N419NV, cancelled May 27, 2025
Service difficulty reports · 40
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N419NV' AND deregistration_id = 'N419NV-2025-05-27' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N419NV' AND deregistration_id = 'N419NV-2025-05-27' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR WX0A2018081073367Ballast · burnedELECTRICAL BURNING ODOR IN THE CABIN. FOUND OVERHEAD LAMPS INOPERATIVE. REPLACED THE LAMPS AND BALLAST.SDR JR2R20180113176Doubler · crackedRIGHT LEADING EDGE XRS 114 INTERNAL DOUBLER CRACKED. REPAIRED IAW SRM 57-06B, FIG 9.SDR JR2R20180113175Doubler · crackedLEFT WING LEADING EDGE XRS 114, INTERNAL DOUBLER CRACKED. REPAIRED IAW SRM 57-06B, FIG 9.SDR JR2R201801100001Support · crackedLEFT WING LE SUPPORT CRACKED. REPAIRED THE SUPPORT IAW SRM 57-06B FIG 18.SDR JR2R20170108047Support · crackedLEFT WING LE SUPPORT CRACKED AT XFS 303. REMOVED AND REPLACED THE SUPPORT IAW SRM 51-30-5.SDR JR2R20170108046Support · crackedLEFT WING LE SUPPORT CRACKED AT APPROX XFS 309. REPAIRED THE SUPPORT IAW SRM 57-06B, FIG 18.SDR JR2R20180107153Fitting · crackedLOUVER CLIP CRACKED AT CANTED FRAME 1463 LONGERON 7L. REMOVED AND REPLACED CLIP WITH FABRICATED NEW CLIP IAW SRM 51-10-4, 51-30-5.SDR JR2R20180107152Fitting · crackedLOUVER CLIP CRACKED AT CANTED FRAME 1463 LONGERON 8R. REMOVED AND REPLACED CRACKED CLIP WITH FABRICATED NEW CLIP IAW SRM 51-10-4, 51-30-5.SDR WX0A2017012473222Relief Valve · faultyEMERGENCY DECLARED. DURING CRUISE THE FLOW LIGHT FLICKERED AND THEN CHANGED TO STEADY ON. F/A`S HEARD A BANG ON THE LT SIDE NEAR ROWS 16/17 AND CABIN INDICATED A RAPID CLIMB. R&R PRESSURE RELIEF VALVE (FWD).SDR WX0A2016120973207Cabin Pressure · failedCABIN FLOW LIGHT ILLUMINATED DURING DESCENT. INCREASED THRUST, BUT CABIN ALTITUDE CONTINUED TO CLIMB. EMERGENCY DECLARED. R & R CABIN PRESSURE SELECTOR, CABIN PRESSURE CONTROLLER, LT ACM, AND CABIN SAFETY VALVES.SDR JR2R20160705353Fairing · crackedVERTICAL STABILIZER UPPER FORWARD FAIRING AFT ATTACH FLANGE IS CRACKED. REPAIRED VERTICAL STABILIZER UPPER FORWARD FAIRING AFT FLANGE IAW SRM 55-01, FIGURE 2, SHEET 3.SDR JR2R20160705044Step · crackedAFT VENTRAL STAIRS UPPER STEP CHAFED AT CATWALK CONTACT POINT, UPON DISASSEMBLY, FOUND 2EA CRACKS ON AFT END OF STEP. R & R VENTRAL STAIR STEP IAW SRM 51-30-1, PARA 6.SDR WX0A2016040800130Battery Pack · inoperativeFOUND EMERGENCY LIGHT AT L1 DOOR INOPERATIVE. R & R THE BATTERIES. ALL OPS CHECKED OK IAW AMM 33-53-00.SDR WX0A2016040173121Sense Line · rupturedRIGHT ENG EPR READS UP TO 0.3 HIGH ERRATICALLY DURING FLIGHT. WITH HIGHER ALTITUDE CORRESPONDING TO GREATER DEVIATION. QRH 72.10 YIELDS NO HELP. FOUND