N427SW, cancelled Mar 8, 2023
Service difficulty reports · 162
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N427SW' AND deregistration_id = 'N427SW-2023-03-08' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N427SW' AND deregistration_id = 'N427SW-2023-03-08' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA201440260Floor Support · corrodedLEFT UPPER SURFACE OF PRESSURE FLOOR SUPPORT FROM BS 445 TO 559 HAS CORROSION. BLENDED CORROSION IAW REO. ALL BLENDS WITHIN LIMITS.SDR SWIA201440259Pressure Deck · crackedPRESSURE FLOOR IS CRACKED AT BS 460 JUST INBD OF RBL 9. REPAIRED PRESSURE FLOOR CRACK AT FS460.0 JUST INBD RBL9.0 IAW REO, LEAK CHECK GOOD. COMPLIED WITH ST CARD.SDR SWIA201440258Cable · crackedPARKING BRAKE CABLE HAS A CRACK AT 202 PRESSURE BULKHEAD, C-CHECK, RO 11/30/14, COMPLIED WITH CUT-AWAY DAMAGED AREA AND DOUBLER INSTALLED AT LT 202 PRESSURE BULKHEAD REF REO AND SR. NO LEAKS FOUND. COMPLIED WITH ST CARD.SDR SWIA201440257Rib · gougedREAR PRESSURE BULKHEAD FORWARD FACE UPPER RIB BETWEEN DOOR TRACK AND FUSELAGE GOUGED. C-CHECK, RO 11/30/14, REPAIRED SUPPORT BRACKET, RIB, PN 601R36008-175 ON FS 621 BULKHEAD LT SIDE REF REO. ALL STEP COMPLIED WITH.SDR SWIA201440256Bracket · crackedREAR PRESSURE BULKHEAD WEB AFT SIDE S 625 HAS A RT SIDE BRACKET CRACKED. R & R CRACKED BRACKET IAW SRM AND REO.SDR SWIA201440255Bracket · crackedREAR PRESSURE BULKHEAD WEB AFT SIDE BS 625 HAS A LT SIDE BRACKET CRACKED. R & R CRACKED BRACKET IAW SRM AND REO.SDR SWIA201440254Skin · chafedRIGHT SURFACE OF THE CENTER WING LOWER PLANK UNDER PANEL 193AB CHAFED. REPAIRED RIGHT SURFACE OF THE CENTER WING LOWER PLANK COMMON TO PANEL 193AB REF REO. ALL STEPS COMPLIED WITH.SDR SWIA201440253Skin · corrodedEXTERNAL LOWER SKIN PANEL BS 559+48, STR 27 HAS CORROSION. FOUND TO BE WITHIN ALLOWABLE DAMAGE IAW EA,. BLENDED CORRODED AREA IAW SRM. NO LEAKS NOTED.SDR SWIA201440252Skin · corrodedEXTERNAL LOWER SKIN PANEL AT BS 559+112, STR 27 HAS CORROSION. BLENDED CORROSION IAW SRM. FOUND TO BE WITHIN ALLOWABLE LIMITS IAW EA. RESTORED FINISH IAW SRM. NO LEAKS NOTED.SDR SWIA201440251Shroud · chafedLEFT AILERON UPPER SHROUD CHAFED. BLENDED CHAFE ON LT AILERON UPPER SKIN SHROUD AND FOUND TO BE WITHIN LIMITS, IAW REO..SDR SWIA201440250Skin · corrodedAVIONICS BAY DOOR SURROUND HAS CORROSION. BLENDED AVIONICS BAY DOOR SURROUND, BS 364 - 394 AND S25L - 25R, FOUND TO BE IN LIMITS IAW REO.SDR SWIA201440249Skin · chafedLEFT MAIN LANDING GEAR DOOR HAS CHAFING AT INBD SIDE SKIN. REPAIRED THE CHAFE ON INBD SIDE OF LT MLG DOOR, REPAIRED IAW EA.SDR SWIA201440248Skin · chafedRT AILERON ACCESS PANEL 699BB HAS CHAFING. , BLENDED DAMAGE AND FOUND TO BE WITHIN LIMITS IAW REO. REPAIR COMPLETE IAW REO.SDR SWIA201440247Skin · chafedRT AILERON UPPER SHROUD CHAFED. BLENDED DAMAGE TO RT AILERON UPPER SHROUD, FOUND TO BE WITHIN LIMITS IAW REO.SDR SWIA201440246Skin · chafedRIGHT INBD FLAP HAS CHAFING FROM GROUND WIRE UNDER PANEL 684AB. BLENDED