N343TE, cancelled Jan 17, 2019
Service difficulty reports · 44
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N343TE' AND deregistration_id = 'N343TE-2019-01-17' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N343TE' AND deregistration_id = 'N343TE-2019-01-17' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RAIA0002023Switch · failed7209 - FWA - LEFT FUEL PRESSURE CAPTION ILLUMINATED ON TAKEOFF ROLL ALL OTHER ENGINE INDICATIONS NORMAL. MAINTENANCE INSPECTED AND DEFERRED LEFT ENGINE FUEL PRESSURE CAPTION. MAINTENANCE REPLACED LEFT ENGINE FUEL PRESSURE SWITCH.SDR RAIA9912029Ammeter · fluctuated7470-STL- RIGHT AMMETER FLUCTUATES 20 TO 30 AMPS. MAINTENANCE DEFERRED AMMETER IAW MEL 24-1 CAT B. MAINTENANCE REPLACED RIGHT AMMETER.SDR RAIA9911006Tach Generator · failed7336 - STL - RIGHT RPM INDICATOR FAILED. MAINTENANCE REPLACED TACH GENERATOR ON RIGHT ENGINE.SDR RAIA9910026Tach Generator · failedSTL- RIGHT ENGINE RPM GAUGE INOP. MAINTENANCE REPLACED TACH GENERATOR ON RIGHT ENGINE.SDR RAIA9910052Socket · failedSTL- SMOKE SMELL IN COCKPIT IN FLIGHT. MAINTENANCE REPLACED LIGHT SOCKET ASSY AT SEAT 3A FOR THE OVERHEAD LIGHT.SDR RAIA9910013Line · failed7334 - STL - LOST ALL HYDRAULIC PRESSURE. MAINTENANCE REPLACED HYD LINE ON RIGHT SIDE OF AIRCRAFT.SDR RAIA9909009Tach Gen · failed7509-FWA - LEFT RPM GAUGE STUCK AT ZERO. MAINTENANCE REPLACED LEFT TACH GENERATOR.SDR RAIA990910Tach Generator · failedFLT 7444 - STL - RIGHT ENGINE RPM GAUGE INOPERATIVE. MAINTENANCE REPLACED TACH GENERATOR FOR RIGHT ENGINE. (M)SDR RAIA990908Hyd Pump · failedFLT 7533 - FWA - RIGHT ENGINE HYDRAULIC PRESSURE DROPPED TO ZERO. MAINTENANCE REPLACED RIGHT ENGINE HYD PUMP. (M)SDR RAIA990826Tach Generator · failedFLT 7030 - COU - RIGHT RPM GAUGE FLUCTUATING. MAINTENANCE REPLACED TACH GENERATOR ON RIGHT ENGINE. (M)SDR RAIA990522Radar · failedFLT 7465 - ALO - WEATHER RADAR INOPERATIVE. MAINTENANCE REPLACED RADAR R/T. (M)SDR RAIA990514Inverter · failedFLT 7394 - STL - ELECTRICAL SMELL IN COCKPIT. MAINTENANCE REPLACED INVERTER FOR ROOF PANEL LIGHTS IN COCKPIT. (M)SDR RAIA990437Rmi · failedFLT 7440 - STL - NR 1 CDI 30 DEGREES OFF. MAINTENANCE REPLACED NR 2 RMI. (M)SDR RAIA990107Indicator · failedCMI - FLT 7448 - CAPTAIN'S AIRSPEED INDICATOR INOPERABLE. MAINTENANCE REPLACED CAPTAIN'S AIRSPEED INDICATOR. (X)SDR RAIA981201Filter · failedFLT 7091 - SPI - RIGHT ENGINE SHUTDOWN ON IT'S OWN. FUEL CROSSFEED SWITCH WAS OPEN AND LEFT BOOST PUMP ON ONLY. MAINTENANCE PERFORMED EXTENSIVE ENGINE RUNS AND REPLACED RIGHT ENGIEN FUEL FILTER. (M)SDR RAIA981123Switch · failedFLT 7102 - STL - RIGHT BETA LIGHT