N487AA, cancelled Jun 5, 2021
Service difficulty reports · 88
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N487AA' AND deregistration_id = 'N487AA-2021-06-05' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N487AA' AND deregistration_id = 'N487AA-2021-06-05' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20160215002Generator · malfunctionedON TAKEOFF, THE LT ENG GEN STARTED CYCLING OFF & ON. SHUT OFF LT GEN & STARTED APU. THE CREW DECLARED AN EMER & THE FLIGHT RETURNED WITHOUT FURTHER INCIDENT. PLACED LT ENG GEN ON MEL DEFERRAL. THE ACFT WAS GNDED.SDR AALA20151217004Battery Pack · dischargedREFERENCE WORK CARD 0801. EMER LIGHTS ROW 28 - 32 FAILED TO TEST. REPLACED EMER LIGHT BATTERY PACK B5-107 IAW AMM 33-53-00. TESTED OK.SDR AALA20151217003Battery Pack · dischargedREFERENCE WORK CARD 0801. EMER LIGHTS ROW 22 - 27 FAILED TO TEST. REPLACED EMER LIGHT BATTERY PACK B5-106 IAW AMM 33-53-00. TESTED OK.SDR AALA20151217002Battery Pack · dischargedREFERENCE WORK CARD 0801. EMERGENCY LIGHTS ROW 17 - 21 FAILED TO TEST. REPLACED EMER LIGHT BATTERY PACK B5-104 IAW AMM 33-53-00. TESTED OK.SDR AALA20151217001Battery Pack · dischargedREFERENCE WORK CARD 5403, EGRESS POWER SUPPLY AB5-1 FAILS TEST. REPLACED EGRESS LIGHT POWER SUPPLY AB5-1 BATTERY PACK IAW AMM 33-60-98. TESTED OK.SDR AALA20151211001Transducer · damagedAIRCRAFT WAS GNDED. DURING TAKEOFF ROLL, WHEEL NOT TURNING LIGHT ILLUMINATED. TAKEOFF ABORTED PRIOR TO 80 KNOTS. FOUND BROKEN PINS AT NR 2 WHEEL SPEED TRANSDUCER. R & R TRANSDUCER IAW AMM 32-43-02.SDR AALA20150914006Stiffener · crackedCRACK IN STATION 1418 FRAME WHERE L2R TERMINATES. R & R AFT STIFFENER AT STATION 1418, L5L TO L5R IAW EA 254341.SDR AALA20150909013Frame · crackedDURING LC21 CHECK, CRACKS WERE FOUND COMMON TO THE 5967113-1 & 5967113-501 FRAME CAPS & THE 5967114-505 FRAME WEB AT FUSELAGE 1437 COMMON TO THE 4918093 DORSAL FITTINGS AT L2L & L2R. REPAIRED FRAME CAPS & WEB EA 253748. SEE ALSO AALA20150905002 & AALA2015090SDR AALA20150909012Frame · crackedDURING LC21 CHECK, CRACKS WERE FOUND COMMON TO THE 5967113-1 & 5967113-501 FRAME CAPS & THE 5967114-505 FRAME WEB AT FUSELAGE 1437 COMMON TO THE 4918093 DORSAL FITTINGS AT L2L & L2R. REPAIRED FRAME CAPS & WEB EA 253748. SEE ALSO AALA20150905002 & AALA2015090SDR AALA20150905002Frame · crackedDURING LC21 CHECK, CRACKS WERE FOUND COMMON TO THE 5967113-1 & 5967113-501 FRAME CAPS & THE 5967114-505 FRAME WEB AT FS 1437 COMMON TO THE 4918093 DORSAL FITTINGS AT L2L & L2R. REPAIRED FRAME CAPS & WEB EA 253748. SEE ALSO AALA20150909012 & AALA20150909013.SDR AALA20150825008Skin · crackedFUSELAGE SKIN WAS FOUND CRACKED AT TWO LOCATIONS, STATION 1437 ABOVE & BELOW LONGERON 3L. PERFORMED DOUBLER & TRIPLER REPAIR IAW EA 253684.SDR AALA20150813009Bracket · crackedSTOP PAD BRACKET CRACKED ON FWD SIDE OF FWD CARGO DOOR AT CTR OF DOOR. R & R DOOR STOP PAD BRACKET IAW AARD 51-00-05-1 & DWG 5910141.SDR AALA20150813007Bracket · crackedSTOP PAD BRACKET CRACKED ON FWD SIDE OF FWD CARGO DOOR AT LOWER CORNER. R & R DOOR STOP PAD BRACKET IAW AARD 51-00-05-1 & DWG 5910141.SDR AALA20150813005Bracket · crackedSTOP PAD BRACKET CRACKED ON FWD SIDE OF FWD CARGO DOOR AT UPPER CORNER. R & R DOOR STOP PAD BRACKET IAW AARD 