CHAFE ON RT INBD FLAP UNDER PANEL IAW REO. FOUND TO BE WITHIN LIMITS.SDR SWIA201440245Skin · chafedRT INBD FLAP HAS CHAFING FROM GROUND WIRE UNDER PANEL NR 684CB, BLENDED CHAFE ON RT INBD FLAP UNDER PANEL 684CB, IAW REO. FOUND TO BE WITHIN LIMITS.SDR SWIA201440244Skin · chafedVANE SKIN, RT INBD FLAP HAS CHAFING AT L/E CLOSE TO WS 137.012. R & R NEW L/E INBD FLAP VANE IAW SRM, IAW REO.SDR SWIA201440243Skin · chafedVANE SKIN, RIGHT INBD FLAP HAS CHAFING AT L/E CLOSE TO WS 98.509, C-CHECK, RT INBD FLAP VANE SKIN AT WS 98.509 OUT OF LIMITS. INSTALLED NEW FABRICATED CENTER CAP ONTO RT INBD FLAP VANE, PN 601R14303-52, REF SRM AND STS EA.SDR SWIA201440242Vane · chafedVANE SKIN, RIGHT INBD FLAP HAS CHAFING AT L/E CLOSE TO WS 60.005, C-CHECK, BLENDED CHAFE ON THE INBD END OF THE RT INBD FLAP VANE L/E CLOSE TO WS60.005, REF REO. FOUND TO BE WITHIN LIMITS.SDR SWIA201439700Shutoff Valve · failedDURING CLIMBOUT, RECEIVED A LT PACK HIGH PRESSURE INDICATION. PERFORMED QRH PROCEDURE. PACK WOULD STILL OVER PRESSURE. R & R THE LT PRSOV IAW AMM. OPS CHECKED GOOD.SDR SWIA201333319Light · inoperativeEMERGENCY OVERHEAD LIGHT IS BURNED OUT. (FLT 4674) RELAMPED EMERGENCY LIGHT.SDR SWIA201333052Battery Pack · dischargedAFT CEILING EMERGENCY EXIT SIGN BY OVERWING EXIT AND OVERHEAD EMERGENCY EXIT LIGHT AFT OF EXIT SIGN DO NOT ILLUMINATE. (FLT 4754) REPLACED EMERGENCY BATTERY PACK NR 3 P/N: AD-2013-1A S/N ON: 76608 S/N OFF: 41230SDR SWIA201332819Light · inoperativeAFT SIDE OF THE OVERHEAD EMERGENCY SIGN AT ROW 8 DOES NOT ILLUMINATE. (SERVICE) RELAMPED EMERGENCY SIGN.SDR SWIA201332791Light · inoperativeNR 3 EMERGENCY OVERHEAD LIGHT IS BURNED OUT. (FLT 4681) RELAMPED EMERGENCY LIGHT.SDR SWIA201332687Controller · faultyON ROTATION, ADG DEPLOYED. BOTH MAIN GENERATORS REMAINED ONLINE WITH NO POWER INTERRUPTION. TAXIED OUT WITH BOTH MAIN GENERATORS ON-LINE. (FLT 4765) REPLACED ADG AUTO-DEPLOY CONTROLLER IAW AMM AND STOWED ADG. P/N: 82046-5 S/N: 407 S/N OFF: 1193.SDR SWIA201232565Floor Support · corrodedFLOOR SUPPORT AT FS 559.0+112 TO FS 621.0 AT LBL 27 HAS CORROSION AROUND NUT PLATES. (C-CHECK) REPLACED FLOOR SUPPORT AT FS 559.0+112 TO FS 621.0 AT LBL 27 IAW REO.SDR SWIA201232567Bulkhead · crackedCRACK NOTED AND MARKED ON FS 621 AFT PRESSURE BULKHEAD WEB FWD FACE AT LBL 27.50 WL 131.0 ABOVE AFT CARGO DOOR AFT TRACK. (C-CHECK) INSTALLED FABRICATED REPAIR PARTS ON FS 621 BULKHEAD IAW REO.SDR SWIA201232566Bulkhead · crackedCRACK NOTED AND MARKED ON FS 621 AFT PRESSURE BULKHEAD WEB FWD FACE AT LBL 46.99 WL 108.64 AT LINTEL FITTING. (C-CHECK) INSTALLED FABRICATED REPAIR PARTS IAW REO.SDR SWIA201232569Post · crackedCRACKS NOTED AND MARKED IN RIGHT FS 409+128 VERT POST AT RBL 18 AND I/B C-CHANNEL IN AFT RADIUS. (C-CHECK) INSTALLED NEW VERTICAL POST AT FS 409 +128 RBL 18 IAW SRM AND REO.SDR SWIA201232568Post · crackedCRACKS NOTED AND MARKED IN LEFT FS 409+128 VERT POST AT LBL 18 AND O/B C-CHANNEL IN AFT RADIUS. (C-CHECK) INSTALLED