N402FE, cancelled Jan 25, 2016
Service difficulty reports · 181
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N402FE' AND deregistration_id = 'N402FE-2016-01-25' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N402FE' AND deregistration_id = 'N402FE-2016-01-25' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201006192070Stringer · corrodedAFT CARGO BILGE AREA FR 54 LAST 9 INCHES STR 46 L HAS APPROX 3 SQ IN OF CORROSION. REMOVED CORROSION ON STR 46L AT FR 54 IAW SRM 51-74-10 CHECKED. FOUND OUT OF LIMITS IAW SRM 53-10-14. REPAIRED STR 46L IAW SRM 53-10-14 PAGE 203 AND 204, FIG 201, STRINGER.SDR FDEA201006192069Seat Track · corrodedMDCC SEAT TRACK 2 R FR 54 HAS A 1 SQ IN AREA OF CORROSION. REMOVED CORROSION IAW SRM 51-74-10 CHECKED AND FOUND OUT OF LIMITS IAW SRM 53-10-16 FIG 101. R & R MDCC SEAT TRACK 2R IAW SRM 51-72-10.SDR FDEA201006192068Adapter · corrodedINTERCOSTAL TRACK AT FRAME 47/48 BETWEEN LT SEAT TRACKS 2 AND 3 HAS CORROSION INSIDE THE SCALLOPS APPROX .5 SQ IN. REMOVED CORROSION IAW SRM 51-74-10. CHECK LIMITS FOUND OUT OF LIMITS IAW SRM 53-10-15 . R & R ADAPTOR IAW SRM 51-40-21.SDR FDEA201006192067Floor Support · corrodedINTERCOSTAL TRACK AT FR 47/48BETWEEN RT NR 2 AND NR 3 SEAT TRACKS HAS CORROSION INSIDE THE SCALLOPS APPROX 1 SQ INCH. REMOVED CORROSION IAW SRM 51-74-10 PAGE 205 , CHECKED FOUND OUT OF LIMITS IAW SRM 53-10-15, FIG 101 . R & R CROSSBEAM IAW SRM 51-75-10, PAGE SDR FDEA201006192066Floor Support · corrodedMAIN DECK CARGO INTERCOSTAL TRACK AT FR 54 BETWEEN RT SEAT TRACKS 2 AND 3 HAS CORROSION INSIDE THE SCALLOPS APPROX 1 SQ IN. REMOVED CORROSION IAW SRM 51-74-10 FOUND OUT OF LIMITS IAW SRM 53-10-15. R & R INTERCOSTAL TRACK AT FR 54 BETWEEN SEAT TRACKS 2 AND 3SDR FDEA201006192065Seat Track · corrodedCABIN SEAT TRACK 4L FROM FR 50 TO FR51 HAS APPROX. 8 SQ IN OF CORROSION. REMOVED CORROSION IAW SRM 51-74-10 P205. CHECKED FOUND OUT OF LIMITS IAW SRM 53-10-16 FIG 201. REPAIRED SEAT TRACK 4L IAW SRM 53-10-16, FIG 203.SDR FDEA201006182053Stringer · corrodedAFT CARGO COMPARTMENT BILGE STRINGER 46LT HAS CORROSION AT FRAME 54.3 PLUS 13 IN. REMOVED CORROSION IAW SRM 51-74-10, CHECKED AREA FOUND TO BE OUT OF LIMITS IAW SRM 53-10-00 . REPAIRED STRINGER 46 LT IAW SRM 53-10-14, FIG 201.SDR FDEA201006182052Floorbeam · corrodedFWD CARGO COMPARTMENT FLOORBEAM HAS 3X1 INCH CORROSION UNDER NR 1L CARGO LOADING ROLLER TRACK AT FR 33. REMOVED CORROSION AND CHECKED MATERIAL LOSS FOUND 100 PERCENT LOSS. REPAIRED FLOORBEAM IAW SRM 53-10-15, PAGE 237.SDR FDEA201006182050Seat Track · corrodedCORROSION AT MDCC SEAT TRACK 4L BETWEEN FR 54.3 AND