N424TE, cancelled Mar 31, 2003
Service difficulty reports · 145
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N424TE' AND deregistration_id = 'N424TE-2003-03-31' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N424TE' AND deregistration_id = 'N424TE-2003-03-31' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RAIA00211331Igniter · inoperative5465-BMI- LEFT ENGINE WILL NOT START. MAINTENANCE REMOVED AND REPLACED BOTH IGNITERS.SDR RAIA00211329Indicator · inoperative5499-MSM- FO's AIR SPEED INDICATOR DISPLAYED OFF FLAG. MAINTENANCE REMOVED AND REPLACED AIR SPEED INDICATOR, OPS CK OK.SDR RAIA00210260Battery Pack · discharged5460-STL- EMERGENCY LIGHTS AT SERVICE DOOR INOP. MAINTENANCE REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY BATTERY, OPS CK OK.SDR RAIA00210256Battery Pack · dischargedMX-PIA- EMERGENCY LIGHTS INOP. REMOVED AND REPLACED AFT EMERGENCY LIGHT BATTERY.SDR RAIA00210255Lamp · inoperative5535-STL- AFT EMERGENCY LIGHT MALFUNCTION. REMOVED AND REPLACED LIGHT BULB.SDR RAIA00207203Clevis5450-STL- TYPE 3 EMERGENCY EXIT FELL INTO THE CABIN. MAINTENANCE REMOVED AND REPLACED DOOR LATCH CLEVIS AND ADJUSTED DOOR LATCH MECHANISM, OPS CK OK.SDR RAIA00205139Relay5554-STL- FIRST OFFICER PITOT FAULT LIGHT ILLUMINATED. MAINTENANCE REMOVED AND REPLACED RELAY 33DA.SDR RAIA00204134Fuel Heater · malfunctioned5546-STL- DURING CLIMB LEFT FUEL HEATER INDICATED IN THE RED. MAINTENANCE INSPECTED AND PLACED ON DEFERRAL. LATER CLEARED DEFERRAL BY REMOVING AND REPLACING THE FUEL HEATER.SDR RAIA00204116Audio Panel · inoperative5522-STL- #1 COMM INOP, INTERCOM SCRATCHY. MAINTENANCE REMOVER AND REPLACED ACM AUDIO PANEL, OPS CK OK.SDR RAIA00202057Warning System · malfunctionedBMI- LEFT FUEL CENTRAL ANNUNCIATOR PANEL LIGHT ILLUMINATED DURING TAXI. MAINTENANCE TROUBLESHOT AND DEFERRED IAW ATR MEL 28-21-1.SDR RAIA00111003O-Ring · leaking7137-STL-GREEN HYDRAULIC SYSTEM WENT TO ZERO PSI. MAINTENANCE INSPECTED, REMOVED AND REPLACED LEAKING PRESSURE TRANSMITTER O-RING. LEAK CK OK IAW ATR MAINTENANCE MANUAL.SDR RAIA00110004Receiver · inoperative7125-PIA- WEATHER RADAR INOPERATIVE. MAINTENANCE REMOVED AND REPLACED WEATHER RADAR RECEIVER/TRANSMITTER.SDR RAIA00107011Battery · failed7003-STL-EMERGENCY LIGHTING REMAINS ON ALL THE TIME. MAINTENANCE INSPECTED AND REPLACED EMERGENCY LIGHT BATTERY PACK.SDR RAIA00107013Relay · failed7003-STL-LEFT ENGINE ATPCS UPTRIM TEST DOES NOT DROP NP WHEN PLACED IN ARM POSITION. MAINTENANCE DEFERRED ATPCS SYSTEM PER MEL. MAINTENANCE INSPECTED AND REPLACED RELAY 34KF, SYSTEM TESTS NORMALLY.SDR RAIA00103022Torque Sensor · failed7438-STL-DURING FINAL APPROACH NR 2 ENGINE WHEN INTO FEATHER. MAINTENANCE REMOVED AND REPLACED THE NR 2 TORQUE SIGNAL CONDITIONER IAW ATR42 MAINTENANCE MANUAL.SDR RAIA00103012Pseu · failed7406-STL- DURING CLIMB LANDING GEAR WOULD NOT RETRACT. MAINTENANCE REMOVED AND REPLACED THE PROXIMITY BOX.SDR RAIA00103007Transponder · inoperative7163-STL-CREW REPORTS BOTH TRANSPONDERS INOPERATIVE. MAINTENANCE INSPECTED AND REPLACED TRANSPONDER CONTROL HEAD.SDR RAIA00101015Wire · broken7434-STL- SERVICE DOOR WARNING LIGHT ILLUMINATED DURING TAXI OUT AND WOULD NOT GO OUT. MAINTENANCE REPAIRED BROKEN WIRE ON SERVICE DOOR IAW ATR42 MAINTENANCE MANUAL.SDR RAIA00101012Pitch Horn · failed7136-STL- DURING CLIMBOUT, RUDDER AND ELEVATOR HORN HEAT FAULTED. MAINTENANCE REMOVED AND REPLACED THE ELEVATOR HORN IAW ATR42 MAINTENANCE MANUAL.SDR RAIA00101009Starter Gen · failed7176-STL- DURING CLIMB NR 2 GENERATOR FAULTED IN FLIGHT AFTER TAKEOFF. MAINTENANCE REMOVED AND REPLACED THE NR 2 STARTER GENERATOR IAW ATR42 MAINTENANCE MANUAL.SDR RAIA0101008Control Unit · failed7158-STL- DURING CRUISE NR 2 DC GENERATOR FAILED. MAINTENANCE REMOVED AND REPLACED NR 2 GENERATOR CONTROL UNIT IAW ATR42 MAINTENANCE MANUAL.SDR RAIA0101005Windshield · cracked7541-STL- DURING CRUISE CAPTAINS FOREWARD WINDSHIELD CRACKED. MAINTENANCE REMOVED AND REPLACED THE WINDSHIELD IAW ATR42 MAINTENANCE MANUAL.SDR RAIA0012067Angle · damagedMX-STL-DURING MAINTENANCE CHECK FOUND RIGHT HAND "Z" ANGLE FLOOR BOARD SUPPORT HAS CORROSION. MAINTENANCE REMOVED AND REPLACED "Z" ANGLE IAW ATR42 SRM.SDR RAIA0012066Seat Track · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND RIGHT HAND FLIGHT ATTENDANT SEAT TRACK BETWEEN FUSALAGE FRAMES 40 AND 36 HAS CORROSION. MAINTENANCE REMOVED AND REPLACE RIGHT HAND FLIGHT ATTENDANT SEAT TRACK IAW ATR42 SRM.SDR RAIA0012065Floorbeam · corrodedMX-STL-DURING MAINTENANCE CHECK FLOORBEAM #36 TOP CAP HAS CORROSION. MAINTENANCE REMOVED AND REPLACED #36 FLOORBEAM IAW ATR42 SRM.SDR RAIA0012064Floorbeam · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND FLOORBEAM #38 TOP CAP WAS CORRODED. MAINTENANCE REMOVED AND REPLACED FLOORBEAM #38 IAW ATR42 SRM.SDR RAIA0012063Floorbeam · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND FLOORBEAM #39 TOP CAP IS CORRODED. MAINTENANCE REPAIRED #39 FLOORBEAM IAW ATR42 SRM.SDR RAIA0012062Door Frame · corrodedMX-STL-DURIG MAINTENANCE CHECK FOUND COCKPIT OVERHEAD ESCAPE HATCH WAS CORRODED ON INNER FRAME AND AROUND SCREW HOLES. MAINTENANCE REMOVED CORROSION AND TREATED AND PRIMED THE AREA IAW ATR42 SRM.SDR RAIA0012087Frame · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND CORROSION ON LEFT HAND FUSALAGE FRAME 19 ABOVE FLOOR TO WALL TRANSITION ANGLE. MAINTENANCE REMOVED CORROSION, TREATED AND PRIMED THE FRAME IAW ATR42 SRM.SDR RAIA0012086Frame · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND CORROSION ON LEFT HAND FUSALAGE FRAME 17A ABOVE FLOOR TO WALL TRANSITION ANGLE. MAINTENANCE REMOVED CORROSION, TREATED AND PRIMED FRAME IAW ATR42 SRM.SDR RAIA0012085Angle · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND LEFT HAND FLOOR TO WALL TRANSITION ANGLE IS CORRODED AT VARIOUS AREAS BETWEEN FUSALAGE FRAMES 20 AND 17. MAINTENANCE REMOVED CORROSION, TREATED AND PRIMED TRANSITION ANGLE IAW ATR42 SRM.SDR RAIA0012084Angle · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND RIGHT HAND FLOOR TO WALL TRANSITION ANGLE WAS CORRODED AT VARIOUS PLACES. MAINTENANCE REMOVED CORROSION, TREATED AND PRIMED TRANSITION ANGLE IAW ATR42 SRM.SDR RAIA0012083Bracket · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND RIGHT HAND FORWARD CABIN LOWER SIDEWALL ATTATCH BRACKETS WERE CORRODED BETWEEN FUSALAGE FRAMES 20 AND 17. MAINTENANCE REMOVED CORROSION TREATED AND PRIMED AREA IAW ATR42 SRM.SDR RAIA0012082Bracket · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND LEFT HAND CABIN LOWER SIDEWALL ATTATCH BRACKETS ARE CORRODED BETWEEN FUSALAGE FRAMES 20 AND 