N361PH, cancelled Jan 11, 2021
Service difficulty reports · 237
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N361PH' AND deregistration_id = 'N361PH-2021-01-11' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N361PH' AND deregistration_id = 'N361PH-2021-01-11' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR A8ZR20180921003Light · defectiveRT FWD EMERGENCY EXIT DOOR, LT & RT UNDER WING EMERGENCY EXIT DOOR BETA LIGHTS P/N 1971001 FAILED BRIGHTNESS CHECK REF TASK CARD 3350/02 AND REPLACED REF AMM 33-51-00 REV 38.SDR JJBA20180102002Battery Pack · inoperativeCENTER AISLE EMERGENCY OVERHEAD LIGHT INOPERATIVE. R & R THE BATTERIES AT POSITION 1 & 2 IAW AMM 33-51-00, OPS CHECKED GOOD.SDR JJBA20171030002O-Ring · not reportedNR 1 ENG OIL PRESS LOW ENG SHUT DOWN IN FLT. R&R NR 1 ENGINE A/C GEN O-RINGS. PERFORMED ENGINE RUNS.SDR JJBA20170517029Bellcrank · defectiveNLG DOOR AMBER LIGHT ILLUMINATED DOOR HALF OPEN. ALL 3 GREEN DOWN AND LOCKED LIGHTS ILLUMINATED. REPLACED NLG DOOR BELL CRANK ASSY. OPS CHECK SAT.SDR JJBA20170506022Door Sill · corrodedCORROSION FOUND AROUND DRAIN LOCATED UNDER PASSENGER DOOR SILL. CORROSION BLENDED IAW SRM 51-20-11.SDR JJBA20170505021Threshold · corrodedCORROSION FOUND ON LOWER SILL OF PASSENGER DOOR FRAME. REPLACED DOOR THRESHOLD. SRM 51-10-00.SDR JJBA20170505007Skin · crackedCRACK FOUND INSIDE AIR STAIR DOOR SKIN AT LOWER FWD ATTACHMENT POINT. REPAIRED.SDR JJBA20170505006Skin · corrodedCORROSION FOUND ON FWD AND AFT SKIN TO EDGE BEAM ANGLE. CORROSION REMOVED AND REPAIRED IAW SRM 51-20-16SDR JJBA20170504005Skin · dentedLARGE SCRATCH AND DENT NEAR BOTTOM OF CARGO DOOR REPAIR. REPAIRED THE SKIN ASSEMBLY IAW RD 8-52-230.SDR JJBA20170503018Frame · crackedCRACK FOUND ON THE FRAME WHERE PANEL 262AT ATTACHES. REPAIRED IAW SRM 51-42-05.SDR JJBA20170503014Skin · gougedTWO SMALL GOUGES AT BS 557.5, STRINGERS 23 - 24L. REPAIRED IAW 51-13-01 AND SRM 53-00-16. RD 8-53-15198.SDR JJBA20170502019Fairing · puncturedRIGHT FWD WING TO FUSELAGE FAIRING PUNCTURED. REPAIRED IAW SRM 51-70-00, 53-70-28, 51-20-26, AND 51-20-36.SDR JJBA20170502017Structure · dentedSMALL DENT BS 564, STRINGERS 27-28S. RAISED/REPAIRED.SDR JJBA20170502011Structure · gougedSMALL GOUGE AT BS 204.5, STRINGERS 28 - 29R. REPAIRED IAW 51-13-01, AND 53-00-16.SDR JJBA20170501016Structure · gougedGOUGE AT BS 555.5 STR 27-28P. RAISED/REPAIRED.SDR JJBA20170501015Structure · dentedTWO SMALL DENTS ADJACENT TO EACH OTHER JUST OFF OF STRINGER 29P, BS 559.5. RAISED/REPAIRED.SDR JJBA20170501012Structure · gougedSMALL GOUGE AT BS 218.50, STRINGERS 28 - 29R. REPAIRED IAW 51-13-01, AND 53-00-16.SDR JJBA20170501008Fairing · delaminatedDELAMINATION OF THE EXTERNAL PLIES OF THE NACELLE TAIL FAIRING. REPAIRED PER RD 8-54-1917.SDR JJBA20170301004Proximity Sensor · defectiveNOSE GEAR GREEN DOWN AND LOCK ON LANDING GEAR PANEL INTERMITTENT. R & R PROX SENSOR. PERFORMED