FR 58 , DEFECT MEASURES 4 SQ INCHES OF CORROSION. REMOVED CORROSION IAW SRM 51-74-10 PAGE 205 , CHECKED FOUND TO BE OUT OF LIMITS IAW SRM 53-10-16, FIG 101 . R & R SEAT TRACK 4L BETWEEN FR 54.3 AND FR 58 IASDR FDEA201006061846Seat Track · corrodedSEAT TRACK 3R BETWEEN FRAMES 53 AND 54 HAS 4 SQ INCHES OF CORROSION IN AND AROUND SCALLOPS. REMOVED CORROSION IAW SRM 51-74-10. CHECKED LIMIT, FOUND OUT OF LIMITS IAW SRM 53-10-16. R & R SEAT TRACK SECTION AND REPAIRED IAW SRM 53-10-16 PARA 7, PAGES 227-232, SDR FDEA201006061845Seat Track · corrodedSEAT TRACK 4 R BETWEEN FRAMES 74 AND 80/82 HAS 5 EA AREAS OF COROSION, DEFECTS MEASURE 5 SQ IN REMOVED COROSION IAW SRM 51-74-10, PAGE 5. CHECKED AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-16, FIG 101. CUT OUT DAMAGED SECTION AND REPAIRED IAW SRM 53-10-16SDR FDEA201005251630Seat Track · corrodedMDCC, SEAT TRACK 3R, HAS 3 SQ. INCHES OF CORROSION AT FR 15B REMOVED CORROSION IAW A310 SRM 51-74-10. CHECKED LIMITS , FOUND OUT OF LIMITS IAW SRM 53-10-16 FIG 101. R & R SEAT TRACK 3R BETWEEN FR 15A TO FR 19 IAW SRM 53-10-16 AND SRM 51-72-10.SDR FDEA201005251629Seat Track · corrodedSEAT TRACK 3L, BETWEEN FRAMES 14C & 15B, HAS 2 SQ. INCHES WITH EXFOLIATION CORROSION CHECKED MATERIAL LOSS IAW SRM 53-10-16 FIG 101 AND FOUND TO BE OUT OF LIMITS. R & R SEAT TRACK IAW SRM 53-10-16.SDR FDEA200901160216Outflow Valve · inoperativeON TAXI OUT RECEIVED OVERBOARD EXTRACT VALVE FAULT. FOLLOWED MEL BUT WOULD NOT MAINTAIN PRESSURIZATION IN FLIGHT. DIVERT TO ATL PER GOC. ACN RELEASED FOR SERVICE PER MEL/CDL: 21-23-06 CATEGORY: C. VENT OVBD VALVE INOP, VALVE MANUALLY SET PARTIALLY OPEN, FSDR 07FDEA05061Switch · misalignedFWD CARGO DOOR UNLOCK WARNING AND ECAM MESSAGE AT 18,000' AND PSID 7.0, SPEED 340 KTS. PREECEDING THE CARGO DOOR UNLOCK WARNING BY LESS THAN 1" WAS A LOUD "THINK" FROM UNDERSIDE OF AIRCRAFT. SLOWED TO 240 KTS, NO CHANGE. DEPRESSURIZED AND DESCENDED AND PSIDSDR 07FDEA04993Skin · misrepairedLEFT WING EXTERNAL REPAIR DOUBLER ON TRAILING EDGE END RIB, APPROXIMATE WING STATION 1278 BETWEEN WING RIBS 20 AND 21 REAR SPAR REQUIRES EVALUATION FOR MAJOR/MINOR DETERMINATION AND IF REPAIR WAS ACCOMPLISHED USING FAA APPROVED DATA. EVALUATED REPAIR, FOUND SDR 07FDEA04999Fitting · gougedFWD CARGO COMPARTMENT DOOR LOCK FITTING AT NR 1 POS GOUGED ON BOTH LUGS. RECEIVED NEW DOOR LOCK FITTING P/N A5377293500200 PO NR 597399.1. INSTALLED FITTING IAW A310-200 SRM 51-40 20 AND 53-13-83 PARA 5 SHT 1. FITTING WAS INSTALLED ON FEDEX JOB CARD NON-ROUSDR 07FDEA04998Sill · corrodedFWD CARGO COMPARTMENT DOOR SILL LOWER/AFT CORNER CORRODED. REMOVED