17. MAINTENANCE REMOVED AND REPLACED BRACKETS IAW ATR42 SRM.SDR RAIA0012081Frame · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND CORROSION ON FUSALAGE FRAME 9 AT FLOOR BEAM FASTENER HOLES. MAINTENANCE REPAIRED FRAME IAW ATR42 SRM.SDR RAIA0012080Stringer · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND STRINGER 13R HAS CORROSION AT FUSALAGE FRAME 7. MAINTENANCE REPAIRED STRINGER IAW ATR42 SRM.SDR RAIA0012079Floor Panel · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND COCKPIT RIGHT HAND FLOOR PANEL 212FF HAS CORROSION. MAINTENANCE REMOVED AND REPLACED FLOOR PANEL IAW ATR42 MAINTENANCE MANUAL.SDR RAIA0012078Floor Panel · corrodedMX-SYL-DURING MAINTENANCE CHECK FOUND COCKPIT FLOOR PANEL 211FF WAS CORRODED. MAINTENANCE REPAIRED FLOOR PANEL IAW ATR42 SRM.SDR RAIA0012077Plate · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND PAX DOOR 2ND AND 4TH TREAD PLATES ARE CORRODED. MAINTENANCE REMOVED AND REPLACED THE TREAD PLATES IAW ATR42 SRM.SDR RAIA0012076Stringer · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND CORROSION ON STRINGER 18L BETWEEN FUSALAGE FRAMES 17A AND 17. MAINTENANCE REMOVED CORROSION, TREATED AND PRIMED STRINGER 18L AREA IAW ATR42 SRM.SDR RAIA0012075Stringer · corrodedMX-STL-DURING MAMNTENANCE CHECK FOUND CORROSION ON STRINGER 17L BETWEEN FUSALAGE FRAMES 18 AND 19. MAINTENANCE REMOVED CORROSION, TREATED AND PRIMED AREA IAW ATR42 SRM.SDR RAIA0012074Stringer · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND CORROSION ON STRINGERS 19L, 18L, 17L, 21R AND 18R BETWEEN FUSALAGE FRAMES 20 AND 19. MAINTENANCE REMOVED CORROSION , TREATED AND PRIMED AREA IAW ATR42 SRM.SDR RAIA0012073Stringer · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND CORROSION ON STRINGERS 19L, 18L, 17L, 18R AND 17R BETWEEN FUSALAGE FRAMES 21 AND 20. MAINTENANCE REMOVED CORROSION AND TREATED AND PRIMED AREA IAW ATR42 SRM.SDR RAIA0012072Sill · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND INTERNAL CORROSION (AT NUT PLATES) ON FWD CARGO DOOR SILL. MAINTENANCE REMOVED CORROSION AND TREATED AND PRIMED AREA IAW ATR42 SRM.SDR RAIA0012071Sill · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND PAX DOOR SILL PLATE HAS CORROSION. MAINTENANCE REMOVED AND REPLACED PAX DOOR SILL PLATE IAW ATR42 SRM.SDR RAIA0012070Sill · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND SURFACE CORROSION AT FUSALAGE FRAME 37 RIGHT HAND AT SILL PLATE. MAINTENANCE REMOVED CORROSION, TREATED AND PRIMED AREA IAW ATR42 SRM.SDR RAIA0012069Seat Track · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND RIGHT HAND OUT BOARD SEAT TRACK HAS CORROSION BETWEEN FUSALAGE FRAMES 36 & 34. MAINTENANCE REPAIRED THE SEAT TRACK IAW ATR42 SRM.SDR RAIA0012068Seat Track · corrodedMX-STL-DURING MAINTENANCE CHECK FOUND LEFT HAND FLIGHT ATTENDANT SEAT TRACK BETWEEN FUSALAGE FRAMES 38 & 36 HAS CORROSION.MAINTENANCE REMOVED AND REPLACED THE SEAT TRACK IAW ATR42 SRM.SDR RAIA0009013Downlock Switch · failed7108-STL- LEFT MAIN LANDING GEAR WOULD NOT RETRACT. MAINTENANCE INSPECTED AND REPLACED LEFT MAIN LANDING GEAR DOWNLOCK SWITCH.SDR RAIA0008001Packing · failed7177-MSN- GREEN HYDRAULIC LOW PRESSURE INDICATION ILLUMINATED ON LANDING. MAINTENANCE INSPECTED AND REPLACED GREEN SYSTEM HYDRAULIC PRESSURE TRANSMITTER O-RING.