N351JB, cancelled Mar 16, 2026

Service difficulty reports · 17

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N351JB' AND deregistration_id = 'N351JB-2026-03-16'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR YENA202201201038Fmu · failedFLT # 716,BUF-BOS.(EMERGENCY DECLARED). DURING CLIMB AT APPROX 12000FT ENGINE 1 BEGAN SURGING BETWEEN 56% - 79% N1 . UPON LEVEL OFF AT 19,000 FEET, THE SURGE STOPPED. ONCE WE BEGAN DECENT IT SURGED ONE MORE TIME, THEN WAS NORMAL THROUGHOUT LANDING ROLL.; SEE Jan 18, 2022 · N351JB · Emb ERJ190100IGW · Fuel Controlling SystemSDR YENA2022010400005Heat Exchanger · leakingFLT 468, FLL-ATL (AIR TURN BACK TO FLL). BLEED 1 LEAK ON EICAS AFTER TAKEOFF AT ABOUT 13K FT ; ACCOMPLISHED FIM TASK 36-21-00-810-813-A FOUND DC4 GREASE (INCREASES CAPACITANCE CHANGES IMPEDANCE) ON LOOP3 L/H PACK CERAMIC PINS CHA & B . CLEANED & REPLACED CERADec 26, 2021 · N351JB · Emb ERJ190100IGW · Pneumatic Distribution SystemSDR YENA2020061700364Pin · misinstalledDURING HEAVY MAINTENANCE, SAFETY PIN CANNOT BE FULLY INSERTED IN THE SLIDE ON R1 DOOR. PERFORMED CONTROLLED SLIDE DEPLOYMENT OF DERVICE DOOR 821 PER MAD 25-03-12-006A IAW GMM PROCEDURE 6.25. REMOVED AND REPLACED EMERGENCY EVACUATION ESCAPE SLIDE FWD SERVICE Jun 10, 2020 · N351JB · Emb ERJ190100IGW · Escape SlideSDR YENA2020012140021Seal · leakingFT # 490, MCO-JFK. RETURNED TO FIELD. BLEED 1 LEAK MSG CLIMBING THROUGH 17,000 FT. BLEED 2 WAS ALREADY ON MEL; FOUND # 1 ENG PRECOOLER OUTLET SEAL LEAKING SEE LG PAGE 2739138 ITEM # 1 FOR CORRECTIVE ACTION. REMOVED #1 ENG PRECOOLER OUTLET & SKIRT AND PRECOOLERJan 14, 2020 · N351JB · Emb ERJ190100IGW · Pneumatic Distribution SystemSDR YENA201708240691Strut · leakingDECLARED EMERGENCY. DUIRNG CLIMB OUT, LG WOW SYS FAIL MESSAGE ON EICAS. COMPLIED W/QRH. ALL COMPONENTS FUNCTIONED NORMALLY ON LANDING ROLLOUT; FOUND NLG LEAKING FLUID FROM LOWER SLIDING TUBE. STRUT EFLATED. NLG SPARE SEAL ACTIVATED IAW AMM 32-21-02. SERVICED NAug 24, 2017 · N351JB · Emb ERJ190100IGW · Nose/Tail Landing GearSDR YENA20160822747Seal · failedSHORTLY AFTER TAKEOFF, AFTER GEAR RETRACTION, CREW RECEIVED A LG WOW SYS FAIL EICAS MESSAGE. EMERGENCY DECLARED, DECISION WAS MADE TO RETURN TO DEPARTURE. ACFT LANDED UNEVENTFULLY. AFTER TROUBLESHOOTING FOUND THAT THE NLG STRUT SEAL FAILED. R & R NLG STRUT SAug 22, 2016 · N351JB · Emb ERJ190100IGW · Nose/Tail Landing Gear Strut/AxleSDR YENA20160203105Floorbeam · corrodedFLOORBEAM CORROSION FRAME 17 FROM RBL 17.0 -42.0"; CROSSBEAM REPAIR IAW E16-056-01.Feb 3, 2016 · N351JB · Emb ERJ190100IGW · Fuselage Main, Floor BeamSDR YENA20160203104Floorbeam · corrodedFLOORBEAM FRAME 17 CORROSION FROM RBL17.0-42.0"; REPAIR CROSSBEAM IAW E16-056-01.Feb 3, 2016 · N351JB · Emb ERJ190100IGW · Fuselage Main, Floor BeamSDR YENA20160203103Floorbeam · corrodedFLOORBEAM FRAME 17 CORROSION FROM RBL 17.0 -42.0"; REPAIR CROSSBEAM IAW E16-056-01.Feb 3, 2016 · N351JB · Emb ERJ190100IGW · Fuselage Main, Floor BeamSDR YENA20160203102Floorbeam · corrodedFLOORBEAM FRAME 17 CORROSION FROM RBL 17.0-42.0"; REPAIR CROSSBEAM IAW E16-056-01.Feb 3, 2016 · N351JB · Emb ERJ190100IGW · Fuselage Main, Floor BeamSDR YENA20160203101Floorbeam · corrodedFLOORBEAM AT FRAME 17 CORROSION FROM RBL 17.0-42.0"; REPAIRED IAW E16-056-01.Feb 3, 2016 · N351JB · Emb ERJ190100IGW · Fuselage Main, Floor BeamSDR YENA20160203100Floorbeam · corrodedFLOORBEAM AT FRAME 17 CORROSION FROM RBL 17.0-42.0"; REPAIR FLOORBEAM IAW E16-056-01.Feb 3, 2016 · N351JB · Emb ERJ190100IGW · Fuselage Main, Floor BeamSDR YENA20160203099Floorbeam · corrodedFLOORBEAM CORROSION FRAME 14, RBL 31-31.75"; FLOORBEAM REPAIR IAW E16-064-01.Feb 3, 2016 · N351JB · Emb ERJ190100IGW · Fuselage Main, Floor BeamSDR YENA20160203098Floorbeam · corrodedFLOORBEAM CORROSION FRAME 14, RBL 13.5-13.75"; REPAIR FLOORBEAM IAW E16-064-01.Feb 3, 2016 · N351JB · Emb ERJ190100IGW · Fuselage Main, Floor BeamSDR YENA20160203097Seat Track · corrodedRIGHT SEAT TRACK CORRODED FROM 4" AFT FRAME 13 TO 4" AFT FRAME 17, RBL 12.5"; R & R NEW SEAT TRACK IAW SRM 51-41-01, 53-10-10, FIG 56A, ITEM 270.Feb 3, 2016 · N351JB · Emb ERJ190100IGW · Fuselage, Seat/Cargo Attach FittingsSDR YENA20131228250Sensor · failedCREW DECLARED AN EMERGENCY, EICAS SLAT FAIL MESSAGE LEVELING AT CRUISE 340. PERFORMED FIM TASK 27-83-00-810-814-A, R & R OTBD SLAT SKEW SENSOR AT SLAT PANELS 2/3 IAW AMM 27-83-01. OPS CHECK NORMAL.Dec 28, 2013 · N351JB · Emb ERJ190100IGW · Leading Edge Slat Position Indicating SystemSDR YENA20130303054I/O Module · failedFLT 1731 JFK-BDA, AIR RETURN TO JFK DUE TO HF INOP. HF RADIO VERY GARBLED AND UNREADABLE TRANSMIT FUNCTIONS. READABLE ON THE OTHER END (HIGH FREQUENCY (HF) COMMUNICATION SYS). REMOVED AND REPLACED CONTROL I/O MODULE IN MAU NR 1 CARD 6 IAW AMM 31-41-05. PERMar 3, 2013 · N351JB · Emb ERJ190100IGW · HF Communications System
Back to N351JB, cancelled Mar 16, 2026