NR 10 LATCH FITTING AND ANGLE IN AFT CORNER. REMOVED CORROSION IAW A310-200 SRM 51-74-10-8. MAT THICKNESS .243 LOWEST SPOT REMOVED 0.110 FOUND TO BE OUT OF LIMITS. FABRICATED REPAIR IAW ASDR 07FDEA04995Floorbeam · corrodedAT FRAME 26 FLOOR SUPPORT T-CAP HAS CORROSION AT RBL 59. CUT DAMAGE IAW A310 SRM 53-10-15. MATERIAL ID LN 9497-420 AND LN 9496-310 IAW A310 SRM 53-10-15. FABRICATED REPAIR PARTS IAW A310 SRM 53-10-15, ALODINED AND PRIMED IAW A310 SRM 51-21-10. PAINTED IAW SDR 07FDEA04994Support Angle · corrodedAT FRAME 26 SUPPORT ANGLE UNDERNEATH T-CAP AT RBL59 HAS CORROSION. REMOVED GUIDE AND FITTING IAW A310 SRM 51-40-02 PG 7. RECIEVED NEW FITTING P/N A5377364420100. DRILLED AND LOCATED FITTING IAW A310 SRM 51-40-44 PG 16 AND INSTALLED FITTING AND GUIDE IAW A3SDR 07FDEA04969Fitting · corrodedFWD CARGO COMPARTMENT DOOR LOCK FITTING AT NR 1 POSITION CORRODED. REMOVED AND REPLACED FWD CARGO COMPARTMENT DOOR NR 1 LOCK FITTING IAW A310-200 SRM 51-40-20.SDR 07FDEA04945Crossbeam · damagedFWD E/E BAY FRAME 14 RT CROSS MEMBER VERTICAL LEG HOLE LABELED "A" DAMAGED. THIS SDR WAS GENERATED TO REPLACE SDR 07-4770. THIS SDR IS TO MAKE CORRECTIONS IN THE FOLLOWING BLOCKS 5A, 5C, 5D, 5F.SDR 07FDEA04923Stringer · corrodedCORROSION ON STRINGER 56R FROM FRAME 60 TO 61 ALSO ON FRAME SHEAR TIE IN AFT PIT. REMOVED SHEAR TIE IAW A310-200 SRM 53-10-14 PARA. 4.A (2) (A) AND DAMAGE STRINGER AT FRAME 60-61 S56R IAW A310-200SRM 53-10-14 PARA. 4.A (2) (A). REMOVED CORROSION IN SHEAR TIESDR 07FDEA04863Beam · crackedNR 3 HOLE ON FIGURE 8, AREA ON RT PAX DOOR INDICATED AS CRACKED WHEN CHECKED BY BHEC IAW NDT MANUAL 53-30-53 USING MACHINE T8209A. REAMED HOLE IN REF TO SRM 51-40-51. PERFORMED BHEC IAW NTM 53-30-53-NO CRACKS FOUND. FABRICATED REPAIR BUSHING, PRIMED, PAINTESDR 07FDEA04797Bulkhead · corrodedFWD PIT, 3 INCHES AFT FRAME 39 LEFT, 3 INCHES ABOVE STRINGER 30 LEFT, HORIZONTAL BULKHEAD LT FWD CORNER, SEVERE EXFOLIATION CORROSION. COMPLIED WITH EA 6-5310-109221SDR 07FDEA04795Frame · crackedFRAME 47 FASTENER HOLE INSPECTION, NR 4 RT HOLE HAS INDICATION OF DEFECT. REAMED HOLE TO TRANSITION FITTING IAW FED EX A310-200 SRM 51-40-40 PG14. INSTALLED FASTENER IAW A310-200 SRM 51-40-21 PG 24. BHEC NR 4 HOLE REF EA 6-5710-112994. NO CRACK INDICATION NSDR 07FDEA04776Adapter · crackedMAIN CABIN FR 46 RT SIDE, ADAPTER CRACKED (OVER WING BOX) BS 2553 RBL 60. REMOVED AND REPLACED SEAT TRACK ADAPTER IAW SRM 51-40-21 PG7.SDR 07FDEA04778Trunnion · crackedRT MLG TRUNNION RIB 5 FWD LUG AFT FACE APPEARS TO BE CRACKED. SPOT FACE AND CHAMFERED ON E.O. 6-5710-7-5010 PT8 - NO CRACKS FOUND.SDR 