N424XJ, cancelled Apr 15, 2022
Service difficulty reports · 104
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N424XJ' AND deregistration_id = 'N424XJ-2022-04-15' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N424XJ' AND deregistration_id = 'N424XJ-2022-04-15' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR PNSA2016021402Indicator · brokenAIRSPEED INDICATOR FLAGS AT 70 KTS. REPLACED CAPTAIN'S AIRSPEED INDICATOR.SDR PNSA2015112715Gcu · failedLEFT ACFT GENERATOR LIGHT ON, R & R LEFT AC GCU.SDR PNSA2015112402Power Supply · failedEMERGENCY POWER SUPPLY FAIL SCHEDULED INSPECTION, R & R.SDR PNSA2015112401Duct · damagedSTRONG BURNING ODOR UP FRONT. R & R LEFT LOWER INLET DUCT.SDR PNSA2015101602Power Supply · failedEMERGENCY LIGHTING POWER SUPPLY FAILED TEST, R & R.SDR PNSA2015031301Downlock Switch · failedDURING APPROACH INTO OUR DESTINATION, OUR GEAR DOWN LOCKED LIGHT FOR THE LT MAIN GEAR DID NOT LIGHT UP. RETURNED TO BASE. R & R LT MLG DOWNLOCK SWITCH.SDR PNSA2015022202Warning Message · activatedCWP "FLAPS" LIGHT ON FLAP OVERHEAD LIGHT, GREEN, ON IN FLIGHT INTERMITTENT. COMPLIED WITH MECHANIC RIGGING AND ELECTRICAL RIGGING OP CHECKED GOOD.SDR PNSA2014040901Power Supply · failedEMERGENCY LIGHT POWER SUPPLY FAILED CHECK. REPLACED POWER SUPPLY AT 21LN.SDR PNSA2013102004Power Supply · no testDURING THE 6 MONTH EMERGENCY LIGHTING POWER SUPPLY INSPECTION, 20LN, 21LN, AND 24LN, FAILED THE CHECK.SDR PNSA2013090301Warning Light · illuminatedRUDDER LIMITER LIGHT ON IN FLIGHT.SDR MALA100148Power Supply · failed21LN FAILED CAPACITY TEST. R & R 21LN EMERGENCY BATTERY PN 3301-51 IAW SF340 AMM 24-35-10 SN OFF 1288 SN ON 1405. OPS CHECK GOOD.SDR MALA100119Structure · chafedFRAME 630-112 IS CHAFED IN RT SIDE JUST ABOVE SEAT TRACK. BLENDED AND APPLIED DOUBLER IAW EO S53775.SDR MALA100118Web · chafedWEB AT 288-294 CHAFED FROM STAIR SLIDE. REPAIRED WEB AT STA 288-294 IAW EO S53362.SDR MAL2008F00044Skin · dentedDURING THE 2Y AND N4K NOTED DENT IN RT FUSELAGE AT STA 389. REPAIRED IAW EO# S53009.SDR MAL2008F00047Skin · puncturedDURING THE 2Y AND N4K THE RT ELEVATOR UPPER SKIN PUNCTURED AT HS68.66. REPAIRED IAW EO S53229.SDR MAL2008F00037Skin · dentedDURING THE 2Y AND N4K NOTED 4 DENTS IN TAIL CONE BETWEEN STA797 AND 803. 1 ABOVE AND 3 BELOW SL1604. REPAIRED IAW EO#S53620.SDR MAL2008F00049Skin · dentedDURING THE 2Y AND N4K NOTED THE LOWER FUSELAGE CENTER WING FAIRING AT STA562 HAS SEVERAL DENTS. REPAIRED DENTS ON LOWER FUSELAGE CENTER TRAILING COVER FAIRING IAW MAL EO S51031.SDR MAL2008F00046Skin · dentedDURING THE 2Y AND N4K NOTED 13 DENTS IN UPPER SKIN OF RT HORIZONTAL STABILIZER. REPAIRED IAW EO S55017 & S55160.SDR MAL2008F00042Skin · dentedDURING THE 2Y AND N4K NOTED 2 DENTS NOTED IN RT OVERWING EXIT EXTERIOR SKIN. REPAIRED IAW EO S52028 & S52139.SDR MAL2008F00041Skin · dentedDURING THE 2Y AND