N4142N, cancelled May 2, 2003
Service difficulty reports · 20
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N4142N' AND deregistration_id = 'N4142N-2003-05-02' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N4142N' AND deregistration_id = 'N4142N-2003-05-02' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 20001102SH003Servo · inoperativeUNABLE TO ADJUST MIXTURE AND IDLE WILL NOT STAY SET. (X)SDR 20001025SH011Control Cable · frayedRIGHT AILERON CABLE FRAYED. (X)SDR 20001025SH010Control Cable · frayedFLAP SELECTOR CABLE FRAYED WHERE THE CABLE GOES AROUND THE PULLEYS AT THE FLAP SELECTOR. (X)SDR 20001017SH020Servo · failedENGINE DIED AT IDLE, UNABLE TO ADJUST MIXTURE. (X)SDR 20001017SH021Control Cable · frayedREAR TRIM CABLE FRAYED. (X)SDR 20001023SH002Tube · crackedINSPECTION OF INTAKE FOUND NR 2 INTAKE TUBE CRACKED AT THE FLANGE. (X)SDR 20001019SH021Controller · stuckTHE CONTROLLER PISTON STICK IN. A SPLIT IN POWER SETTING IN-FLIGHT AND ON THE GROUND. CONTROLLER REPLACED. (X)SDR 20001019SH016Tube · crackedINSPECTION OF INTAKE FOUND NR 2 INTAKE TUBE CRACKED AT THE FLANGE. (X)SDR 20001017SH019Controller · stuckTHE CONTROLLER PISTON STICK IN. A SPLIT IN POWER SETING IN-FLIGHT AND ON THE GROUND. CONTROLLER REPLACED. (X)SDR 20000911SH033Servo · faultyENGINE RUNNING RICH AND BLOWING BLACK SMOKE. UNABLE TO ADJUST MIXTURE. REMOVED AND SENT BACK TO TCM. (X)SDR 20000925SH039Tube · crackedTHE PILOT REPORTED THE RIGHT ENGINE RUNNING ROUGH AND VIBRATION. THE ENGINE WAS SHUT DOWN AND A SAFE LANDING WAS MADE. AIRCRAFT WAS TAKEN TO MAINTENANCE AND INSPECTION WAS DONE ON THE ENGINE, NR 4 INTAKE TUBE WAS FOUND CRACKED AT THE FLANGE OF TUBE WHERE IT SDR 20000809SH025Control Cable · frayedRIGHT AILERON BALANCE CABLE FRAYED AT WING ROOT PULLEY. (X)SDR 20000809SH015Control Cable · frayedLOWER AFT STABILATOR DOWN CONTROL CABLE FRAYED LOCATED AT STA 222.43. (X)SDR 20000622SH027Servo · failedLEFT ENGINE DIED ON ROLL-OUT AFTER LANDING. THIS SERVO HAS 923 HOURS TT SINCE NEW AND 450 HOURS FROM REPAIR OF MIXTURE PLATE. ENGINE RAN ROUGH AT IDLE AND AT LOW POWER SETTINGS. THE MIXTURE WAS ON THE RICH SIDE AND UNABLE TO ADJUST MIXTURE. SERVO REMOVED ASDR 99ZZZX4457Servo · failedENGINE RAN RICH, UNABLE TO ADJUST IDLE MIXTURE. SERVO SENT TO PRECISION FOR REPAIR.SDR 99ZZZX4454Servo · failedENGIEN RAN RICH, UNABLE TO ADJUST IDLE MIXTURE. SERVO SENT TO PRECISION FOR REPAIR.SDR 99ZZZX4456Servo · failedENGINE RAN RICH, UNABLE TO ADJUST IDLE MIXTURE. SERVO SENT TO PRECISION FOR REPAIR.SDR 99ZZZX4453Servo · failedENGINE RAN RICH, UNABLE TO ADJUST IDLE MIXTURE. SERVO SENT TO PRECISION FOR REPAIR.SDR 99ZZZX4452Servo · failedENGINE RAN RICH, UNABLE TO ADJUST IDLE MIXTURE. SERVO SENT TO PRECISION FOR REPAIR.SDR 99ZZZX4455Servo · failedENGINE RAN RICH, UNABLE TO ADJUST IDLE MIXTURE. REMOVED SERVO FROM ENGINE AND INSPECTED IDLE MIXTURE PLATE FOR GALLING. PLATE WAS FOUND GALLED. SERVO SENT TO PRECISION FOR REPAIR. THIS SERVO HAS 36 HRS TT SINCE NEW. 7 HRS SINCE PRECISION REPAIRED SERVO AT