N417AA, cancelled Apr 19, 2018
Service difficulty reports · 35
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N417AA' AND deregistration_id = 'N417AA-2018-04-19' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N417AA' AND deregistration_id = 'N417AA-2018-04-19' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20090817LGA05Battery Pack · dischargedEMERGENCY LIGHT FOR ROW 20DEF INOPERATIVE. REPLACED AFT BATTERY PACK FOR EMERGENCY LIGHT FOR ROW 20DEF.SDR AALA20090817LGA04Battery Pack · dischargedFIRST CLASS EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR FIRST CLASS EMERGENCY LIGHTS.SDR AALA20090817LGA03Battery Pack · dischargedFORWARD EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR FORWARD EMERGENCY LIGHTS.SDR AALA2009032100624Battery Pack · not seatedLGA - EMERGENCY LIGHT AT ROW 18 INOPERATIVE. RESEATED ROW 18 BATTERY PACK.SDR AALA2009032100623Battery Pack · dischargedLGA - FIRST CLASS EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR FIRST CLASS EMERGENCY LIGHTS.SDR AALA2009032100621Portable Light · inoperativeLGA - FORWARD ENTRY PORTABLE EMERGENCY LIGHT INOPERATIVE. REPLACED PORTABLE EMERGENCY LIGHT AT FORWARD ENTRY.SDR AALA200800372Light · inoperativeDFW - EMERGENCY LIGHT AT SEAT 7D INOPERATIVE. REPLACED LIGHT ASSEMBLY FOR EMERGENCY LIGHT AT SEAT 7D. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA200800371Shroud · brokenDFW - EMERGENCY LIGHT AT SEAT 20D HAS BROKEN SHROUD. REPLACED SHROUD FOR EMERGENCY LIGHT AT SEAT 20D. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA200800373Light · inoperativeDFW - EMERGENCY LIGHT AT SEAT 28D INOPERATIVE. REPLACED LIGHT ASSEMBLY FOR EMERGENCY LIGHT AT SEAT 28D. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA200800374Lamp · inoperativeDFW - EMERGENCY LIGHT AT LEFT EXTERIOR OVERWING INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT LEFT EXTERIOR OVERWING. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20072314Battery · dislodgedLGA - EMERGENCY LIGHTS AT TAIL COMPARTMENT INOPERATIVE. RESET BATTERIES IN BATTERY PACK FOR EMERGENCY LIGHTS AT TAIL COMPARTMENT. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20072313Contact · dirtyLGA - EMERGENCY LIGHTS AT OVERHEAD SEAT ROWS 28 TO 30 INOPERATIVE. CLEANED CONTACTS ON BATTERY PACK FOR EMERGENCY LIGHTS AT OVERHEAD SEAT ROWS 28 TO 30. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20071265Battery Pack · inoperativeLGA - EMERGENCY LIGHTS AT SEAT ROWS 20 TO 32 INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT SEAT ROWS 20 TO 32. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20071264Battery Pack · inoperativeLGA - EMERGENCY LIGHTS AT SEAT ROWS 1 TO 19 INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT SEAT ROWS 1 TO 19. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20070783Battery Pack · inoperativeATL - EMERGENCY LIGHTS IN CABIN INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS IN CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20050303Battery Pack · inoperativeSFO - OVERHEAD EMERGENCY LIGHTS OVER ROWS 9 TO 11 INOPERATIVE. REPLACED BATTERY PACK FOR OVERHEAD EMERGENCY LIGHTS OVER ROWS 9 TO 11. SYSTEM GROUND CHECKED NORMAL OPERATION. (CLOSED)SDR AALA20050293Battery Pack · inoperativeBOS - LOW BATTERY IN EXIT EMERGENCY LIGHT AT CENTER AFT DOOR. REPLACED BATTERY PACK FOR EMERGENCY EXIT LIGHT AT CENTER AFT DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20050100Battery Pack · dischargedSAT - CEILING EMERGENCY LIGHTS AT LAST THREE ROWS IN CABIN INOPERATIVE. REPLACED BATTERY PACK FOR CEILING EMERGENCY LIGHTS AT LAST THREE ROWS. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20041212Battery Pack · dischargedMSP - OVERHEAD EMERGENCY LIGHTS AT AFT ROW 18 INOPERATIVE. REPLACED BATTERY PACK FOR OVERHEAD EMERGENCY LIGHTS FOR AFT ROW 18. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031282Battery · dischargedSAT EMERGENCY CEILING LIGHTS ABOVE ROWS 8, 9 AND 10 ILLUMINATING VERY DIM. REPLACED BATTERY FOR EMERGENCY CEILING LIGHTS ABOVE SEATS 9D, 9E AND 9F. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20030558Switch · defectiveDURING OVERNIGHT MAINTENANCE, EMERGENCY EAC BUS OFF LIGHT ILLUMINATES WHEN EMERGENCY POWER IS SELECTED. REPLACED EMERGENCY AC BUS LIGHT SWITCH. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030186Stringer · crackedTUL - FOUND STATION 1380 AND STRINGER 14 RT SKIN HAS CRACK EMITTING FROM RIVET HOLE. STOP DRILLED CRACK SPECIFIED BY QA 242, APPLIED DOUBLER PER SRM 53-01 FIG 2 SHT 3. (M)SDR AALA20030196Skin · crackedTUL - FOUND CRACK IN FUSELAGE SKIN AT RIVET STATION 1380 BETWEEN L14 AND L15 LEFT SIDE. STOP DRILLED CRACK SPECIFIED QA242. INSTALLED DOUBLER PER SRM 53-01 FIG 2 SHEET 3. (M)SDR AALA20021483Connector · looseDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT OVERHEAD LIGHTS AT SECTION 8-11 INOPERATIVE. SECURED BATTERY PACK CONNECTION. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20010857Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, FORWARD OVERWING EMERGENCY EXIT SIGN DIM. REPLACED FORWARD OVERWING EMERGENCY EXIT SIGN BATTERY PACK AT 20F. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20001285Connector · looseDFW - DURING OVERNIGHT MAINTENANCE, FORWARD EMERGENCY EXIT OVERWING LIGHT INOPERATIVE. RECONNECTED LOOSE CONNECTOR ON BATTERY PACK. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20000906Skin · gougedTUL - FOUND SKIN GOUGED AND DENTED STATION 1097 TO 1265 L28 AND 29R. REPLACED DAMAGED SECTION OF SKIN, WITH INTERNAL DOUBLERS PER ESO 80559 DATED 5/30/00. (M)SDR AALA20000732Turbine · failedORD - FLT 1229 - ON CLIMB-OUT, SMELL OF BURNING RUBBER IN CABIN, NO SMOKE OBSERVED. RETURNED AND LANDED ORD WITHOUT INCIDENT. REPLACED RIGHT COOLING TURBINE. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA20000131Socket · failedORD - FLT 0362 - DURING FLIGHT, STRONG ACRID SMELL (ELECTRICAL) THROUGHOUT COCKPIT AND CABIN. LANDED ORD WITHOUT INCIDENT. REPLACED UPPER CABIN LIGHT SOCKET AT SEAT 23D. INSPECTED ALL WIRING AND TRANSFORMERS FROM ROW 20 TO AFT. SYSTEM GROUND CHECKED, NORMASDR AALA982233Wire · looseDFW - DURING OVERNIGHT MAINTENANCE, TAIL CONE RELEASE HANDLE EMERGENCY EXIT LIGHT INOPERATIVE. TIGHTENED LOOSE TERMINAL AND GROUND WIRES. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA981925Oven · malfunctionedDFW - FLT 1642 - AFTER TAKEOFF, CREW AND PASSENGERS NOTED BURNING SMELL AND SMOKE. AIRCRAFT RETURNED DFW AND LANDED OVERWEIGHT WITHOUT INCIDENT. FOUND NR 3 GALLEY OVEN TO BE CAUSE OF REPORTED SMELL IN CABIN. REPLACED NR 3 GALLEY OVEN. ACCOMPLISHED OVERWEIGSDR AALA981716Clamp · failedORD - FLT 785 - EN ROUTE ORD - AUS CLIMBING THROUGH 500 FEET, THE TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED. LIGHT EXTINGUISHED WITH RIGHT PACK TURNED OFF. AIR INTERRUPTED AND RETURNED TO ORD. LANDED WITHOUT INCIDENT. FLIGHT ATTENDANT REPORTED TSDR AALA971862Wire · brokenDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BY FORWARD GALLEY FOUND INOPERATIVE. INSTALLED NEW EMERGENCY FLOOR LIGHT STRIP JUMPER WIRE FOR FORWARD GALLEY LIGHT STRIP. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA970819Coalescer · dirtyDFW - FLT 857 - EN ROUTE PBI/DFW, DURING CRUISE, SLIGHT SMOKE ODOR NOTED IN CABIN ON TWO OCCASIONS. NO OTHER ABNORMAL INDICATIONS AND AIRCRAFT PROCEEDED TO DFW, LANDING WITHOUT INCIDENT. ACCOMPLISHED PACK BURNOUT PROCEDURE AND REPLACED BOTH COALESCER BAGS. SDR AALA951905Strip · defectiveRDU - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BY FORWARD GALLEY FOUND INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT STRIP BY FORWARD GALLEY. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)
Back to N417AA, cancelled Apr 19, 2018