GEAR SWINGS SEVERAL TIMES IAW AMM 32-30-00. OPS CHECK SAT NO FAULT DETECTED.SDR JJBA20160706002Selector · inoperativeSMOKE IN THE COCKPIT FROM MLG PANEL. R & R THE MLG SELECTOR UNIT. OPS CHECKED SAT.SDR JJBA20160701001Unknown · smokeSMOKE IN THE COCKPIT WHEN NR 2 BLEED TURNED ON AFTER START. CHECKED ACM FOR LEAKS, NONE FOUND. CHECKED ACM OIL LEVEL. FOUND TO BE SAT. PERFORMED ENGINE RUNS WITH BLEEDS ON. NO SMOKE OR FUMES NOTED.SDR JJBA20160505002Stop · defectiveUNABLE TO OPEN MAIN CABIN DOOR. R & R MAIN CABIN DOOR HANDLE STOP.SDR JJBA20160120009Battery · dischargedEMERGENCY LIGHTING WILL NOT ILLUMINATE. R & R EMER LIGHT BATTERIES.SDR JJBA20150920005Battery · dischargedFLIGHT ATTENDANT EMER LIGHTS WILL NOT TEST. R & R 6 EACH EMER LIGHT BATTERIES, PS 1 - PS 6.SDR JJBA20150713004Battery · dischargedOVERHEAD EMER LIGHT AT ROW 4 INOPERATIVE. R & R BATTERIES & POWER SUPPLY PS2.SDR JJBA20150713003Battery · dischargedEMERGENCY LIGHT OVER MAIN CABIN DOOR INOPERATIVE. R & R BATTERIES & POWER SUPPLY PS2.SDR JJBA20150713002Battery · dischargedOVERHEAD EMER LIGHTS ABOVE GALLEY INOPERATIVE. R & R ALL EMER BATTERIES & POWER SUPPLIES PS2.SDR JJBA20140330001Unknown · unknownAT 10,000 FEET, AIRSPEED 215 KTS VIOLENTLY DIVED WITH AUTO PILOT ENGAGED. VIBRATION DECREASED AS AIRSPEED DECREASED. FOUND DAMAGE 325AL & 325. R & R PANELS, DVI HORIZONTAL & VERTICAL STAB, NO DAMAGE FOUND.SDR JJBA20140314007Light · missingRED STRIP MISSING FROM FLOOR LIGHTING PROXIMITY EMERGENCY ESCAPE PATH MARKING SYS ROW 1. R & R RED STRIP.SDR JJBA20140123012Light · inoperativeSEVERAL EMERGENCY LIGHTS INOPERABLE. R & R PS & PS3.SDR JJBA20131104003Connector · unsecureSMOKE WARNING LIGHT FLICKED ON AND OFF IN FLIGHT. TIGHTENED CONNECTOR, SAFETIED AND PERFORMED OPS CHECK.SDR JJBA20130624032Battery Pack · inoperativeDURING PREFLIGHT, THE CREW REPORTED THAT ONE RED FLOOR EMERGENCY WAS INOP. MX REPLACED THE ASSOCIATED BATTERY AND ALL OPS CHECKS WERE SATISFACTORY.SDR JJBA20130622031Battery Pack · inoperativeDURING PREFLIGHT, IT WAS REPORTED THE EMERGENCY EXIT SIGN ABOVE THE MAIN CABIN DOOR WAS NOT ILLUMINATING DURING TESTING. MX R & R THE BATTERY FOR THE SIGN. ALL OPS CHECKS WERE SATISFACTORY.SDR JJBA20130421010Battery · dischargedCREW REPORTED THAT THE EMERGENCY LIGHTS WERE INOPERATIVE WHEN THEY ARRIVED AT THE ACFT. THEY ALSO FOUND THE EMERGENCY LIGHT SWITCH IN THE ON POSITION. MX CREW REPLACED ALL 6 OF THE EMERGENCY LIGHT BATTERIES.SDR JJBA20130203003Switch · dirtyCREW REPORTED THAT THE MASTER CAUTION FLASHER WOULD NOT CANCEL. GROUND MX CREW CLEANED THE CONTACT SWITCH. ALL OPS CHECKED PRODUCED SATISFACTORY RESULTS.SDR JJBA20130130019Sensor · inoperativeDURING CRUISE FLIGHT, CREW REPORTED THAT THE NR 1 ENGINE OIL TEMP WAS HIGH. GROUND MX R & R THE OIL TEMP SENSOR. ALL OPS CHECKS WERE SATISFACTORY.SDR JJBA20121226008Battery Pack · inoperativeMX CREWS OBSERVED MULTIPLE