N423NV, cancelled May 27, 2025

Service difficulty reports · 38

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N423NV' AND deregistration_id = 'N423NV-2025-05-27'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR WX0A2018111273372Sensor · faultedSPOILER DEPLOYED ANNUNCIATOR ILLIMINATED AND STAYED ON DURING DESCENT. EMERGENCY DECLARED. R & R THE LT INBD FLIGHT SPOILER DEPLOYED SENSOR.Nov 8, 2018 · N423NV · Doug DC983 · Drag Control SystemSDR JR2R20170831362Skin · gougedRIGHT WING OTBD FLAP LEADING EDGE, GOUGED IN SKIN AND DOUBLER. REPAIRED THE FLAP LEADING EDGE IAW EA 45-2017-102.Aug 31, 2017 · N423NV · Doug MD83 · Trailing Edge FlapsSDR JR2R20170827356Frame · crackedDAR FINDING, RADOME, LOWER RIGHT GUIDE PIN FASTNER AND FRAME CRACKED.Aug 27, 2017 · N423NV · Doug MD83 · Fuselage Main, FrameSDR JR2R20170826108Beam · corrodedAFT CARGO DOOR OPENING, LOWER BEAM HAS CORROSION BETWEEN FS 1155 TO 1212.Aug 26, 2017 · N423NV · Doug MD83 · Fuselage Main, StructureSDR WX0A2017070373270Blower · odorVENT BLOWER HAS DISTINCT OIL AND EXHAUST SMELL. COULD NOT DUPLICATE SMELL.Jul 1, 2017 · N423NV · Doug DC983 · Air Distribution FanSDR WX0A2015121100039Lamp · inoperativeEMERGENCY OVERHEAD LIGHT AT ROW 5 INOPERATIVE. RELAMPED OVERHEAD EMERGENCY LIGHT AT ROW 5. OPS CHECK GOOD IAW AMM 33-53-00.Dec 8, 2015 · N423NV · Doug DC983 · Emergency LightingSDR WX0A2015101572944Battery Pack · dischargedEMERGENCY STANDBY LIGHTS INOPERATIVE AT ROW 21, 23 & 24. R & R BATTERY PACK AT ROW 23R IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.Oct 12, 2015 · N423NV · Doug DC983 · Emergency LightingSDR WX0A2015092872907Battery · dischargedEMERGENCY & STANDBY LIGHTS INOPERATIVE ROWS 20 - 24. R & R BATTERIES AT POWER PACK LOCATIONS FOR ROWS 20 - 24 IAW AMM 33-53-00. OPERATIONS CHECKED GOOD AT THIS TIME.Sep 27, 2015 · N423NV · Doug DC983 · Emergency LightingSDR WX0A2015092872896Engine · making metalRIGHT OIL STRAINER CLOGGING ANNUNCIATORS ILLUMINATED IN FLIGHT. FOLLOWED QRH 72.16, DIVERTED IAW QRH INSTRUCTION. FOUND METAL IN THE OIL, REPLACED NR 2 ENG IAW TC 71-080-003. REF LOG PAGE 576743.Sep 19, 2015 · N423NV · Doug DC983 · Engine (Turbine/Turboprop)SDR WX0A2015092472884Engine · malfunctionedDURING CLIMB OUT IN CALM CLEAR AIR, FELT A HEAVY VIBRATION THROUGHOUT THE ENTIRE ACFT, IT ONLY LASTED A FEW SECONDS. R & R NR 2 ENG IAW TC 71-080-003. ACFT OK FOR SERVICE.Sep 19, 2015 · N423NV · Doug DC983 · Engine (Turbine/Turboprop)SDR WX0A2015072700058Battery Pack · inoperativeVENTRAL STAIRS CEILING EMERGENCY LIGHTS INOPERATIVE. R & R BATTERIES IN EMERGENCY LIGHTS BATTERY PACK B5-28 IAW AMM 33-53-00 & WDM 33-51-13. OPERATIONS CHECKED GOOD.Jul 25, 2015 · N423NV · Doug DC983 · Emergency LightingSDR WX0A2015072700057Battery Pack · inoperativeFOUND 6 CONSECUTIVE EMERGENCY CEILING LIGHTS INOPERATIVE. REPLACED 2 EACH EMERGENCY BATTERIES IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.Jul 24, 2015 · N423NV · Doug DC983 · Emergency LightingSDR WX0A2015061572659Gasket · blownUPON OPENING THE L1 DOOR ARRIVAL, THE TWO FWD FLIGHT ATTENDANTS, MYSELF & THE FIRST OFFICER SMELLED A FAINT FUEL SMELL, WHICH WE ASSUMED CAME FROM OUTSIDE. LATER DETERMINED THE SMELL WAS COMING FROM OUR VENTS VIA APU AIR. IMMEDIATELY SHUT THE APU AIR OFF & PJun 13, 2015 · N423NV · Doug DC983 · APU Engine Fuel and ControlSDR WX0A2015052772606Battery · dischargedFOUND ON WAKE UP, ROWS 21 - 24 EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES AT ROW 23 FWD SET. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.May 21, 2015 · N423NV · Doug DC983 · Emergency LightingSDR WX0A2015052072603Light · inoperativeAFT TAIL COMPARTMENT, TWO EMER EXIT LIGHTS INOPERATIVE. RELAMPED TWO EMER EXIT LIGHTS IN AFT TAIL COMPARTMENT IAW AMM 33-53-00. OPERATIONS CHECKED NORMAL.May 19, 2015 · N423NV · Doug DC983 · Emergency LightingSDR WX0A2015031972472Battery · dischargedTAIL CONE CEILING EMER EXIT LIGHTS INOPERATIVE. REPLACED BATTERIES IN POWER SUPPLY. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.Mar 17, 2015 · N423NV · Doug DC983 · Emergency LightingSDR WX0A072471Battery · dischargedINTERIOR FWD OVERWING EMER EXIT LIGHTS VERY DIM. REPLACED BATTERIES IN POWER SUPPLY. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.Mar 17, 2015 · N423NV · Doug DC983 · Emergency LightingSDR WX0A2015012672377Battery · dischargedROW 23 EMER LIGHTS INOPERATIVE. REPLACED BATTERIES AT 24DEF. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.Jan 21, 2015 · N423NV · Doug DC983 · Emergency LightingSDR WX0A2015012672370Ballast · faultyAIRCRAFT OUT OF SERVICE UNTIL 01/25. SHORTLY AFTER TAKEOFF BOTH LAVATORY SMOKE ALARMS WENT OFF. FLIGHT ATTENDANTS REPORTED BURNING SMELL. COMPLIED WITH QRH 26.9 & RETURNED TO FIELD. MULTIPLE CBS PULLED IAW CHECKLIST. COMPLIED WITH WO 00244014 & 00244013. Jan 19, 2015 · N423NV · Doug DC983 · Passenger Compartment LightingSDR WX0A2014081172084Battery · dischargedDURING EMER LIGHTS TEST, THE COCKPIT EMER LIGHTS WILL NOT REMAIN ILLUMINATED. R & R BATTERIES FOR COCKPIT EMER LIGHTS. OPERATIONS CHECKED GOOD IAW MM 33-55-00.Aug 10, 2014 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071995Fuel · leakingSMOKE IN THE CABIN DUE TO APU FUEL LEAK. INFO NOT AVAILABLE, WILL INCLUDE WHEN AVAILABLE.Jun 18, 2014 · N423NV · Doug MD83 · APU Engine Fuel and ControlSDR WX0A071765Compressor · stalledON TAXI OUT WE RECEIVED 5 COMPRESSOR STALLS. UNABLE TO DETERMINE WHICH ENG. CHECKED RIG & TRIM OF LT ENG IAW MD80-MM-71-00-00 CONFIG 1. DRAINED MOISTURE TRAP, CHECKED PRESSURIZATION & DUMP VLV IAW MD80-73-20-00, ACCOMPLISHED M739, OPERATIONS CHECKED NORMAL,Dec 2, 2013 · N423NV · Doug MD83 · Turbine Engine Compressor SectionSDR WX0A2013040171547Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AMar 29, 2013 · N423NV · Doug MD83 · Emergency LightingSDR WX0A2013040171548Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERMar 28, 2013 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071507Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 18, 2013 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071506Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 18, 2013 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071505Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 18, 2013 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071484Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 18, 2013 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071483Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 18, 2013 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071482Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 18, 2013 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071462Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 30, 2012 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071451Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 12, 2012 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071450Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 12, 2012 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071347Battery · dischargedIT HAS BEEN REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS AOct 5, 2012 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071330Battery · dischargedIT HAS BEEN REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATSep 23, 2012 · N423NV · Doug MD83 · Emergency LightingSDR WX0A071283Coalescer Bag · dirtyDURING INITIAL CLIMBOUT SUDDENLY GOT A VERY STRONG BURNING ODOR. PAX WERE COMPLAINING ABOUT EYE IRRITATION. NO VISIBLE SMOKE SIGNS. INITIATED AIR RETURN. INSTALLED NEW END UNION PACKING ON AUX PUMP LEAK, CHECK OK MM 29-01-05. REMOVED AND REPLACED COALESCEAug 19, 2012 · N423NV · Doug MD83 · Humidity Control SystemSDR WX0A071154Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AApr 5, 2012 · N423NV · Doug MD83 · Emergency LightingSDR WX0A0711545/2012Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AApr 5, 2012 · N423NV · Doug MD83 · Emergency Lighting
Back to N423NV, cancelled May 27, 2025