N429SW, cancelled Jul 30, 2023
Service difficulty reports · 113
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N429SW' AND deregistration_id = 'N429SW-2023-07-30' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N429SW' AND deregistration_id = 'N429SW-2023-07-30' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA200413352Element · brokenRECEIVED MULTIPLE NUISANCE AMBER MLG OVERHEAT FAIL MESSAGES. UPON TOUCHDOWN, RECEIVED MASTER WARNING MLG BAY OVERHEAT WITH AURAL GEAR BAY OVERHEAT. REMOVED AND REPLACED BROKEN LT WHEEL BIN ELEMENT PER CRJ MM 26-14-01. OPS CHECK GOOD.SDR SWIA200412772Computer · malfunctionedYAW DAMP NR 2 DISENGAGED ON THE GROUND AT SLC AND WOULD NOT RE-ENGAGE. REMOVED AND REPLACED NR 2 FCC CARD PER CRJ MM 22-12-14. OPS CHECKS GOOD.SDR SWIA200412756Control Panel · malfunctionedYAW DAMPER 2 WOULD NOT ENGAGE. REMOVED AND REPLACED YAW DAMPER PANEL. OPS CHECK GOOD AT THIS TIME. P/N OFF: 601R51594-1.SDR SWIA200311731Floor Support · crackedFS 621 LT FLOOR SUPPORT ANGLE CRACKED. FOUND DURING C-CHECK INSPECTION. REPAIRED DAMAGED AREA IAW CRJ REO 601R-53-61-117. ANGLE P/N: 601R-53-61-117-1 REP, ANGLE P/N: 601R-53-61-117-3.SDR SWIA200311730Intercostal · crackedFS 625 STR 14L LT INTERCOSTAL ANGLE FOUND CRACKED. FOUND DURING C-CHECK INSPECTION. REPLACED ANGLE IAW CRJ SRM 51-40-11 & 51-42-06. P/N: 601-35012-51.SDR SWIA200311729Floorbeam · crackedFS 280 LBL 9.0 FLOORBEAM I/B & O/B ANGLES CRACKED. FOUND DURING C-CHECK INSPECTION. ANGLES REPLACED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-13, AND 51-42-21. P/N: 601R3113-57.SDR SWIA200311728Floorbeam · crackedFS 280 RBL 9.0 FLOORBEAM I/B ANGLE CRACKED. FOUND DURING C-CHECK INSPECTION. ANGLE REPLACED IAW CRJ SRM 51-40-11, 51-42-06 AND 51-42-21. P/N: 601R3113-58.SDR SWIA200211574Scissors · disconnectedNOSE WHEEL GEAR DISAGREE MESSAGE WHEN GEAR RETRACTED. RETURNED TO AUS. FOUND NOSE WHEEL STEERING LINKS (SCISSORS) DISCONNECTED. RECONNECTED, INSPECTED NOSE GEAR TIRES. NO VISUAL DAMAGE NOTED.SDR SWIA200211353Control Unit · malfunctionedSTAB TRIM CHANNEL 1 STATUS MESSAGE. COULD NOT ENGAGE STAB TRIM CHANNEL 1. MOTOR 1 FAILURE ON HSTCU ON GROUND TEST. REPLACED HSTA ACTUATOR IAW 27-40-00 AND REPLACED MOTOR CONTROL UNIT IAW 27-42-05. OPS CHECK GOOD.SDR SWIA200211313Spring · out of adjustCABIN DOOR DIFFICULT TO OPEN. ADJUSTED SPRING ROD ASSEMBLY IAW CRJ MM 52-11-02. OPS CHECK GOOD.SDR SWIA200211304Light · inoperativeCEILING EMERGENCY LIGHT INOP AT ROW 2. REMOVED THE INOP BULB AND INSTALLED A NEW BULB. OPERATIONAL CHECK GOOD.SDR SWIA200211303Pump · leakingLOSS OF ALL NR 3 SYSTEM HYDRAULIC FLUID. REMOVED AND REPLACED ELECTRIC HYDRAULIC PUMP 3A WITH SERVICEABLE UNIT IAW MM 29-12-03. OPS AND LEAK CHECK GOOD.SDR SWIA200210648Door · openSTALL FAIL MESSAGE AFTER TAKEOFF. RETURNED TO SLC. FOUND OXYGEN SERVICE DOOR OPEN, CLOSED DOOR. OPS CHECK GOOD.