NR 2 ENG PT2 LINE RUPTURED. R & R PT2 LINE IAW AMM 71-00-00-4-13B 40. LEAKED CHECKED SYS, FOUND SYS SATISDR WX0A2016032873114Sense Line · rupturedDURING THE CLIMB, NOTICEABLE SPLIT IN THE EPR AS THEY CLIMBED ABOVE FL 250. AT CRUISE AT FL 330 THERE WAS A .25 SPLIT IN THE EPR WITH THE N1 MATCHED. THE EPR WAS LOWER ON THE NR 1 ENG WITH THE N1S MATCHED. WITH THE EPRS MATCHED THERE WAS A 9% DIFFERENCE IN SDR WX0A2016030173096Moisture Trap · unsecureRIGHT ENG SLOW TO SPOOL ON TAKEOFF & INFLIGHT RT ENG LAGS. 7 - 10 SECONDS BEHIND RT ON TAKEOFF. IN AIR LAGS ENOUGH TO CREATE YAW BY LT ENG SPOOLING UP FASTER. PERFORMED TROUBLESHOOTING FOR SLOW ACCELERATION IAW AMM 72-00-04. FOUND FWD MOISTURE TRAP IMPROPESDR WX0A2015113000024Battery Pack · inoperativeCATWALK EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES ASSOCIATED WITH EMERGENCY LIGHTS, REF AMM 33-53-00. OPS CHECK GOOD.SDR WX0A2015092872903Line · leakingCREW O2 BOTTLE MAY HAVE LEAK IN THE SYS SOMEWHERE. STARTED DAY WITH 1500 PSI & DOWN TO 1300 ON ARRIVAL. NR O2 WAS USED AFTER THE INITIAL TEST & FOUND O2 LEAK AT OBSERVERS O2 LINE FITTING. REPLACED FITTING IAW AMM 20-12-03. REMOVED CREW O2 BOTTLE, SERVICED SDR WX0A2015090172841Light · inoperativeAFT FLIGHT ATTENDANT EMER EXIT LIGHTED SIGN INOPERATIVE. FOUND LIGHT TO BE DEACTIVATED IAW WDM 33-51-14.SDR WX0A2015080372769Battery Pack · dischargedL1 & R2 DOOR EMERGENCY EXIT LIGHT DIM. REPLACED BATTERY PACK. OPERATION CHECKED GOOD IAW 33-60-00.SDR WX0A2015071572730Ballast · faultyFLIGHT ATTENDANT REPORTS PLASTIC BURNING SMELL AROUND ROW 8A. R & R BALLAST ASSEMBLY SWITCH 7AB & 8AB. R & R BALLAST COVER IAW AMM 33-21-03. OPERATIONS CHECKED GOOD. COMPLIED WITH TASK CARD 21-059-002 TYPE 3, RAN PACKS NO ELEC ODOR FOUND.SDR WX0A2015041372528Unknown · odor2050Z THE FWD LAVATORY SMOKE DETECTOR WENT OFF. IAW FLIGHT ATTENDANT HE SAID HE SMELT ELEC SMOKE. IAW FLIGHT ATTENDANT`S OBSERVATION THE LAVATORY LOOKS OK. INSPECTED FWD LAVATORY, PERFORMED LAVATORY SMOKE DETECTOR TEST, OPERATIONS CHECKED NORMAL. NO FAULTSSDR WX0A2015033072493Battery Pack · dischargedFORWARD DROP CEILING EMER LIGHTS INOPERATIVE. R & R EMER BATTERY PACK AT STATION 386. GND OPERATIONS CHECKED GOOD.SDR WX0A2015012072365Fitting · crackedLEFT OVERWING FLOOR SUPPORT FITTING CRACKED STATION 864 & LBL 20. R & R SUPPORT FITTING STATION 864 LBL 20 IAW SRM 51-30-5.SDR WX0A072364Fitting · crackedLEFT OVERWING FLOOR SUPPORT FITTING CRACKED STATION 927 & LBL 20. R & R SUPPORT FITTING STATION 927 LBL 20 IAW SRM 51-30-5. WO 239572 M301 286 & WO 1011507 2700-0101.SDR WX0A2015011572348Battery · dischargedEMERGENCY LIGHTS IN TUNNEL CEILING & TWO IN UPPER TAIL CONE INOPERATIVE. REPLACED BATTERIES IN POWER SUPPLY. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.SDR WX0A2015011572347Power Supply · inoperativeEXTERIOR EMER LIGHTS INOPERATIVE. REPLACED EMER POWER SUPPLY IN AFT PIT. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.SDR WX0A2014121672305Battery · dischargedLEFT & RIGHT EXTERIOR EMER LIGHTS INOPERATIVE. PERFORMED BATTERY RECHARGE PROCEDURE IAW AMM 33-53-01. OPERATIONS CHECKED NORMAL AT THIS TIME.SDR WX0A2014122272311Light · inoperativeONE EMER LIGHT MISSING NEAR THE L1 DOOR ENTRANCE. PROVIDED ONE BULB IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.SDR WX0A2014100172180Light · inoperativeRIGHT FUSELAGE EMER LIGHT REQUIRES RELAMP. REPLACED OVERWING EMER EVACUATION LIGHT BULB RT. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.SDR WX0A071937Coalescer Bag · dirtyDURING INITIAL CLIMB FLIGHT ATTENDANT REPORTED FUEL SMELL IN THE GALLEY. TWO PRIOR WRITE UPS PAGES 476691 & 476689. AIR RETURN TO SFB. IAW WO 00222279 & LP'S 476253, 476254, 476255, 476259 & 476261 FOR TROUBLESHOOTING & CORRECTIVE ACTIONS. MX CTRL CONCURRESDR WX0A071791Battery · dischargedVENTRAL STAIRS OVERHEAD EMERGENCY LIGHTS INOPERATIVE & WILL NOT TEST. R & R BATTERIES IN BATTERY PACKS B5-27 & B5-28. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.SDR WX0A201310250033Longeron · corrodedMID CARGO LONGERON 29L CORRODED. PERMANENT REPAIR, REPAIRED LONGERON 29L IAW EA 15353.SDR WX0A2013083071676Door Frame · corrodedAFT CARGO DOOR CUT-OUT JAMB BEAM CORRODED AROUND RIV-NUTS (BLIND NUTS). REMOVED CORROSION, LOCATED, DRILLED, INSTALLED TITANIUM DOUBLER AND REPAIR PARTS IAW SRM 53-05, FIGURE 123, OPTION 1.SDR WX0A2013083071674Vane · chafedLEFT WING OTBD FLAP INBD VANE LT CHAFED 6" FROM INBD END. REMOVED DAMAGED SKIN, FABRICATED FILLER, DOUBLER, INSTALLED FASTENERS, AND HOT BONDED IAW SRM 51-70-2, PARA 18B.SDR WX0A071342Light · shortedPILOT: SMELL OF ELECTRICAL SMOKE REPORTED BY F/A'S BEFORE LANDING BUT NO VISIBLE SMOKE SEEN, REPORTED FROM FRONT TO BACK OF CABIN. FOUND LIGHT BULB ON OVERHEAD SIDE WALL ROW 28DEF SHORTING OUT. RELAMPED OVERHEAD SIDE WALL LIGHT IAW MM 33-21-03. OP'S CHECK NSDR WX0A2012031371125Skin · dentedUPPER EXTERNAL SKIN DENTED OUT OF LIMITS AT STA 1429 AND STA 1437, JUST BELOW LH DORSAL FIN ATTACH ANGLE. CUT OUT DAMAGED AREA, PERFORMED HFEC IAW MD NDT SRM 06-10-001. NO CRACKS NOTED. FABRICATED FILLER, DOUBLER, INTERNAL DOUBLER, LOCATED DRILLED AND INSTALSDR WX0A070915Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070890Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070697Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
Back to N419NV, cancelled May 27, 2025