N4K NOTED 3 DENTS NOTED IN TAIL SECTION STA 622-853. REPAIRED IAW EO#S53229.SDR MAL2008F00040Skin · dentedDURING THE 2Y AND N4K NOTED 32 DENTS NOTED IN THE LT FUSELAGE STA 322-392 AND 5 DENTS NOTED ON THE RT FUSELAGE STA 353-392. REPAIRED IAW EO#S53619.SDR MAL2008F00032Circuit Breaker · poppedCB L8 POPPED, PREVIOUSLY RESET ONCE PER POM CB POLICY. RESET CB L8.SDR MAS2008F00060Switch · failedON SHUT DOWN CURRENT BREAKER L8 TRIPPED; EMERGENCY LIGHT STAYED ON; RESET BREAKER, THIS SHUT OFF EMERGENCY LIGHTS. REMOVED AND REPLACED EMERGENCY LIGHT SWITCH. (S)SDR MAS2008F00059Light · inoperativeFLOOR TRACK LIGHTING INOPERATIVE ROWS 2 AND 3. REMOVED AND REPLACED FLOOR TRACK LIGHTING STRIP. (S)SDR MAS2008F00058Switch · malfunctionedFLIGHT ATTENDANT REPORTED THE EMERGENCY LIGHT ARMED STATUS LIGHT ON THE FA PANEL DID NOT ILLUMINATE; HOWEVER, FLIGHT DECK VERIFIED EMERGENCY LIGHTS WERE ARMED. REMOVED AND REPLACED F/A CONTROL PANEL SWITCH. (S)SDR MALA080028Light · inoperativeLT AFT COVE EMERGENCY LIGHT INOP, DISCOVERED DURING LC1. REMOVED AND REPLACED DEFECTIVE LIGHT ASSY 2LA005115-20.SDR MALA070163Skin · damagedREMOVED RT FLAP FOR FOM FOR REPAIRS TO LOWER SIDE FOR EO NR S57154. REPAIRED FLAP SKIN DAMAGE PER EO NR S57154. INSTALLED SERVICEABLE FLAP ASSEMBLY PN ON/OFF: 7257800-574; SN OFF: 1315, SN ON: 1307, IAW AMM 27-53-10.
SDR MALA060603Seat Track · corrodedTHE SEAT TRACK AT LBL 18.3, BETWEEN FS 297 AND 318 IS CORRODED OUT OF LIMITS. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO NR S53342. REF: EAMS WORK ORDER 214677 TASK 1513.SDR MALA060602Floor Support · corrodedFLOOR SUPPORT FRAME, AT FS 292 AND RBL 18.3, IS CORRODED OUT OF LIMITS. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO NR S53108. REF: EAMS WORK ORDER 214677 TASK 1511, IPM-12 ITEM NR 1.SDR MALA060432Battery Pack · failedFOUND POWER SUPPLY 21LN TO HAVE FAILED BATTERY CAPACITY CHECK. REPLACED POWER SUPPLY WITH SERVICEABLE UNIT. OPS CHECK GOOD.SDR MALA060197Battery Pack · no testFAILED CAP CHECK PER CMM WO 406706. REPLACED BATTERY PACK.SDR MALA060132Floor Support · corrodedDURING N4K BRIDGE CHECK IN BNA, FOUND FLOOR FLANGE PN 7253712-193 IS CORRODED OUT OF LIMITS AND HAS BEEN REMOVED AND REPLACED IAW SRM 51-40-21. REF: EAMS WORK ORDER 213551 TASK 1547.SDR MALA060131Frame · chafedDURING N4K BRIDGE CHECK IN BNA, FOUND AFT FORMER PN 7271115-037 ON COWLING PANEL NR 453CL IS CHAFED AND HAS BEEN REMOVED AND REPLACED IAW SRM 51-40-21. REF: EAMS WORK ORDER 213551 TASK 4508.SDR MALA060128Seat Track · corrodedDURING N4K BRIDGE CHECK IN BNA, PREVIOUS REPAIR TO SEAT TRACK BL 0 IS CORRODED, BETWEEN FS 296 TO FS 305 AND HAS BEEN REMOVED AND REPLACED IAW SRM 51-40-22. REF: EAMS WORK ORDER 213551 TASK 1515.SDR MALA060114Frame · chafedDURING N4K BRIDGE CHECK IN BNA, FOUND THE AFT FORMER PN 7271115-037 ON COWLING 463CL IS CHAFED AND HAS BEEN