NEW VERTICAL POST AT FS 409 +128 LBL 18 IAW SRM AND IAW REO.SDR SWIA201232421Light · inoperativeEMERGENCY LIGHTS IN OVERHEAD EXIT SIGN DO NOT ILLUMINATE. (FLT 4495) RELAMPED EMERGENCY LIGHTS.SDR SWIA201232383Pin · unsecureCLIMBING THOUGH 11,000 FT. OVBD COOL, INBD COOL FAIL CAUTION MSG, CABIN ALTERNATIVE WARNING MSG, COULD NOT PRESSURIZE. (FLT 4734) RE-SECURED PIN ON PASSENGER DOOR OUTER HANDLE PROXIMITY SWITCH.SDR SWIA201232320Relay · failedGEAR DOWN WOULDN'T GO DOWN AND LOCK UNTIL PUMP 3B PUT IN - ON - POSITION. (FLT 4791) REPLACED RELAY K10D8 IAW AMM P/N: M83726/28-5000P.SDR SWIA201232048Light · inoperativeEMERGENCY LIGHT OVER ROW 5 IS BURNED OUT. (FLT 5373) RELAMPED EMERGENCY LIGHT.SDR SWIA201231754Cover · missingFLOOR LEVEL EMERGENCY LIGHT COVER BY BOARDING DOOR IS MISSING. (FLT 4546) REPLACED EMERGENCY FLOOR LEVEL FLOOD LIGHT ASSEMBLY IN IAW AMM.SDR SWIA201231387Light · inoperativeRIGHT OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. (FLT 4842) RELAMPED EMERGENCY LIGHT.SDR SWIA201230962Light · inoperativeNR 2 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 4848) RELAMPED EMERGENCY LIGHT.SDR SWIA201230615Light · inoperativeNR 4 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 4731) RELAMPED EMERGENCY LIGHT.SDR SWIA201230271Light · inoperativeNR 6 EXTERIOR EMERGENCY LIGHT ON RIGHT WING IS OUT. (FLT 7810) RELAMPED EMERGENCY LIGHT.SDR SWIA201230265Light · inoperativeFLOOR LEVEL EMERGENCY FLOOD LIGHT BY MAIN CABIN DOOR IS BURNED OUT. (FLT 4598) RELAMPED EMERGENCY LIGHT.SDR SWIA201229974Light · inoperativeNR 2 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 4832) RELAMPED EMERGENCY LIGHT.SDR SWIA201229521Wire · damaged(FLT 4759) CAPTAIN'S FLOODLIGHT WIRES WERE EXPOSED, ARCED, AND POPPED CIRCUIT BREAKER. REPLACED PILOT SIDE CONSOLE FLOOD LIGHT.SDR SWIA201129069Accumulator · leakingGEAR DISAGREE AND "HYD 3 LO PRESS" MESSAGE. (FLT 4632) REPLACED NR 3 BRAKE ACCUMULATOR FOR LEAKING AIR INTO HYDRAULIC SYSTEM.SDR SWIA201128519Hydraulic System · contaminatedON TAKEOFF WHEN GEAR SELECTED UP BOTH 3 HYDRAULIC PUMPS WERE CYCLING ON AND OFF. LANDING GEAR WAS SLOW TO RETRACT AND RECEIVED A GEAR DISAGREE MESSAGE. (FLT 4456) BLED A LARGE QUANTITY OF AIR IN SYSTEM HYDRAULIC SYSTEM 3.SDR SWIA201127997Light · inoperativeNR 2 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 4568) RELAMPED EMERGENCY LIGHT.SDR SWIA201127581Light · inoperativeNR 3 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 4493) RELAMPED EMERGENCY LIGHT.SDR SWIA201127169Light · inoperativeOVERHEAD EMERGENCY LIGHT AT ROW 4 IS OUT. (FLT 4635) RELAMPED EMERGENCY LIGHT.SDR SWIA201127032Proximity Sensor · failedNOSE GEAR DISAGREE. (FLT 4604) REPLACE NR 1 NLG DOWNLOCK PROX SENSOR.SDR SWIA201126948Wire Harness · damagedNOSE GEAR DISAGREE. (FLT 4521) REPLACED NLG HARNESS.SDR SWIA201126848Light · inoperativeNR 2 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 4682) RELAMPED EMERGENCY LIGHT.