CABIN EMERGENCY LIGHTS NOT ILLUMINATING DURING A ROUTINE TEST. THE EMERGENCY LIGHT BATTERIES WERE R & R AND ALL OPS CHECKS WERE SATISFACTORY.SDR JJBA20120428010Power Supply · failedEMERGENCY EXIT SIGN FAILED TO ILLUMINATE DURING A TEST. GROUND MX CREW R & R THE PS2 BATTERY POWER SUPPLY UNIT. AN OPS CHECK PRODUCED SATISFACTORY RESULTS AND THE ACFT WAS RETURNED TO SERVICE.SDR JJBA20120428009Power Supply · failedEMERGENCY EXIT SIGN FAILED TO ILLUMINATE DURING A TEST. GROUND MX CREW R & R THE PS2 BATTERY POWER SUPPLY. AN OPS CHECK PRODUCED SATISFACTORY RESULTS AND THE ACFT WAS RETURNED TO SERVICE.SDR JJBA2012012900001Battery Pack · dischargedDURING PRE-FLIGHT INSP, AIRCREW FOUND THAT THE EMERGENCY LIGHTS WOULD NOT TEST. AIRCREW PLACED THE EMERGENCY LIGHT SWITCH IN THE "ARM" POSITION AND ALLOWED THE EMERGENCY LIGHT BATTERY PACKS TO CHARGE. THEY PERFORMED AN OPS CHECK AND SYS CHECKED SATISFACTORY.SDR JJBA20111025361PHBattery · dischargedFLIGHT CREW REPORTED ON LOG PAGE 1604 THAT THE EMERGENCY CEILING LIGHTS WERE INOPERATIVE. MX CONTROL INFORMED THEM TO GROUND RUN THE ACFT FOR 30 MINUTES TO CHARGE THE BATTERIES PERFORMED, OPS CHECK SATISFACTORY.SDR JJBA201110100001Bulb · inoperativeFLIGHT CREW REPORTED THAT THE EMERGENCY LIGHTS NEAR ROW 9 CEILING ARE NOT WORKING. MX R & R THE LIGHT BULBS PERFORMED, OPS CHECKED SATISFACTORY.SDR JJBA20110917001BBulb · inoperativeFLIGHT CREW REPORTED EMERGENCY CREW REPORTED CEILING LIGHTS ARE NOT WORKING. MX REPLACED BULB, PERFORMED OPS CHECK SATISFACTORY.SDR JJBA361PH331516Light · malfunctionedFLIGHT CREW REPORTED EMERGENCY LIGHT FORWARD FLOOR STRIP LIGHT NOT WORKING. MX CREW TESTED EMERGENCY LIGHT AND COULD NOT DUPLICATE. PERFORMED OPS CHECK WAS SATISFACTORY.SDR JJBA361PH331515Light · malfunctionedFLIGHT CREW REPORTED EMERGENCY LIGHT STRIP NOT WORKING. MX COULD NOT DUPLICATE, OPS CHECK WAS SATISFACTORY.SDR JJBA361PH331499Bulb · unsecureFLIGHT CREW REPORTED CEILING EMERGENCY LIGHT NOT WORKING AT ROW 9. MX CREW RESEATED BULB IN THE LIGHT SOCKET. OPS CHECK WAS SATISFACTORY.SDR JJBA361PH331462Battery Pack · inoperativeFLIGHT CREW REPORTED EMERGENCY LIGHT AT RT UNDER WING EXIT AND IN THE CEILING AT ROW 9 ARE NOT WORKING. MX CREW R & R BATTERIES PS4 AND PS5. PERFORMED OPS CHECK, OPS CHECK WAS SATISFACTORY.SDR JJBA201027055Potentiometer · shortedON T/O CLIMB OUT ACFT HAD AN UNCOMMANDED ROLL. TRIM SWITCH UNRESPONSIVE, PERFORMED UNCOMMANDED ROLL CHECKLIST, NO OTHER ACTION TAKEN. MX FOUND THAT THE AILERON TRIM POTENTIOMETER WAS SHORTED. REPLACED POTENTIOMETER. OPS CHECK SATISFACTORY.SDR JJBA201033917Light · inoperativeDURING PRE-FLIGHT FORWARD RIGHT RED EMERGENCY FLOOR LIGHTS DID NOT COME ON. REMOVED AND REPLACED LIGHT STRIP. OPS CHECK SATISFACTORY.SDR JJBA201025817Battery Pack · shortedDURING PRE-FLIGHT TRIED TO TEST EMERGENCY LIGHTS, THEY DID NOT COME ON. RECHARGED SYS IAW MX CONTROL. SYS CHECKED SATISFACTORY.