N522NK, cancelled Jun 15, 2024
Service difficulty reports · 186
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N522NK' AND deregistration_id = 'N522NK-2024-06-15' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N522NK' AND deregistration_id = 'N522NK-2024-06-15' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2024040238036Bottle · low pressureR1 DOOR ASSIST BOTTLE PRESSURE LOW-SERVICE R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00. NO FURTHER DEFECT NOTED.SDR GTIA2023072437349Unknown · unknownDRY OIL SMELL ON DESCENT IN COCKPIT. -PREFORMED TSM 05-50-00-810-831-A. FOUND APU CENTER DRAIN LEAKING./ PACK 1 CONTAMINATED. REF LOGPAGE 3319363-2 AND LOGPAGE 3319364-1 FOR DEFERALS.SDR GTIA2023061937271Megaphone · inoperativeDURING SERVICE CHECK FOUND L1 DOOR MEGAPHONE INOP-R/R L1 DOOR MEGAPHONE IAW AMM 25-65-00 OPS CHECKS GOODSDR GTIA2022120136810Door Seal · damagedCAB ALT WARNING LAST NOTED CABACT 10,800-R/R AFT CARGO DOOR SEAL IAW AMM 52-32-18, OPS CHECK GOOD. ALSO PERFORMED LEAK CHECK IAW AMM 05-53-00, LEAK CHECK GOOD.SDR GTIA2022112936805Bottle · low pressureDURING WEEKLY FOUND R1 DOOR ASSIST LOW PRESSURE-SVC'D R1 DOOR ASSIST BOTTLE TO APPROPRIATE PRESSURE IAW AMM 52-10-00.SDR GTIA2022110736764A/C Pack · odorDURING DESCENT TO APPROACH PHASE STRONG WET SOCK OR DIRTY SOCK ODOR WAS FELT IN THE FLIGHT DECK AFTER FOLLOWING THE QRM PRODEDURES # 1 PACK WAS TURED OFF AND THE ODOR STOP-ISOLATED PACK 1 PERFORMED TSM 05-30-00-810-831-ASDR GTIA2022110136752Bottle · dischargedR1 DOOR ASSIST BOTTLE LOW-SERVICED R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00-602SDR GTIA2022091536662None · nonePASSENGER /CREW DOOR R'1' ASSIST BOTTLE NEEDS SERVICING. -SERVICED PASSENGER /CREW DOOR R '1' TO THE REQUIRED PSI IAW AMM 52-10-00.SDR GTIA2022082636619None · noneR1 DOOR ASSIST BOTTLE NEEDS SERVICING-SERVICED R1 DOOR ASSIST BOTTLE TO PROPER LEVEL IAW AMM 52-10-00.SDR GTIA2022051236419None · noneFAINT SOAPY CHEMICAL SMELL ON DECENT FROM 4000-3000 SMELLED IN COCKPIT SHUT PACK 1 OFF SMELL WENT AWAY ( PACKS A319 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - AT OR BELOW FL 370 )--SDR GTIA2022030736309Not Reported · not reportedR1 DOOR ASSIST BOTTLE REQUIRES SERVICING -SERVICED R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2022013136245Not Reported · not reportedFWD GALLEY MEGAPHONE INOP-R/R FWD GALLEY MEGAPHONE IAW AMM 25-65-51.SDR GTIA202201316249Megaphone · inoperativeFWD GALLEY MEGAPHONE INOP-R/R FWD GALLEY MEGAPHONE IAW AMM 25-65-51.SDR GTIA2021102836072None · noneR1 DOOR ASSIST BOTTLE PRESSURE IS LOW-SERVICED R1 DOOR BOTTLE TO 1600 PSI IAW AMM 52-10-00SDR GTIA2021080935921Bottle · low pressureR1 DOOR ASSIST BOTTLE REQUIRED SERVICE.