51-00-05-1 & DWG 5910141.SDR AALA20150813004Bracket · crackedSTOP PAD BRACKET CRACKED ON FWD SIDE OF MID CARGO DOOR AT 2ND FROM BOTTOM OF DOOR. R & R DOOR STOP PAD BRACKET IAW AARD 51-00-05-1 & DWG 5910141.SDR AALA20150813012Skin · crackedCRACKS IN FUSELAGE SKIN AT STATION 1437 BETWEEN LONGERONS 3R & 4R. INSTALLED DOUBLER REPAIR IAW SRM 53-04-00.SDR AALA20150418006Bulb · burned outEMERGENCY TAIL LIGHTS AT TAIL CONE & AFT FLIGHT ATTENDANT SEAT INOPERATIVE. REPLACED THE LAMPS FOR BOTH LIGHTS. OPERATIONALLY CHECKED GOOD.SDR AALA20150225007Longeron · crackedLONGERON 25 LT IS CRACKED AT FS 200 & 160. R & R LONGERON SECTION IAW SRM 53-02-00.SDR AALA20150225005Longeron · crackedLONGERON 24 LT CRACKED AT FS 200. R & R LONGERON SECTION IAW SRM 53-02-00.SDR AALA20150225004Longeron · crackedLONGERON 23 LT IS CRACKED AT FS 200. R & R LONGERON SECTION IAW SRM 53-02-00.SDR AALA20150217021Rib · crackedRIGHT WING NR 4 SLAT TRACK LE INBD SUPPORT RIB CRACKED. INSTALLED REPAIR DOUBLER IAW EA 57-038624 DATED 16 FEB 2015.SDR AALA20150217020Rib · crackedLEFT WING NR 4 SLAT TRACK LE INBD SUPPORT RIB CRACKED. INSTALLED REPAIR DOUBLER IAW EA MD80-57-038624 DATED 16 FEB 2015.SDR AALA20140304020Skin · damagedLT HAND FWD FLANGES OF VERTICAL STABILIZER & LE SKIN DAMAGED. ACCOMPLISHED REPAIR TO STABILIZER IAW EA MD80 55-033866 & SRM 55-03 FIGURE 29 & 30.SDR AALA20140303003Structure · damagedVERTICAL STAB LT HAND HOLE, 4TH HOLE BELOW STATION ZFS 52.267 ELONGATED. INSTALLED BUSHING & STRAP REPAIR IAW DRAWING SG09550005.SDR AALA20140301001Longeron · crackedAFT ACCESSORY LONGERON 2 LT IS CRACKED AT AFT END OF STATION 1418. REPLACED LONGERON 2 LT & SPLICE IAW SRMS 53-02-00, 53-02-00-001 & DRAWING DDK2782.SDR AALA20131019002Smoke Detector · faultyLT HAND AFT LAVATORY SMOKE DETECTOR WOULD NOT TEST. INSTALLED NEW SMOKE DETECTOR. OPERATIONS CHECKED NORMAL.SDR AALA20130706008Duct · leakingTAIL COMPARTMENT HIGH TEMPERATURE LIGHT ILLUMINATED ON CLIMB-OUT. FOUND DUCT LEAKING BETWEEN THE RT PRESSURE REGULATOR VALVE & THE FLOW CONTROL VALVE AT A SENSE LINE UNION. REPLACED DUCT. SYSTEM GROUND CHECKED NORMALSDR AALA20130304003Switch · inoperativeLGA - CREW REPORTED LEFT PACK FAILED WITH RIGHT PACK ON MEL. EMERGENCY DECLARED FLIGHT RETURNED LGA LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED BOTH SINGLE SEGMENT SWITCHES. SYSTEM GROUND CHECK NORMAL OPERATION.SDR AALA20120905002Frame · damagedELONGATED HOLE UNDER DOOR GUIDE AT STATION 1212 FROM LONGERONS 25 TO 24 RIGHT. INSTALLED REPAIR DOUBLER ON FRAME STATION 1212 PER EA MD80-53-025872.SDR AALA20120831007Skin · corrodedCORROSION ON INTERNAL SKIN FROM STATIONS 750 TO 760 AT LONGERONS 30 TO 29 LEFT AND RIGHT. INSTALLED DOUBLER PER SRM 53-04-03 FIGURE 11 SHEET 1 VIEW A.SDR AALA20120827019Cusp Web · crackedCUSP SHEET CRACKED AT FASTENER BETWEEN SEAT TRACKS NUMBERS 1 AND 2. INSTALLED DOUBLER REPAIR PER AARD 53-20-00-16.SDR AALA20120826004Skin · damagedLIGHTNING STRIKE TO FUSELAGE SKIN. INSTALLED DOUBLER PER SRM 53-04-02 FIGURE 2 SHEET 3 VIEW C.SDR AALA20120826003Skin · damagedLIGHTNING STRIKE TO FUSELAGE SKIN. INSTALLED DOUBLER PER SRM 53-04-02 FIGURE 2 SHEET 3 VIEW C.SDR AALA20120826002Skin · damagedLIGHTNING STRIKE TO FUSELAGE SKIN. INSTALLED DOUBLER