N494AA, cancelled Feb 7, 2020
Service difficulty reports · 118
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N494AA' AND deregistration_id = 'N494AA-2020-02-07' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N494AA' AND deregistration_id = 'N494AA-2020-02-07' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201703079012Portable Light · inoperativeAIRCRAFT WAS NOT GROUNDED. L-1 CABIN EMERGENCY PORTABLE LIGHT IS INOPERATIVE. REMOVED AND REPLACED LIGHT IAW AMM 33-53-00. OPERATIONAL CHECK GOOD.SDR AALA20161224005B-Nut · leakingLOST OF RIGHT HYDRAULIC FLUID INDICATION. EMERGENCY DECLARED, AIRCRAFT WAS GROUNDED. LANDING UNEVENTFUL. SECURED LOOSE B-NUT ON HYDRAULIC LINE IN FORWARD RIGHT WHEEL WELL. SERVICED BOTH HYDRAULIC SYSTEMS. OPERATIONAL CHECKED GOOD.SDR AALA20160823003Battery Pack · dischargedFORWARD SECTION OF EMERGENCY LIGHTS ARE DIM. REMOVED AND REPLACED BATTERY PACK. FORWARD EMERGENCY LIGHTS OPS CHECKED OK.SDR AALA20160823002Battery Pack · dischargedAFT SECTION OF EMERGENCY LIGHTS ARE DIM. REMOVED AND REPLACED THE BATTERY PACK. LIGHTS OPS CHECKED OK.SDR AALA20160823001Battery Pack · inoperativeTAIL CONE EMERGENCY LIGHTS ARE INOPERATIVE. REMOVED AND REPLACED THE BATTERY MODULE. EMERGENCY LIGHTS OPS CHECKED NORMAL.SDR AALA20160406006Bearing · failedAIRCRAFT WAS GNDED. FLAMES REPORTED COMING FROM APU EXHAUST & SMOKE FROM APU INLET. NO FIRE WARNING OR INDICATION. SHUTDOWN APU. REPORTED TOTAL OIL QTY LOSS. FOUND TURBINE FAILURE DUE TO REAR BEARING FAILURE. R & R APU IAW MCM 49-96-82. ACCOMPLISHED OPERSDR AALA20151206003Pan · corrodedFORWARD CARGO DOOR PAN HAS CORROSION. R & R FWD CARGO DOOR PAN IAW SRM 53-05-00-001. ACFT IN BASE MX.SDR AALA20151204008Skin · corrodedFORWARD FUSELAGE SKIN BULGED & 7 EACH RIVET HEADS SHEARED OR CUPPED, BETWEEN L30R & L29R, AT PRODUCTION SPLICE, APPROX STATION 590. REMOVED CORROSION IAW SRM 51-10-03 & INSTALLED DOUBLER IAW 53-04-03 FIGURE 11. ACFT IN BASE MX.SDR AALA20151013001Battery Pack · dischargedAFT EMER LIGHTS CONTROLLED BY BATTERY PACK B5-28 INOPERATIVE. R & R B5-28 BATTERY PACK IAW AMM 33-53-00. AFFECTED AFT EMER LIGHT OPERATIONALLY CHECKED GOOD.SDR AALA20141123010B-Nut · looseEMERGENCY DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING DESCENT RT HYD SYS QTY INDICATED LOW & DECREASING. PERFORMED QRH & LANDED WITH RT HYD ENG & AUXILIARY PUMPS OFF. FOUND B NUT LEAKING AT LG MANIFOLD. TORQUED NUT IAW SP 20-30-02. PERFORMEDSDR AALA20140613008Coffeemaker · malfunctionedCREW REPORTED ELEC ODOR IN CABIN. CREW DONNED O2 MASKS FOR LANDING. EMER DECLARED FLIGHT LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. REPLACED FWD GALLEY NR 2 COFFEE MAKER THAT WAS CAUSING ODOR. SYS GND CHECKED NORMAL OPERATION CLOSED.SDR AALA20140611010Frame · crackedFRAME STATIONS FROM 1446 TO 1451 CRACKED. INSTALLED DOUBLER IAW SRM 51-70-5.SDR AALA20131014002Longeron · crackedLT LONGERON 24 UPPER FLANGE IS CRACKED AT STATION 160. INSTALLED LT 24 LONGERON SPLICE REPAIR AT STATION 160 IAW SRM 53-02-00.SDR AALA20131014011Longeron · crackedLONGERON 24 LT CRACKED AT STATION 160. INSTALLED LONGERON REPAIR AT STATION 160 IAW SRM 53-20-00.SDR AALA20121210004Skin · dentedDEEP DENT IN FUSELAGE SKIN AT STATION 436 BELOW LONGERON 21 LEFT. INSTALLED EXTERNAL DOUBLER PER SRM 53-04-03 FIGURE 