-SERVICED R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2021071935882Bottle · low pressureR1 DOOR EMER ASSIST BOTTLE REQ SERVICING -SERVICED R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2021071235867Bottle · low pressureR1 DOOR ASSIST ACCUMULATOR LOW-SERVICED R1 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-10-00.SDR GTIA2021062835826Bottle · low pressureR1 DOOR ASSIST ACCUMULATOR LOW-SERVICED R1 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-10-00SDR GTIA2021052035751Megaphone · brokenFWD MEGAPHONE BROKEN-REMOVED AND REPLAACED FWD MEGAPHONE IAW AMM 25-65-61.SDR GTIA2021051335735Bottle · low pressureDOOR ASSIST BOTTLE REQUIRES SERVICING R1 DOOR-SERVICED R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2021050335710Unknown · odorFA STATES STRONG FULL ODOR IN FWD GALLEY & ROW 1. NO ODOR NOTED IN COCKPIT.-PERFORMED IDENTIFICATION OF CABIN ODPRS TSM 05-50-00-810-831-A ISOLATION OF ALL SYSTEMS COULD NOT DUPLICATE ANY ODOR AT THIS TIME.SDR GTIA2021032235647Bottle · low pressureR1 DOOR ASSIST ACCUMULATOR LOW-SERVICED R1 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-10-00SDR GTIA2021031235635Bottle · low pressureR1 DOOR ASSIST BOTTLE REQ SVC-SVC R1 DOOR ASSIST BOTTLE TO PROPER PRESSURE AS PER AMM 52-10-00SDR GTIA2021021135592Bottle · low pressureR1 DOOR ASSIST ACCUMULATOR-SERVICED R1 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-10-00SDR GTIA2021020435584Megaphone · brokenDURING WEEKLY CHECK FOUND AFT MEGAPHONE BROKEN-R & R AFT MEGAPHONE IAW SPIRIT AIRLINES EMERGENCY EQUIPMENT LAYOUT NK317-132-EQ, OPS CHECK NORMALSDR GTIA2021012535563Bottle · low pressureR1 DOOR ASSIST ACCUMULATOR LOW. SERVICED R1 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE, IAW AMM 52-6-00.SDR GTIA2020122135506Bottle · low pressureR2 DOOR ASSIT BOTTLE LOW PRESS. SERVICED R2 ASSIT BOTTLE, IAW AMM 52-10-00.SDR GTIA2020111235441Bottle · low pressureR1 DOOR ASSISST BOTTLE NEED SERVICE. SERVICED R1 DOOR ASSISST BOTTLE, IAW AMM 52-10-00-614-001.SDR GTIA2020052645186Toilet · inoperativeAFT LAV INOP SUCTION DOES NOT STOP/CONSTANT FLUSH-R/R AFT LAV TOILET ASSY IAW AMM 38-31-41. OPS + LEAK CHECK GOODSDR GTIA2020051435173A/C Pack · odorFUME EVENT AFTER T/O/ DIRTY SOCK SMELL. ISOLATED PACK 1 AND SMELL WENT AWAY. I CRUISE TURNED PACK 1 ON AND NO SMELL. ODOR RETURNED ON DECENT ISLOALTED PACK 1 AND LEFT IT OFF-REF TSM 05-50-00-810-831-A. PERFORMED PACK BURN OUT. NO ODOR, SMOKE, OR FUME PRESENT SDR GTIA2020032335118Seal · damagedDIRTY SOCK SMELL ON DESCENT THROUGH 4000: PACK 2 ISOLATED AND SMELL DISSAPATED-ACCOMPLISHED AMM 21-00-00-615-803-A LEVEL B. DECONTAMINATION OF ECS. REMOVED, INSPECTED AND REINSTALLED ENG 1 AND 2 PRV IAW AMM 36-11-52. NO DEFECTS NOTED. REMOVED, INSPECTED AND RESDR GTIA2020032335116Filter · odorDURING DESCENT THROUGH FL 210 DIRTY SOCKS SMELL PACK 1 WAS OFF APU WAS OFF-PERFORMED