N471AA, cancelled Mar 1, 2018
Service difficulty reports · 61
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N471AA' AND deregistration_id = 'N471AA-2018-03-01' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N471AA' AND deregistration_id = 'N471AA-2018-03-01' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20151211013B-Nut · looseEMERGENCY DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING DECENT WHEN FLAPS 15 WAS SELECTED, THE RT HYD QTY & PRESS DROPPED TO ZERO. FOUND HYD FLUID LEAKING AT RT THRUST REVERSER B NUT. TIGHTENED B NUT. OPERATIONAL & LEAK CHECKED GOOD IAW AMM 29SDR AALA20150929004Water Separator · unserviceablePASSING THROUGH 20,000 FEET, PRESSURIZATION FLOW LIGHT ILLUMINATED. CABIN PRESS BEGAN TO CLIMB, AT MAX RATE, RT PACK 0 FLOW. QRH REMEDIES INEFFECTIVE TO RESTORE RT PACK & LT PACK SINGLE OPERATIONS WOULD NOT HOLD CABIN PRESS. FLIGHT RETURNED & LANDED WITHOUTSDR AALA20141213004Pressure Switch · defectiveAIR INTERRUPT, DIVERTED & EMER DECLARED & LANDING UNEVENTFUL. ACFT NOT OVERWEIGHT. DURING CRUISE, LT ENG OIL FILTER BYPASS LIGHT ILLUMINATED. R & R LT ENG OIL FILTER DIFFERENTIAL PRESS SWITCH ASSEMBLY IAW AMM 79-35-01-201. PERFORMED OPERATION & LEAK CHECK.SDR AALA20141102005Frame · corrodedCORROSION ON FRAME AT FUSELAGE STATION 1155 BETWEEN LONGERONS 26 & 27 RT. REMOVED CORROSION & INSTALLED REPAIR DOUBLER IAW ENGINEERING AUTHORIZATION MD80-53-037226.SDR AALA20141005003Former · crackedRIGHT WING LE NR 4 SLAT TRACK INBD FORMER IS CRACKED. INSTALLED RT WING NR 4 INBD FORMER DOUBLER & HAT BUSHING IAW WORK CARD 57-98-06.SDR AALA20141005002Former · crackedLEFT WING LE NR 4 SLAT TRACK INBD FORMER IS CRACKED. INSTALLED LT WING NR 4 SLAT INBD FORMER DOUBLER & HAT BUSHING IAW WORK CARD 57-98-05.SDR AALA20131204002Shroud · brokenEMERGENCY LIGHT AT SEAT 26DEF HAS BROKEN SHROUD. R & R SHROUD FOR SEAT 26DEF EMERGENCY LIGHT. OPERATIONS CHECKED NORMAL.SDR AALA20130801004Battery · not seatedTAIL COMPARTMENT EMERGENCY LIGHTS ABOVE CATWALK INOPERATIVE. RESEATED & SECURED BATTERIES IN BATTERY PACK LOCATED IN RT AFT LAVATORY. OPERATIONS CHECKED NORMAL.SDR AALA20130521016Skin · crackedLT FUSELAGE SKIN AT STATION 1309 AND LONGERON 7 LT CRACKED. INSTALLED DOUBLER IAW EA MD80-53-029892.SDR AALA20130510004Control Unit · inoperativeDFW - CREW REPORTED MULTIPLE AC POWER INTERRUPTIONS WITH CHIMES IN THE LAVATORIES AND FIRST OFFICER INSTRUMENTS BLINKING. EMERGENCY DECLARED FLIGHT RETURNED DFW LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED LEFT TR-2 AND BUSS CONTROL UNITSDR AALA20130130022Battery Pack · out of positionCEILING EMERGENCY LIGHTS FROM ROWS 12 TO 16 INOPERATIVE. REPOSITIONED BATTERY PACK FOR CEILING EMERGENCY LIGHTS FROM ROWS 12 TO 16. OPS CHECK NORMAL.SDR AALA20120809013Panel · damagedSEVERAL HOLES LOCATED ON THE LOWER DORSAL. INSTALLED DOUBLER REPAIR ON THE LOWER DORSAL PANEL BELOW STATION ZFS 52.267 PER BOEING MD-80 SRM 55-03-00.SDR AALA20120416009Oven · odiferousDFW - CREW REPORTED STRONG ELECTRICAL SMOKE SMELL IN COCKPIT. EMERGENCY DECLARED FLIGHT RETURNED DFW LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED FORWARD OVENS THAT WERE EMITTING ODOR. SYSTEM GROUND CHECK NORMAL OPERATION.SDR AALA20111216TUL04Track · corrodedAFT CARGO CORROSION ON LEFT TIE DOWN TRACK FROM STATIONS 1174 TO 1212. INSTALLED NEW TRACK PER AARD 51-10-00-5.SDR AALA20111216TUL03Track · corrodedCORROSION ON LEFT TIE DOWN TRACK FROM STATIONS 1250 TO 1287. INSTALLED NEW TRACK PER