1.SDR AALA20121208003Skin · dentedDENT WITH GOUGES AT FUSELAGE STATIONS 1186 LEFT AT LONGERON 19 LEFT. INSTALLED DOUBLER AND FILLER PER EA MD80-53-027475.SDR AALA20121207020Cusp Web · damagedLEFT CUSP INBOARD LIGHTNING HOLE AT STATION 1234 DAMAGED. INSTALLED DOUBLER REPAIR PER AARD 53-20-00-16.SDR AALA20121207019Cusp Web · damagedLEFT CUSP INBOARD LIGHTNING HOLE AT STATION 1238 DAMAGED. INSTALLED DOUBLER REPAIR PER AARD 53-20-00-16.SDR AALA20121207008Cusp Web · corrodedLEFT CUSP CORRODED FROM STATIONS 1174 TO 1176. INSTALLED DOUBLER PER SRM 53-05-00 FIGURE 131A-23.SDR AALA20121206012Bracket · corrodedCORROSION ON T BRACKET AT STA 1155 AT LONGERON 28 RIGHT. REPLACED BRACKET PER AARD 51-00-05-1.SDR AALA20121206011Web · corrodedCORROSION ON WEB FROM STATIONS 1149 TO 1220. REPLACED WEB PER AARD 51-00-05-1.SDR AALA20121206002Shear Tie · corrodedCORROSION ON FORWARD AND AFT SIDE OF SHEAR TIE AT STATION 1155 BETWEEN LONGERONS 30 LEFT AND 29 RIGHT. INSTALLED NEW SHEAR-TIE AT STATION 1155 PER AARD 51-00-05-1.SDR AALA20121206001Cusp Web · corrodedBOTTOM OF LEFT CUSP AT STATION 1164 IS CORRODED AT FASTNERS. INSTALLED CUSP REPAIR PER SRM 53-05-00 FIGURE 131A-23 AND EA MD80-53-027406.SDR AALA20121203023Skin · damagedLEFT ELEVATOR TOP SKIN HAS TWO DENTS LOCATED APPROXIMATELY 7 INCHES INBOARD OF STATION XET 26 AND 10 INCHES AFT OF LEADING EDGE OF ELEVATOR. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121203019Skin · dentedRIGHT ELEVATOR TOP SKIN HAS TWO DENT LOCATED APPROXIMATELY 150 INCHES FROM INBOARD END AND 10 INCHES FROM TRAILING EDGE OF ELEVATOR. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121203018Skin · dentedLEFT ELEVATOR TOP SKIN HAS TWO DENTS LOCATED APPROXIMATELY 70 INCHES FROM INBOARD EDGE AND 5 INCHES UP FROM TRAILING EDGE. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121203017Skin · dentedLEFT ELEVATOR TOP SKIN HAS THREE DENTS LOCATED APPROXIMATELY 19 INCHES OUTBOARD OF STATION XET 80 AND 8 TO 14 INCHES FORWARD OF TRAILING EDGE. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121203004Skin · damagedLEFT ELEVATOR TOP SKIN HAS THREE DENTS LOCATED APPROXIMATELY 34 INCHES INBOARD OF STATION 173 AND 5 INCHES FORWARD OF TRAILING EDGE OF ELEVATOR. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121203003Structure · damagedLEFT ELEVATOR 4 DENTS LOCATED APPROXIMATELY 3 TO 5 INCHES INBOARD OF STATION XET 80 AND 9 TO 14 INCHES FORWARD OF TRAILING EDGE. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121203002Structure · damagedLEFT ELEVATOR 3 DENTS LOCATED APPROXIMATELY 3 INCHES OUTBOARD OF STATION XET 46 AND 3 INCHES FORWARD OF TRAILING EDGE. INSTALLED REPAIR DOUBLER PER SRM 51-70-06.SDR AALA20121202007Skin · dentedLEFT ELEVATOR TOP SKIN HAS TWO DENTS LOCATED APPROXIMATELY 2 INCHES OUTBOARD OF STATION XET 65 AND 11 INCHES FORWARD OF TRAILING EDGE OF ELEVATOR. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121202006Skin · dentedLEFT ELEVATOR TOP SKIN HAS THREE DENTS LOCATED APPROXIMATELY 10 INCHES OUTBOARD OF STATION XET 46 AND 9 INCHES FORWARD OF TRAILING EDGE OF ELEVATOR. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121203007Structure · dentedLEFT ELEVATOR 4 DENTS LOCATED APPROXIMATELY 5 INCHES INBOARD OF STATION XET 80 AND 9 TO 14 INCHES FORWARD OF TRAILING EDGE. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121206006Skin · dentedLEFT ELEVATOR TOP SKIN HAS TWO DENTS LOCATED APPROXIMATELY 7 INCHES OUTBOARD OF STATION XET 26 AND 10 INCHES FORWARD OF TRAILING EDGE. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121206005Skin · damagedLEFT ELEVATOR TOP SKIN HAS TWO DENTS LOCATED APPROXIMATELY 2 INCHES OUTBOARD OF STATION XET 26 AND 7 INCHES FORWARD OF TRAILING EDGE. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121203016Skin · dentedLEFT ELEVATOR TOP SKIN HAS MANY DENTS LOCATED APPROXIMATELY 3 INCHES OUTBOARD OF STATION XET 26 AND 19 INCHES AFT OF LEADING EDGE. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121203012Skin · dentedLEFT ELEVATOR TOP SKIN HAS 2 DENTS 32 INCHES OUTBOARD OF STATION XET 80 AND 3 INCHES FORWARD OF TRAILING EDGE. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121205009Skin · dentedRIGHT ELEVATOR TOP SKIN HAS DENTS LOCATED APPROXIMATELY 136 INCHES FROM INBOARD EDGE AND 6 INCHES UP FROM TRAILING EDGE. INSTALLED REPAIR DOUBLER PER SRM 51-70-06.SDR AALA20121205008Structure · dentedDENTS 46 INCHES OUTBOARD OF STATION XTE 173 AND FORWARD OF TRAILING EDGE. INSTALLED DOUBLER ON ELEVATOR PER SRM 51-70-06.SDR AALA20121203009Structure · dentedLEFT ELEVATOR HAS 2 DENTS 35 INCHES OUTBOARD OF STATION XET 80 AND 8 INCHES FORWARD OF TRAILING EDGE. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121203006Skin · dentedLEFT ELEVATOR TOP SKIN HAS THREE DENTS LOCATED APPROXIMATELY 10 INCHES OUTBOARD OF STATION XET 46 AND 9 INCHES FORWARD OF TRAILING EDGE OF ELEVATOR. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121130022Skin · damagedRIGHT ELEVATOR TOP SKIN HAS DENTS LOCATED APPROXIMATELY 130 INCHES FROM INBOARD END AND 10 INCHES UP FROM TRAILING EDGE. INSTALLED REPAIR DOUBLER PER SRM 51-70-06.SDR AALA20121130015Skin · dentedRIGHT ELEVATOR TOP SKIN HAS DENTS APPROXIMATELY 32 INCHES FROM INBOARD EDGE AND UP 5 INCHES FROM TRAILING EDGE. INSTALLED REPAIR DOUBLER PER SRM 51-70-06.SDR AALA20121130014Skin · dentedRIGHT ELEVATOR TOP SKIN HAS 3 DENTS APPROXIMATELY 45 INCHES FROM INBOARD END AND 7 INCHES FROM TRAILING EDGE OF ELEVATOR. INSTALLED REPAIR DOUBLER PER SRM 51-70-06.SDR AALA20121130013Structure · damagedDENTS APPROXIMATELY 28 INCHES FROM INBOARD EDGE AND 20 INCHES FROM TRAILING EDGE. INSTALLED DOUBLER ON RIGHT ELEVATOR SRM 51-70-06.SDR AALA20121130006Structure · damagedDENTS 30 INCHES INBOARD OF STATION XET 26 AND 9 INCHES FORWARD OF TRAILING EDGE. INSTALLED DOUBLER ON ELEVATOR PER SRM 51-70-06.SDR AALA20121203008Skin · dentedLEFT ELEVATOR TOP SKIN HAS 2 DENTS LOCATED APPROXIMATELY 2 INCHES OUTBOARD OF STATION XET 65 AND 11 INCHES FORWARD OF TRAILING EDGE. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121129029Intercostal · crackedCEILING INTERCOSTAL CRACKED AT STATION 774, CENTER. INSTALLED NEW INTERCOSTAL PER AARD 51-00-05-1.SDR AALA20121203011Skin · dentedLEFT ELEVATOR TOP SKIN HAS 3 DENTS LOCATED APPROXIMATLEY 34 INCHES INBOARD OF STATION XET 173 AND 56 INCHES FORWARD OF TRAILING EDGE OF ELEVATOR. INSTALLED DOUBLER PER SRM 51-70-06.SDR AALA20121203010Structure · dentedLEFT ELEVATOR HAS 3 DENTS LOCATED APPROXIMATELY 34 INCHES OUTBOARD OF STATION XET 80 AND 9 INCHES FORWARD OF TRAILING EDGE. INSTALLED DOUBLER PER SRM 51-70-06.