PER SRM 53-04-02 FIGURE 2 SHEET 3 VIEW C.SDR AALA20120826005Pan · crackedLEFT FORWARD OVERWING EXIT DOOR PAN CRACKED AT UPPER AFT CORNER. DYE CHECKED AND STOP DRILLED CRACK. FABRICATED AND INSTALLED DOUBLER PER SRM 52-05-00 FIGURE 51.SDR AALA20120825009Longeron · crackedLONGERON 4 LEFT IS CRACKED AT STATION 218 IN THE RADIUS IN THE OUTBOARD LEG. INSTALLED LONGERON AND SPLICE AT LONGERON 4 STATION 218 PER SRM 53-02-00 FIGURE 18.SDR AALA20120824003Seat Track · corrodedNUMBER 5 SEAT TRACK AT STATION 200 CORRODED. ACCOMPLISHED STRAP REPAIR PER AARD 53-20-00-13.SDR AALA20120824001Skin · crackedCRACK IN RIGHT FUSELAGE SKIN AT STATION 1310 BETWEEN LONGERONS 6 AND 7 RIGHT. INSTALLED DOUBLER, FILLER AND FINGERS PER SRM 53-04-03 FIGURE 9 AND 51-01-00 PARAGRAPH 4.SDR AALA20120827001Skin · dentedDENT AT LEFT STATION 275 BETWEEN STRINGERS 23 AND 24 LEFT. INSTALLED INTERNAL DOUBLER PER SRM 53-04-02 FIGURE 02 SHEET 36.SDR AALA20120719017Charger · inoperativeFORWARD CABIN AND FLIGHT DECK EMERGENCY LIGHTS ARE INOPERATIVE. REPLACED BATTERY CHARGER FOR FORWARD EMERGENCY LIGHTS. OPS CHECK NORMAL.SDR AALA20110113DFW02Apu · malfunctionedDFW - CREW REPORTED AUXILIARY POWER UNIT FAILED ON TAKEOFF WITH LEFT GENERATOR ON PLACARD. EMERGENCY DECLARED FLIGHT RETURNED DFW LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. SHUTDOWN AND RESTARTED APU, RAN APU FOR 20 MINUTES NO FAULTS NOTED. RESDR AALA20091207TUL01Battery Pack · dischargedEMERGENCY LIGHT BATTERY PACK INOPERATIVE. REPLACED BATTERY PACK.SDR AALA20091204TUL07Skin · crackedFUSELAGE SKIN CRACKED AT CANT FRAME 1474. INSTALLED DOUBLER PER SRM 53-01-00 ON FUSELAGE AT STATION 1474.SDR AALA20091113LAX01Outflow Valve · failedAFTER TAKEOFF FLIGHT ATTENDANTS REPORTED FUMES IN THE CABIN. RETURNED TO LAX AND LANDED WITHOUT INCIDENT. REPLACED PRESSURE REGULATOR VALVE IN TAIL SECTION.SDR AALA20090723AUS01Detector · inoperativeAUS - RIGHT ENGINE WARNING INDICATION ILLUMINATED AFTER TAKEOFF. EMERGENCY DECLARED, RETURNED AUS WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED RIGHT ENGINE DETECTOR AMPLIFIER AND CAWS COMPUTER. SYSTEM GROUND CHECKED NORMAL OPERATIOSDR AALA200801337Pump · activatedATL INFLIGHT T2233/18MAY RSW TO STL. CENTER FORWARD FUEL BOOST PUMP POPPED CIRCUIT BREAKER. LANDED ATL WITHOUT INCIDENT. REPLACED CENTER FORWARD FUEL BOOST PUMP. SYSTEM GROUND CHECKED NORMAL OPERATION. (CLOSED) (A)SDR AALA200800458Battery Pack · inoperativeLGA - EMERGENCY LIGHTS AT FORWARD CABIN INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT FORWARD CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA200800457Battery Pack · looseLGA - EMERGENCY LIGHTS AT OVERHEAD SEAT ROWS 7 TO 16 INOPERATIVE. RESEATED BATTERY PACK FOR EMERGENCY LIGHTS AT OVERHEAD SEAT ROWS 7 TO 16. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20072321Slide · damagedMSP - EMERGENCY SLIDE AT LEFT NUMBER TWO DOOR HANDLE VELCRO MISSING. REPLACED SLIDE AT LEFT NUMBER TWO DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20070207Light · inoperativeLGA - FOUND EMERGENCY LIGHT AT AFT GALLEY SERVICE DOOR INOPERATIVE. REPLACED EMERGENCY LIGHT ASSEMBLY AT AFT GALLEY SERVICE DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.
Back to N487AA, cancelled Jun 5, 2021