ILLUMINATED ON TAKEOFF ROLL. MAINTENANCE REPLACED RIGHT BETA SWITCH. (M)SDR RAIA980611Hyd Pressure · failedFLT 7424 - STL - HYDRAULIC PRESSURE WENT TO ZERO, CREW PERFORMED EMERGENCY GEAR EXTENSION, IN WORK 6/25/98. (M)SDR RAIA980606Duct · failedSTL - FLT 7356 - AIRCRAFT WILL NOT PRESSURIZE ABOVE 1 PSID. MAINTENANCE INSPECTED AND REPLACED LEFT WATER SEPARATOR TO CABIN DUCT ASSEMBLY. (X)SDR RAIA971105Maxaret · failedFLT 7509 - STL - LEFT BRAKE FAILED ON TAXI OUT. MAINTENANCE REPLACED LEFT BRAKE MAXARET ANTI-SKID UNIT. (M)SDR RAIA970915Check Valve · failedSTL - FLT 7034 - RIGHT ENGINE DID NOT ACHIEVE TARGET TORQUE ON TAKEOFF ROLL. MAINTENANCE REPLACED RIGHT ENGINE PLENUM DRAIN CHECK VALVES. (X)SDR RAIA970508Connector · broken wireSTL - FLT 7434 - LEFT ENGINE WOULD NOT ACHIEVE TARGET TORQUE. MAINTENANCE REPAIRED WIRING AT LEFT TTL BYPASS VALVE CONNECTOR. (X)SDR RAIA970309Connector · broken wireSTL - FLT 7358 - CAPTAINS CDI NEEDLE IN HSI WILL NOT POINT TO STATION. MAINTENANCE REPAIRED BROKEN WIRE AT CAPTAINS HSI CANNON PLUG CONNECTOR. (M)SDR RAIA961209Prop Governor · out of adjustSTL - FLT 7344 - RIGHT ENGINE TAKEOFF RPM 99 PERCENT. MAINTENANCE ADJUSTED PROP GOVERNOR HIGH STOP. (M)SDR RAIA961104X-Screw · out of adjustBMI - FLT 7325 - LEFT ENGINE RPM 98.8 PERCENT. ADJUSTED SCREW X (PROP GOV HIGH). (M)SDR RAIA960813Transducer · stuckSTL - FLT 7364 - RIGHT ENGINE OIL PRESSURE INDICATION PEGGED OUT. MAINTENANCE REPLACED THE RIGHT OIL PRESSURE TRANSDUCER. (M)SDR RAIA960503Engine · low pwrEVV - FLT 7427 - LOW POWER NR 2 ENGINE. REPLACED ENGINE. (M)SDR RAIA960315Gasket · failedSTL - FLT 7031 - LEFT ENGINE TORQUE FLUCTUATES. MAINTENANCE REPLACED THE BLEED AIR GASKET, GROUND RUNS GOOD. (X)SDR RAIA960232Starter Gen · failedSTL - FLT NR 7050 - HIGH FREQUENCY VIBRATION ON NR 1 ENGINE. MAINTENANCE REPLACED NR 1 STARTER GENERATOR AND SPLINE ADAPTER GROUND RUN GOOD. (M)SDR RAIA960229Airspeed Ind · malfunctionedBRL - FLT NR 7051 - CAPTAINS AIRSPEED INDICATOR STUCK AT 90 KNOTS ON TAKEOFF. AIRCRAFT RELEASED FOR FERRY FLIGHT TO STL. CREW REPORTED PROPER OPERATION OF SYSTEM DURING FERRY FLIGHT. MAINTENANCE PERFORMED OPERATION CHECK, NO DEFECTS NOTED. (M)SDR RAIA960157Fire Loop · failedDEC - FLT NR 7301 - RIGHT ENGINE FIRE DETECTION SYSTEM SOUNDED, CREW FIRED BOTH FIRE BOTTLES AND SHUT DOWN ENGINE. MAINTENANCE FOUND NO EVIDENCE OF FIRE. RIGHT ENGINE FORWARD FIRE LOOP REPLACED, BOTTLES REPLACED, OPERATION CHECK GOOD. (M)SDR RAIA960106Fire Loop · failedSTL - FLT 7442 - RIGHT ENGINE FIRE WARNING ON RUNWAY BEFORE TAKEOFF, FLIGHT CREW FIRED FIRE BOTTLES AND EVACUATED AIRCRAFT. MAINTENANCE