AARD 51-10-00-5.SDR AALA20111215TUL20Fitting · damagedFORWARD CARGO STATION 380 BEAM/PAN T CLIP HAS DEEP TOOLING MARKS ON IT. REINSTALLED INTERCOSTAL AT STATION 380 BETWEEN LONGERONS 28 AND 29 RIGHT AND INSTALLED NEW T-CLIP (BEAM TO INTERCOSTAL ATTACH) AT STATION 380 PER SRM 51-30-00 AND AARD 51-10-00-5.SDR AALA20111213TUL04Intercostal · crackedINTERCOSTAL CRACKED IN CEILING STATIONS 1287 TO 1309. REPLACED INTERCOSTAL AT STATIONS 1287 TO 1309 PER AARD 51-10-00-5.SDR AALA20111212TUL01Seat Track · corrodedSEAT TRACK NUMBER SIX, CORROSION REMOVAL OUT OF LIMITS FROM STATIONS 1031 TO 1309. INSTALLED SERVICEABLE SEAT TRACK NUMBER SIX FROM STATION 1031-1309 AS PER AARD 51-10-00-5.SDR AALA20111210TUL17Cusp Web · puncturedPUNCTURE IN RIGHT CUSP SHEET AT STATION 1063 INBOARD OF NUMBER 6 SEAT TRACK. INSTALLED DOUBLER PER AARD 53-20-00-16.SDR AALA20111210TUL05Cusp Web · puncturedPUNCTURE IN RIGHT CUSP SHEET AT STATION 1015 INBOARD OF NUMBER 6 TRACK. INSTALLED DOUBLER PER AARD 53-20-00-16.SDR AALA20111210TUL04Cargo Track · corrodedLEFT MID CARGO TIE DOWN TRACK, STATION 720, LEFT CLIPNUT EAR CORRODED. INSTALLED TIE DOWN TRACK DOUBLER PER AARD 53-20-00-13.SDR AALA20111210TUL01Cusp Web · corrodedLEFT CUSP STATIONS 254 TO 257, CORRODED. REMOVED DAMAGED CUSP MATERIAL AND INSTALLED DOUBLER REPAIR AS PER AARD 53-20-00-16.SDR AALA20111222TUL21Cusp Web · crackedRIGHT CUSP CRACKED AT STATION 886. ACCOMPLISHED DOUBLER REPAIR PER AARD 53-20-00-16.SDR AALA20111222TUL20Cusp Web · crackedRIGHT CUSP CRACKED AT STATION 1015 INBOARD OF SEAT TRACK NUMBER 6. ACCOMPLISHED DOUBLER REPAIR PER AARD 53-20-00-16.SDR AALA20111222TUL19Cusp Web · crackedRIGHT CUSP CRACKED AT STATION 1063 INBOARD OF SEAT TRACK NUMBER 6. ACCOMPLISHED DOUBLER REPAIR PER AARD 53-20-00-16.SDR AALA20111222TUL18Cusp Web · crackedRIGHT CUSP CRACKED AT STATION 845 OUTBOARD NUMBER 6 SEAT TRACK MOUNTING HOLES. ACCOMPLISHED DOUBLER REPAIR PER 53-20-00-16.SDR AALA20111222TUL17Cusp Web · corrodedLEFT CUSP STATIONS 254 TO 257 CORRODED. REPLACED DOUBLER PER AARD 53-20-00-16.SDR AALA20111222TUL16Cusp Web · corrodedRIGHT CUSP STATION 1174 CORRODED. REPLACED DOUBLER PER AARD 53-20-00-16.SDR AALA20111222TUL15Cusp Web · corrodedRIGHT CUSP STATION 1193 CORRODED. REPLACED DOUBLER PER AARD 53-20-00-16.SDR AALA20111222TUL14Cusp Web · corrodedRIGHT CUSP STATION 886 CORRODED. REPLACED DOUBLER PER AARD 53-20-00-16.SDR AALA20111209TUL05Cusp Web · corrodedCORROSION ON CUSP AT RIGHT STATION 1174. REMOVED DAMAGED CUSP MATERIAL AND INSTALLED DOUBLER REPAIR PER AARD 53-20-00-16.SDR AALA20111209TUL04Cusp Web · corrodedCORROSION ON CUSP AT RIGHT STATION 1193. REMOVED DAMAGED CUSP AND INSTALLED DOUBLER REPAIR PER AARD 53-20-00-16.SDR AALA20111209TUL03Cusp Web · defectiveSTATION 888 RIGHT CUSP SHEET HAS EXTRA HOLE APPROXIMATELY 3/16 IN DIAMETER BETWEEN CENTER AFT HORSE COLLAR ATTACHMENT HOLE AND THE OUTBOARD EDGE OF NUMBER 6 SEAT TRACK. REMOVED DAMAGED AREA BY ROUTING DAMAGE OUT PER AARD53-20-00-16. INSTALLED DOUBLER PER AARSDR AALA20110630LGA01Battery · not seatedSEVERAL INTERIOR EMERGENCY LIGHTS FROM ROW 16 AFT DID NOT WORK WHEN PERFORMING FUNCTIONAL TEST ON OVERNIGHT "B" CHECK. RESEATED EMERGENCY LIGHT BATTERIES IN AFT CABIN AND IN RIGHT AFT LAVATORY. OPS CHECK NORMAL.SDR AALA20110310LAS01Battery Pack · dischargedBOTH FORWARD INTERIOR OVERWING EXIT EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR OVERWING EMERGENCY EVACUATION LIGHTS. OPS CHECK NORMAL.SDR AALA20110117DFW02Switch · faultyDFW - CREW REPORTED DURING DESCENT RIGHT HYDRAULIC PRESSURE LOW LIGHT ILLUMINATED WHEN SELECTING PUMP TO HIGH. EMERGENCY DECLARED FLIGHT LANDED DFW WITHOUT INCIDENT. INITIAL INSPECTION AT GATE SHOWED NO FLUID LOSS, QUANTITY OK. AIRCRAFT REMOVED FROM SERVICESDR AALA20101005ORD01Drum · faultyORD - CREW REPORTED DURING THE AUTOLAND WITH DIRECT FLIGHT GUIDANCE SYSTEM ONE SELECTED THE AUTOPILOT PULSED AT 50 FEET AND THEN DISCONNECTED. FLIGHT ACCOMPLISHED A GO AROUND AND LANDED ORD WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED ELEVATOR SDR AALA2009062700004Battery · not seatedLGAM - CEILING EMERGENCY LIGHTS FROM ROW 13 TO 16 INOPERATIVE. RESEATED BATTERIES FOR CEILING EMERGENCY LIGHTS FROM ROW 13 TO 16.SDR AALA200802397ABattery Pack · inoperativeLGA - FORWARD SEAT MOUNTED EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK AT LEFT NUMBER TWO DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA200802396BBattery Pack · dischargedLGA - FORWARD SEAT MOUNTED EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK AT SEAT ROW 20DEF. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20071916Hose · crackedSTL INFLIGHT T1646/10OCT - ON APPROACH, LOST RIGHT HYDRAULIC PRESSURE AND EXTENDED ALTERNATE GEAR HANDLE. LANDED STL WITHOUT INCIDENT. FOUND GROUND SPOILER DOWN PRESSURE LINE CRACKED AT FLARE AT CONTROL VALVE. REPLACED HOSE. SYSTEM GROUND CHECKED NORMAL OPSDR AALA20071433Battery Pack · inoperativeBOS - EMERGENCY LIGHTS AT RIGHT AND LEFT AFT AUXILIARY DOORS INOPERATIVE. REPLACED BATTERY PACK AT BIN 20DEF FOR EMERGENCY LIGHT AT SEAT ROW 22D. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20060020Module · inoperativeLGA - EMERGENCY AISLE LIGHTING IN FORWARD SECTION INOPERATIVE. REPLACED MODULE FOR EMERGENCY AISLE LIGHTING IN FORWARD SECTION. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20050037Battery · dischargedBOS - FORWARD OVERWING DOOR EXIT LIGHTS INOPERATIVE. REPLACED BATTERIES ON PATTERY PACK FOR FORWARD OVERWING DOOR EXIT LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20041263Fitting · looseDFW - EN ROUTE DFW-PHL SMOKE IN CABIN. RETURNED DFW AND LANDED WITHOUT INCIDENT. FOUND LOOSE HYDRAULIC LIGHT TEE FITTING ABOVE LEFT HAND THRUST REVERSER CONTROL VALVE. TIGHTENED HYDRAULIC LIGHT TEE FITTING ABOVE LEFT HAND THRUST REVERSER CONTROL VALVE. ACCSDR AALA20041262Coalescer Bag · dirtyMCI - EN ROUTE MCI-DFW SMOKE IN CABIN. RETURNED MCI AND LANDED WITHOUT INCIDENT. CHECKED FOR HYDRAULIC AND OIL LEAKS. CHANGED COALESCER BAGS AND PERFORMED PACK BURN. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040782Battery Pack · inoperativeDEN - EXTERIOR EMERGENCY EXIT SIGN LIGHT INOPERATIVE. REPLACED BATTERY PACK B549 FOR EXTERIOR EMERGENCY EXIT SIGN LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20030733Battery · dischargedDFW - EMERGENCY LIGHT AT AFT GALLEY FLOOR JUST FORWARD OF DOOR IS INOPERATIVE. REPLACED BATTERY AND CHARGER MODULE. SYSTEM GROND CHECKED NORMAL OPERATION. (M)SDR AALA20030732Charger · inoperativeDFW - EMERGENCY LIGHT IN CEILING AT ROWS 8, 9, 10, 11 ARE INOPERATIVE. REPLACED BATTERY CHARGER ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20020163Battery · dischargedDFW - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT LIGHTS IN FORWARD ENTRANCE AND GALLEY AREA ARE INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT BATTERY AND CHARGER ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
Back to N471AA, cancelled Mar 1, 2018