionedROW 11 EXIT DOOR SIGN FLICKERED. R & R PS-3 POWER SUPPLY BASE. OPS CHECKED GOOD. GROUND RAN ACFT. OPS CHECKED GOOD WITH PROP HEAT ON. OPS NORMAL. OK FOR SERVICE.SDR HNAA2015020200031Warning Light · illuminatedRIGHT AC BUSS C/L CAME ON AT CLIMBOUT WITH ASSOC. C/L'S. R & R RT AC GCU AND OPS CHECKED GOOD DURING 15 MINUTE RUN.SDR HNAA2015011600018Brush Block · damagedEMERGENCY LIGHTS FLICKERED IN FLIGHT. R & R NR 1 AND NR 2 BRUSH BLOCK ASSYS IAW MM 61-10-11. COMPLIED WITH EMERGENCY LIGHT SYSTEM, OPS CHECK WC 33-50-03Q. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2015010500003Bulb · dimEMERGENCY LIGHT AT FORWARD EMERGENCY EXIT SIDEWALL IS DIM. R & R THE BULBS. OPS CHECKED GOOD.SDR HNAA2015010500002Bulb · dimEMERGENCY LIGHT BY PAX DOOR IS DIM. R & R THE BULBS, OPS CHECKED GOOD.SDR HNAA2014123100392Bulb · inoperativeEMERGENCY LIGHT DOES NOT ILLUMINATE WHEN ON. R & R BULB, OPS CHECKED GOOD.SDR HNAA2014123100391Control Box · malfunctionedAFTER TAKEOFF, CEILING AND WALL EMERGENCY LIGHTS FROM ROW 4 BACK FLICKERED ON AND OFF. R & R EMERGENCY LIGHT CONTROL BOX, OPS CHECKED GOOD IAW MM 33-51-00.SDR HNAA2014122400379Battery Pack · inoperativeEMERGENCY EXIT AND OVERHEAD EMERGENCY LIGHTS AT ROW 11 ILLUMINATED IN FLIGHT. R & R POWER SUPPLY AND BATTERY A PS4. PERFORMED OPS CHECKED IAW MM 33-51-00. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2014122300377Power Supply · malfunctionedEMERGENCY LIGHTS AFT OF ROW 4 ILLUMINATE INTERMITTENTLY. R & R EMERGENCY LIGHT BATTERIES AND POWER SUPPLIES AT LOCATION PS6 AND PS7 IAW MM 33-51-05. OPS CHECKED GOOD.SDR HNAA2014121000355Battery Pack · inoperativeWHILE IN FLIGHT, EMERGENCY SIGN AT ROW 11 ISLE LIGHTS, INCLUDING ROWS 4, 7 AND 10 FLICKERED INTERMITTENTLY. R & R POWER SUPPLY AND BATTERY AT PS6 IAW MM 33-51-05. GROUND RAN ACFT. CHECKED WITH PROP HEAT AND BOTH TIMERS ABOVE AND BELOW. OPS CHECKED GOOD. RESDR HNAA2014111700326Light · malfunctionedEMERGENCY LIGHTS FLICKER AND ARE DIM.SDR HNAA2014080400220Brush Block · damagedEMERGENCY LIGHTS FLICKERED WITH PROPELLER HEAT ON. R & R NR 1 BUSH BLOCK. CLEARED NR 2 BRUSH BLOCK CONNECTOR AND SLIP RINGS. GROUND RAN ACFT. PROPELLER HEAT OPS CHECKED GOOD, NO FLICKERING OF EMERGENCY LIGHTS.SDR HNAA2014061600181Brush Block · corrodedEMERGENCY LIGHTS FLICKERING INTERMITTENTLY DURING FLIGHT. FOUND ALL HEATER LEADS ON NR 1 PROPELLER CORRODED. R & R ALL HEATER LEADS IAW MM 61-10-00 AND BRUSH BLOCK. GROUND RAN . OPS CHECKED GOOD. ACFT OK FOR SERVICE.SDR HNAA2014061300178Brush Block · corrodedEMERGENCY LIGHTS FLICKERED INTERMITTENELY IN FLIGHT. FOUND LEADS ON NR 1 PROPELLER FILLED WITH WATER AND CORRODED. R & R LEADS ON NR 1 PROPELLER HS MM 61-10-00. R & R NR 1 BRUSH BLOCK IAW 61-10-00, REINSTALLED BOTH PROP SPINNER. OPS CHECKED GOOD. OK FOR SSDR HNAA2014041400131Clamp · looseBURNING ODOR IN AREA OF ROW 7 WITH HOT OVERHEAD PANELS. INSPECTED AND FOUND WING ISOLATION CHECK VALVE CLAMPS LOOSE. TORQUED AS REQUIRED. NO FURTHER LEAKS NOTED OR ODOR IN CABIN. OK FOR SERVICE.SDR HNAA2014032600108Wire · chafedRIGHT AC BUSS CAUTION LIGHT, RT TRU AND ELEVATOR HORN HEAT CAUTION LIGHTS ILLUMINATED IN FLIGHT. CREW RETURN TO FIELD. MAINTENANCE FOUND WIRE CHAFED AGAINST NR 2 AC GCU. REPAIRED WIRE 20003A18B-1. R & R NR 2 AC GCU. GROUND RAN ACFT. NO DEFECTS NOTED. OK SDR HNAA2014032100098Wire · brokenEMERGENCY FLOOR PATH LIGHT IS INOPERATIVE AT ROW 9. FOUND BROKEN WIRE AND REPAIRED IAW AMM 20-4-07. OPS CHECKED GOOD.