N416NV, cancelled Feb 23, 2019
Service difficulty reports · 56
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N416NV' AND deregistration_id = 'N416NV-2019-02-23' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N416NV' AND deregistration_id = 'N416NV-2019-02-23' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR WX0A201707143274Engine · unknown(EMERGENCY DECLARED) CPT SHUTDOWN #1 ENG DUE TO LARGE THROTTLE SPLIT BETWEEN ENG1 & ENG2.SDR WX0A2017013073224Transducer · faultyABORTED TAKEOFF AT 80 KNOTS DUE TO "WHEEL NOT TURNING" LIGHT. R&R NR 3 ANTISKID TRANSDUCER.SDR WX0A2016011973071Pan · crackedMID CARGO DOOR OUTER PAN HAS CRACKS EXTENDING PAST STOP DRILL HOLES. REPAIRED MID CARGO DOOR OUTER PAN IAW EA 43-2016-006 DATED 01 13 201. WORK ACCOMPLISHED ON WO 278011 M301 ITEM 230 & WO 1012400-8000.0042.SDR WX0A2015110872991Unknown · malfunctionedAT CRUISE AT FL330 FOR ABOUT 10 MINUTES, THE FIRST INDICATION OF A PROBLEM WAS HEADING COMPARATOR PROBLEM ON THE FLIGHT MODE ANNUNCIATOR. THEN THE AUTOPILOT KICKED OFF. THE CREW NOTED A HEADING DISCREPANCY BETWEEN THE CAPTAIN'S & FO'S HEADING INDICATIONS. TSDR WX0A2015101972954Battery · dischargedEMERGENCY LIGHTS OUT, ROWS 20 - 24. REPLACED BATTERIES AT SEAT ROW 24. OPERATIONS CHECKED GOOD IAW AMM 33-53-00-4.SDR WX0A2015101572942Battery · dischargedEMERGENCY LIGHTS INOPERATIVE ROW 21 - 24. REPLACED BATTERIES AT ROW 24 IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.SDR WX0A2015101272934Battery · dischargedEMERGENCY LIGHTS INOPERATIVE ROWS 21 - 24. REPLACED BATTERIES AT ROW 24 IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.SDR WX0A2015101272936Unknown · fumesFLIGHT ATTENDANTS REPORTED SMELL OF FUEL FUMES IMMEDIATELY AFTER LANDING. ACCOMPLISHED TC 21-059-002 CABIN ODOR & SMOKE TROUBLESHOOTING. SEE LOG PAGE 582709 FOR APU FUEL LEAK REPAIR. ACCOMPLISHED TC 21-059-008 ALT SERVICING AC WATER SEPARATOR & PACK BURN OUSDR WX0A2015072072738Connector · brokenEMERGENCY LIGHT EXIT SIGN FOR R1 DOOR INOPERATIVE. FOUND WIRE BROKEN AT CONNECTOR. REPAIRED CONNECTOR IAW AMM 20-50-01. OPERATIONS CHECKED GOOD IAW AMM 33-52-00.SDR WX0A2015070672719Access Panel · corrodedRIGHT WING LE ACCESS PANEL 1266C HAS CORROSION ON TE. REPAIRED LOWER WING ACCESS PANEL, RT WING, 1266C IAW SRM 57-06A.SDR WX0A2015070672716Battery · dischargedEMERGENCY EXIT LIGHT INOPERATIVE ABOVE ALL OVERWING EXITS. R & R OVERWING EXIT EMER EXIT LIGHT BATTERIES & OPERATIONS CHECKED OK IAW AMM 33-53-00.SDR WX0A2015070272705Vertical Gyro · faultyCAPTAINS PFD BOUNCES UP & DOWN OCCASIONALLY CAUSING AUTOPILOT TO PITCH YOKE FWD & AFT RAPIDLY. SOON THEREAFTER AUTO THROTTLES, AUTOPILOT & FLIGHT DIRECTOR ALL FAILED. R & R VERTICAL GYRO IAW AMM 34-23-01. PERFORMED RTS IAW AMM 22-01-05. OPERATIONS CHECKED SDR WX0A2015050872569Reservoir · bypassingDURING DESCENT HYD PRESS DROPPED TO 0 & HYD QTY SHOT TO 19 QTS ON THE LT SIDE. RAN CHECKLIST & SYS CAME BACK AT 7000 FEET. NORMAL OPERATION AFTER THAT. TROUBLE SHOT HYD SYS FOUND LT RESERVOIR BYPASSING. R & R LT HYD RESERVOIR IAW AMM 29-10-01. SYS OPERATISDR WX0A2015041372523Warning System · false activationDURING FLIGHT, FIRE DETECTOR LOOP ANNUNCIATOR HAS ILLUMINATED & THE LOOP B ON THE RT ENG WAS ALSO ILLUMINATED. SWITCH TO LOOP A, GOT A GOOD FIRE TEST. LT SWITCH IN LOOP A POSITION IAW THE CHECKLIST. ACCOMPLISHED BITE TEST ON FIRE DETECTION UNIT IAW AMM TASKSDR WX0A2015022372432Battery · dischargedCEILING EMER LIGHTS INOPERATIVE FROM ROW 22 - 24. CANNOT LOCATE POWER SUPPLY. R & R BATTERIES FOR ROW 22 - 24. OPM CHECKED GOOD IAW AMM 33-53-00.SDR WX0A072349Power Supply · inoperativeFOUND ON WAKE UP, EXTERNAL EMER LIGHTS INOPERATIVE. REPLACED BATTERY POWER SUPPLY. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.SDR WX0A2015011572346Power Supply · inoperativeFOUR MID CABIN EMER LIGHTS INOPERATIVE. R & R EMER POWER SUPPLY AT ACFT RT ROW 24. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.SDR WX0A2014091072154Drain · cloggedABORTED TAKEOFF DUE TO AUTO SLAT FAIL ANNUNCIATOR. ABORT & FOUND NR 2 STALL WARNING COMPUTER WET WITH WATER. BLEW OUT DOOR & FLOOR DRAINS, REMOVED PEN FROM R1 DOOR BLOCKING DRAIN. CLEANED UP WATER IN E & E COMPARTMENT & UNSTUCK FWD E & E BAY DRAIN. R & R NRSDR WX0A2014081672096Battery · dischargedEMER LIGHTS FOR TAIL CONE & TUNNEL CEILING INOPERATIVE. REPLACED BATTERIES. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.SDR WX0A2014080572069Vertical Gyro · failedON DEPARTURE WHILE IN THE CLIMB THE LT FOLLOWED BY THE RT FLIGHT DIRECTORS FILED. LOST BOTH FD'S, FMA'S & AUTOPILOT. IAW WORK ORDER 228858 R & R NR 1 VG IAW AMM 34-23-01. RTS SHOWS GO FOR 1 & 2 IAW AMM 22-01-05. SYS OPERATIONS NORMAL.SDR WX0A071944Battery · dischargedFWD EMERGENCY FLASHLIGHT INOPERATIVE. R & R FWD FLASH BATTERY, OPERATIONS CHECKED GOOD IAW MM 25-60-00. THIS CLEARS MEL 25-09 SIT 1 DMI 8644 PLACARD REMOVED.SDR WX0A2013051371574Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A071567Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A2013032171538Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071497Bracket · crackedLEFT T/E BRACKET CRACKED O/B OF I/B SPOILER ACTUATOR. APPLIED DOUGLAS SERVICE BULLETIN (GROUP 1, CONDITION 2, OPTION 1) FOR TEMPORAY MD80-57-180 FIG 3 IAW SERVICE BULLETIN.SDR WX0A071495Frame · corrodedE&E BAY COMPARTMENT FRAME AT FS 200 CORRODED AT AFT SIDE BETWEEN L28L AND L28R. CUT OUT DAMAGED AREA, FABRICATED REPAIR PARTS AND INSTALLED.SDR WX0A071492Doubler · crackedLEFT WING L/E PREVIOUS REPAIRED #30 FROM M362 FOUND .750 INCH LENGTH CRACK IN INTERNAL DOUBLER. FABRICATED REPLACEMENT INTERNAL DOUBLER, LOCATED, DRILLED AND INSTALLED.SDR WX0A071491Seat Track · damagedLEFT CENTER SEAT TRACK AT FS 275.0 HAS DAMAGED HOLES. CUT OUT DAMAGED SECTION AND REPAIRED SEAT TRACK.SDR WX0A071488Vane · chafedRIGHT WING O/B FLAP I/B VANE L/E STATION XW150 CHAFED OUT OF LIMITS. REMOVED DAMAGED AREA, FABRICATED DOUBLER AND BONDED.SDR WX0A071487Vane · chafedLEFT WING O/B FLAP I/B VANE L/E STATION XW150 CHAFED OUT OF LIMITS. REMOVED DAMAGED AREA, FABRICATED DOUBLER, HOT BOND REPAIRED.SDR WX0A071446Cover · crackedR1 ESCAPE COVER CRACKED. REPAIRED, CLEANED AND PAINTED.SDR WX0A071434Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071344Battery · dischargedIT HAS BEEN REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATSDR WX0A071328Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071327Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A071299Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071298Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071136Ballast · malfunctionedFLIGHT CREW REPORTED READING LIGHTS IN ROW 27 D- E- F PRODUCE SMOKE WHEN TURNED ON. MAINTENANCE PERSONNEL INSPECTED AND FOUND UPPER SIDEWALL LIGHT BALLAST AND UPPER LIGHTS INOP. REMOVED AND REPLACED BALLAST IAW AMM 33-21-03, OPS CHECK GOOD. READING LIGHTS OSDR WX0A071134Line · crackedFLIGHT CREW REPORTED NORMAL OPERATION THROUGH FLIGHT LEVEL 240. OIL QUANTITY DECREASING, PRESSURE 46 PSI, QUANTITY DECREASED TO ZERO. OIL PRESSURE STARTED TO DECREASE, AT 37 PSI. RIGHT ENGINE SHUT DOWN, SINGLE ENGINE APPROACH TO NORMAL WEIGHT LANDING. MAINSDR WX0A070949Power Supply · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070948Power Supply · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070947Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070887Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070868Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070867Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070849Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070795Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070793Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070780Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070757Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
Back to N416NV, cancelled Feb 23, 2019