07FDEA04770Frame · damagedFWD E/E BAY FRAME 14 RT VERTICAL LEG HOLE LABELED "A" DAMAGED FABRICATED AND INSTALLED 2. REPAIR BUSHINGS IAW FED EX EA 6-5310-109224 "FUSELAGE-MAINFRAME-O.S. HOLES IN NLG WHEEL WELL CROSSMEMBER-REPAIR" BY TIMCO EMP NR 110294/QC254.SDR 07FDEA04760Skin · misrepairedAGING AIRCRAFT DETERMINATION OF EXTERNAL DOUBLER ON FUSELAGE SKIN AT FRAME 40 STRINGER 16 TO 18 RT REQUIRE EVALUATION FOR MAJOR/MINOR DETERMINATION AND IF THE REPAIR WAS ACCOMPLISHED USING FAA APPROVED DATA. EVALUATED REPAIR FOUND NOT TO BE WITHIN SRM REQUIRESDR 07FDEA04759Frame · gougedMAIN CABIN FR55 AT APPROX L15L HAS A PUNCTURE IN FLANGE OF FRAME. CUTOUT DAMAGE AND REPAIRED WITH REINFORCING PLATE/REPAIR DOUBLER IAW A310 SRM 53-10-13 PAGE 206-209 FIGURE 202.SDR 07FDEA04706Floorbeam · corrodedBULK PIT BELOW FLOOR, CORROSION ON FLOOR FRAME 67 UNDER NUTPLATE AT RBL 38. REMOVED CORROSION IAW A310 SRM 51-22-00 PG 11, CHECKED LIMITS, ORIG MAT 0.130, MAT. REMOVED .040, MAT REMAINING .090. FOUND OUT OF LIMITS IAW A310 SRM 53-10-15 PG 101 UTG NR 8225-B.SDR 07FDEA04693Arm · corrodedNR 5 RUDDER HINGE ARM (3EA) BEARINGS WORN, CORROSION ON LUG FACE REMOVED CORROSION FROM LUG FACE IAW A310-200 MM 51-24-10-8 LUG THICKNESS OUT OF LIMITS IAW A310-200 SRM 55-30-00. ORDERED AND RECEIVED SERVICEABLE NR 5 HINGE ARM S/N776235. HINGE ARM WAS INSTALSDR 07FDEA04687Floor Support · corrodedINTERGRANULAR CORROSION ON TOP OF MAIN CABIN FLOORBEAM AND AROUND FLOOR PANEL HOLES, LONGITUDINAL FLOORBEAM UNDER LT FWD LAV MARKED. REMOVED CORROSION IAW A310 SRM 51-74-10. ORIGINAL THICKNESS .079, REMOVED .040, .039 REMAINING. MATERIAL LOSS BEYOND ALLOWABSDR 07FDEA04663Floorbeam · corrodedMAIN CABIN FLOORBEAM STRUCTURE BENEATH LT FWD LAV BETWEEN FR 14 AND 14B HAS INTERGRANULAR CORROSION. REMOVED CORROSION IAW A310 SRM 51-74-10. ORIGINAL THICKNESS .079. REMOVED .045. REMAINING MATERIAL NOT WITHIN ALLOWABLE LIMITS IAW A310 SRM 53-10-00. UT GASDR 07FDEA04658Fitting · crackedLEFT SIDE CRACK INDICATION IN FR 43A LOWER HOLE APPROX 12 O'CLOCK IN FRAME FITTING ONLY REMOVED LOWER FRAME FITTING AT FR 43A THAT IS CRACKED. INSTALLED NEW FITTING IAW A310 51-40-40, 51-40-21 PG 24.SDR 07FDEA04656Fitting · crackedRIGHT SIDE CRACK INDICATION IN FR43A LOWER HOLE AT APPROX 12 O'CLOCK AND 6 O'CLOCK IN FRAME FITTING ONLY REMOVED LOWER FRAME FITTING AT FR 43A, THAT IS CRACKED. INSTALLED NEW FITTING IAW A31 SRM 51-40-21 PG 24 AND 51-40-40 PG 17.SDR 07FDEA04643Attach Fitting · crackedMAIN CABIN FR45 RT SIDE ADAPTER CRACKED OVER WING BOX REPLACED FR45 ADAPTER IAW SRM 51-40-21 P7 AND AMM 20-21-12.SDR 07FDEA04645Attach Fitting · crackedMAIN CABIN FS 42 RT SIDE ADAPTER CRACKED OVERWING BOX REPLACED FR 42 RT SIDE ADAPTER IAW A310-200 SRM 51-40-21 P7 AND A310-200 AMM 20-21-12.SDR 07FDEA04644Adapter · crackedMAIN CABIN FR 43 RT SIDE, ADAPTER CRACKED OVERWING BOX REPLACED FR 43 RT SIDE ADAPTER IAW A310-200 SRM 51-40-21 P7 AND MA310-200 AMM 20-21-12 BY TIMCO EMP NR 5252/QC204.SDR 07FDEA04642Adapter · crackedMAIN CABIN FR44, RT SIDE, ADAPTER CRACKED OVERWING BOX REPLACED FR 44 RT SIDE ADAPTER IAW SRM 51-40-21 P7 AND A310-200 AMM 20-21-12.SDR 07FDEA04641Adapter · crackedMAIN CABIN FR 42 LT SIDE, ADAPTER CRACKED OVERWING BOX REMOVED CRACKED ADAPTER IAW SRM 51-40-21 PAR 7. INSTALLED NEW ADAPTER IAW SRM 51-40-21 AND AMM 20-21-12-0.SDR 05FDEA01916Filter · cloggedREJECTED TAKE OFF AS 95 KNOTS DUE TO ECAM WARNING 'ENG FUEL FILTER CLOG' WARNING WAS RESOLVED AS SOON AS THROTTLES WERE RETARDED. TOGA POWER WAS USED (104.7 PERCENT N1) MESSAGE DISAPPEARED QUICKLY AND WE WERE UNC ERTAIN OF WHICH ENGINE WAS AFFECTED. PULLESDR 05FDEA01477O-Ring · cutECAM ALERTED HYD RSVR LO LEVEL ON GREEN SYSTEM. ALL INDICATIONS (GAUGE, ECAM SYNOPTIC) SHOWED AND VERIFIED. QRH CONSULTED AND COMPLIED WITH MANUAL GEAR GRAVITY EXT PROCEDURES ACCOMPLISHED. TOWED TO GATE DUE NO NOSE WHEEL STEERING. T/S FOUND HYD LEAK FROM GSDR 05FDEA01155Stringer · corrodedIN ACM BAY FR 46 - FR 47 ON STR 46 L HAS AREAS OF CORROSION. REMOVED CORROSION PER A310 SRM 51-74-10 C/W EA 6-5310- 87784, FOUND ALL AREAS TO BE WITH IN LIMITS PER EA 6-5310-87784 AND A310 SRM 53-10-00. INSTALLED FASTENERS PER A310 SRM 51-40-21, RESTORED SDR 05FDEA01154Stringer · corrodedIN ACM BAY FR 39 - FR 40/41 ON STR 45 L HAS AREAS OF CORROSION. REMOVED CORROSION PER A310 SRM 51-74-10. C/W EA 6-5310-87784, FOUND ALL AREAS TO BE WITH IN LIMITS PER EA 6-5310-87784 AND A310 SRM 53-15-12 INSTALLED FASTENERS PER A310 SRM 51-40-21. RESTORED SDR 05FDEA01153Stringer · corrodedIN ACM BAY FR 46- FR 47 ON STG 51L HAS AREA OF CORROSION. REMOVED CORROSION PER A310 SRM 51-74-10 C/W EA 6-5310-87784. FOUND ALL AREAS TO BE WITHIN LIMITS PER EA 6-5310-87784 AND A310 SRM 53-10-00. INSTALLED FASTENERS PER A310 SRM 51-40-21. RESTORED SURFSDR 05FDEA01117Rib · crackedLEFT WING LOWER SURFACE T/E SKIN HAS INDICATION OF CRACK RIB 11 AT PANEL 581 AB. REPAIRED IAW EA 6-5710-87138.SDR 05FDEA01116Skin · damagedRIGHT WING BOTTOM SKIN CUTOUT FOR PANEL 650 GB HAS 1 EA ELONGATED SCREW HOLE. COMPLIED EA 6-5710-87212.SDR 05FDEA01115Rib · crackedTOP OF RIGHT WING AT RIB 20 SKIN JOINT I/B SIDE OF SPLICE HAS 4 FASTENERS SHOWING CRACK INDICATION USING NDT METHOD. REMOVED CRACKS IAW EA 6-5720--87800.