INSPECTED ENGINE AND FOUND NO EVIDENCE OF FIRE, MAINTENANCE THEN REMOVED AND REPLACED ZONE 1 FIRE LOOP, OPERATONAL CHECK GOSDR RAIA951043Nav Reciever · failedSTL - FLT NR 7316 - UNABLE TO RECEIVE COURSE INDICATION ON NR 1 AND NR 2 NAVS AFTER TAKEOFF. NR 2 EVENTUALLY RECEIVED HEADING INFORMATION. MAINTENANCE RERACKED NR 1 AND NR 2 NAV RECEIVERS. OPS CHECK GOOD. (M)SDR RAIA951039Beta Switch · faultySTL - FLT 7494 - RIGHT BETA WOULD NOT EXTINGUISH. MAINTENANCE REMOVED AND REPLACED RIGHT BETA SWITCH PERFORMED GROUND RUNS, OPS CHECK GOOD. (M)SDR RAIA951023Oil Cooler · failedDEC - FLT 7291 - LEFT OIL COOLER FLAP STUCK OPEN. MAINTENANCE REPLACED LEFT OIL COOLER ACTUATOR. SYSTEM CHECK GOOD. (M)SDR RAIA950848Tq Signal Cond · out of adjustSTL - FLT NR 7390 - ON TAKEOFF ROLL NR 1 ENGINE DID NOT MAKE TORQUE AND TTL DID NOT BYPASS FUEL-EGT WENT TO 670 DEGREES. MAINTENANCE RECALIBRATED LEFT ENGINE SIGNAL CONDITIONER. DEFERRED LT TTL AS PER MEL 76-2 CAT C. GROUND RUNS CHECK OK. (M)SDR RAIA950812Tq Signal Cond · out of adjustJLN - FLT NR 7060 - RT ENGINE DOES NOT MAKE TORQUE. MAINTENANCE ADJUSTED RT ENGINE TORQUE SIGNAL CONDITIONER AS PER GARRETT DSC SHEET. GROUND POWER RUNS REVEALED NORMAL ENGINE PARAMETERS. (M)SDR RAIA950623Tq Signal Cond · out of adjustSTL- FLT 7513 - BOTH ENGINES FAILED TO ACHIEVE TARGET TORQUE. MAINTENANCE ADJUSTED TORQUE SIGNAL CONDITIONERS. GROUND RUNS REVEALED NORMAL OPERATION. (X)SDR RAIA950622Propeller · out of adjustSTL - FLT 7071 - RT ENGINE DID NOT MAKE TORQUE. MAINTENANCE ADJUSTED RT PROPELLER BLADE ANGLE. GROUND RUNS GOOD. (X)SDR RAIA950610Eel Pwr Supply · failedSTL - RIGHT EXIT LIGHT AND CENTER OVERHEAD LIGHT WILL NOT ILLUMINATE WITH EMERGENCY LIGHTING ON. MAINTENANCE REPLACED EMERGENCY LIGHTING POWER SUPPLY. (M)SDR RAIA950437Release Valve · malfunctionedSTL - FLT NR 7316 - WHEN GEAR SELECTED UP, INTRANSIT LIGHT WOULD NOT EXTINGUISH. RESET HYDRAULIC BYPASS VALVE. (W)SDR RAIA950429Starter/Gen · inopSBN - FLT 7491 - THE NR 2 GENERATOR WENT OFF LINE. REPLACED STARTER GENERATOR. (Z)SDR RAIA950410Beta Switch · failedSTL - FLT 7422 - RIGHT BETA LIGHT CAME ON. MAINTENANCE REPLACED RIGHT BETA LIGHT SWITCH. GROUND RUNS AND LEAK CHECK GOOD. (M)SDR RAIA950320Gaskets · blownSTL - FLT 7308 - LEFT ENGINE FAILED TO ACHIEVE TARGET TORQUE. MAINTENANCE REPLACED LEFT ENGINE BLEED AIR GASKETS. GROUND POWER RUNS REVEALED NORMAL OPERATION. (X)SDR RAIA950125Switch · out of adjustFWA - FLT 7513 - THE PAX DOOR CAPTION ILLUMINATED. MAINTENANCE ADJUSTED PAX DOOR HANDLE MICROSWITCH. TEST OF SYSTEM REVEALED NORMAL OPERATION. (W)
Back to N343TE, cancelled Jan 17, 2019