REMOVED AND REPLACED IAW SRM 51-40-21. REF: EAMS WORK ORDER 213551 TASK 4501SDR MALA060115Floor Support · corrodedDURING N4K BRIDGE CHECK IN BNA, FOUND FLOOR FLANGE AT RBL 33 IS CORRODED BETWEEN FS438 TO FS 512 AND HAS BEEN REPAIRED FOLLOWING THE PROCEDURES AS OUTLINED IN SRM 51-70-30 AND INSTALLED IAW SRM 51-40-21. REF: EAMS WORK ORDER 213551 TASK 1548.SDR MALA060116Floor Support · corrodedDURING N4K BRIDGE CHECK IN BNA, FOUND FLOOR FLANGE AT RBL 33 IS CORRODED, BETWEEN FS366 TO FS420, AND HAS BEEN REPAIRED FOLLOWING THE PROCEDURES AS OUTLINED IN SRM 51-70-30 AND INSTALLED IAW SRM 51-40-21. REF: EAMS WORK ORDER 213551 TASK 1553.SDR MALA060112Web · corrodedDURING 4K BRIDGE CHECK IN BNA, FOUND WEB, PN 7253721-439, BETWEEN FS 288 AND FS 294 IS CORRODED AND HAS BEEN REMOVED AND REPLACED, REF:EAMS WORK ORDER 213551 TASK 1509.SDR MALA060117Frame · corrodedDURING N4K BRIDGE CHECK IN BNA, FOUND FRAME AT FS 258 FROM LBL 18 RBL 18 IS CORRODED AND HAS BEEN REPAIRED IAW MESABA EO#S53102. REF: EAMS WORK ORDER 213551 TASK 1556.SDR MALA060113Seat Track · corrodedDURING N4K BRIDGE CHECK IN BNA, FOUND SEAT TRACK AT LBLK 18.3 IS CORRODED AND HAS BEEN REPAIRED BETWEEN FS 296 TO FS 319 IAW MESABA EO#S53342. REF: EAMS WORK ORDER 213551 TASK 1514.SDR MALA060111Frame · corrodedDURING 4K BRIDGE CHECK IN BNA FOUND FRAME AT FS 294 IS CORRODED AND HAS BEEN REPAIRED IAW MESABA EOS53108.SDR MALA060110Intercostal · corrodedDURING 4K BRIDGE CHECK IN BNA FOUND INTERCOSTAL AT FS 272 AND RBL 10, IS CORRODED OUT OF LIMITS AND HAS BEEN REPLACED WITH A FABRICATED PART.SDR MALA060109Rail · corrodedDURING 4K BRIDGE CHECK IN BNA FOUND AIRSTAIR RAIL ASSY, P/N 7253710-871, IS CORRODED AND HAS BEEN REMOVED AND REPLACED IAW SRM 51-40-22/23.SDR MALA060106Nozzle · chafedDURING 4K BRIDGE CHECK IN BNA FOUND RIGHT LOWER EXHAUST NOZZLE IS CHAFED AND HAS BEEN REPAIRED IAW MESABA EOS54133.SDR MALA060105Nozzle · chafedDURING 4K BRIDGE CHECK IN BNA FOUND LEFT LOWER EXHAUST NAZZLE IS CHAFED AND HAS BEEN REPAIRED IAW MESABA EOS54133.SDR MALA060104Bridge · chafedDURING 4K BRIDGE CHECK IN BNA FOUND LT NACELLE AT NS 197 IS CHAFED AND HAS BEEN REPAIRED 2/27/06 IAW MESABA EOS54150.SDR MALA060103Door Frame · corrodedDURING 4K BRIDGE CHECK IN BNA FOUND LEFT COCKPIT DOOR POST IS CORRODED AND HAS BEEN REPAIRED ON 2/28/06 IN IAW MESABA EOS53185.SDR MALA050817Extinguisher · brokenDURING INSPECTION, FOUND LAV FIRE EXTINGUISHER BROKEN AND DISCHARGED. INSTALLED NEW FIRE EXTINGUISHER IN LAV POSITION IAW SF 340 AMM CH 26 AS REQUIRED.SDR MALA050674Weu · failedBITE LIGHT ON LEFT SIDE OF OVERHEAD LIGHTS DO NOT ILLUMINATE WITH UPPER LAMPS TESTS. REMOVED AND REPLACED WEU PER AMM 31-50-05-4. OPS CHECK GOOD, P/N ON 006WS00, S/N ON 1596, P/N OFF 005WS00, S/N OFF 1464.SDR MALA050502Battery · failedBATTERY FAILED CAPACITY CHECK.
Back to N424XJ, cancelled Apr 15, 2022