DECONTAMINATION OF THE ECS SYSTEM IAW AMM 21-00-00. R&R THE RECIRCULATION FILTERS IAW AMM 21-21-41. NO FURTHER SMELLS NOTED AFTER DECONTAMINATION. A/C OK FOR SERVICE.SDR GTIA2020032335112Apu · leakingDURING DESCENT THROUGH 18,000' DIRTY SOCK SMELL IN COCKPIT FOR BRIEF TIME, LESS THAN 1 MIN-REF LP #2583588-1 FOR CORRECTIVE ACTION FOR APU OIL LEAK. PERFORMED PACK BURN IAW AMM 21-00-00. NO ODORS AT THIS TIME. PACK 1 OK FOR SERVICESDR GTIA2020032335111A/C Pack · odorON FINAL APPROACH( @ 3000 FT) DIRTY SOCK SMELL IN COCKPIT AND CABIN PERFORMED AOM PROC, PACK 1 OFF X BLEED SHUT SMELL DISSAPATED-PERFORMED TSM 05-50-00-810-831-A ODOR FOUND TO BE IN PACK 1. SEE LOG PAGE 258359102 FOR DEFFERAL OF PACK 1SDR GTIA2020031935106Unknown · odorDURING DESCENT THROUGH 8000 IN CLOUDS FA REPORTED FOUL SMELL IN CABIN WE TURNED OFF PACK 2, SMELL WENT AWAY-PERFORMED TSM 05-50-00-810-813-A NO LEAK FOUND ON ENG #1 OR 2 AND APUSDR GTIA2020021035003Bottle · low pressureR1 DOOR ASSIST BOTTLE REQ SERVICE-SERVICED R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2020010934925Bottle · low pressureR2 DOOR ASSIST BOTTLE NEED SERVICING-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00. NO LEAK DETECTED AT THIS TIMESDR GTIA2019122644895Unknown · odorDESCENDING OUT OF 5000FT WE DETECTED FUMES IN THE COCKPIT RAN COM 3.226 AND SUSPECTED PACK 1 THE SMELL DID NOT GO AWAY SO WE ISOLATED PACK 2 AND THE SMELL DISIPUTED. -ISOLATED ALL BLEED AIR IAW TSM 05-50-00-810-831, NO ODOR NOTED PREFROMED ENG RUN WITH ENG BLSDR GTIA2019122634892Unknown · odorDESCENDING OUT OF 5000 FT, A SMELL WHAT WAS A SUSPECTED FUME EVENT FOLLOWED COM 3.226 UPON SHUTTING OFF PACK 2 THE SMELL SEEMED TO DISSIPATE. R & R NR 1 ENG AND 2 DEOILER SEALS IAW AMM 72-60-31. OPS CHECKED GOOD. R & R THE NR 1 AND 2 RECIRCULATION FILTER IAWSDR GTIA2019120534837Bottle · low pressureR1 DOOR ASSIST BOTTLE REQ SVC-SVCD R1 DOOR ASSIST BOTTLE PER AMM 52-10-00SDR GTIA2019112934825Flashlight · inoperativeR2 FLASHLIGHT INOP-R/R R2 FLASHLIGHT IAW NK312-2132 EMER EQUIP LAYOUTSDR GTIA2019102854731Unknown · odorMUSTY ODOR ON DECENT IN COCKPIT ONLY TURNED OFF PACK 1 AND IT IMPROVED CABIN ODOR FORM COMPLETED ( PACKS A319 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - AT OR BELOW FL 370 )-PERFORMED TSM 05-50-00810-831-A, TYPE 5. SDR GTIA2019091634630Megaphone · damagedAFT MEGAPHONE DAMAGED. R&R AFT MEGAPHONE IAW CMM 25-60-01. OPS CHECK GOOD OK FOR SERVICE AT THIS TIME.SDR GTIA2019090334595Acm · odorINTERMITTANT SMELL OF BURNT MATCHES ON FLIGHT DECK ON DECENT. REF LOG PAGE 2501168-2 FOR R&R OF #1 PACK ACM IAW AMM 21-52-21 OCKS AND LEAK CHECKS GOOD NO BURNT SMELLS NOTED AT THIS TIME.SDR GTIA2019082243562Megaphone · inoperativeMEGAPHONE R2 DOOR INOP. REMOVED AND REPLACED AFT MEGAPHONE PER AMM 25-65-51.SDR GTIA2019081984560A/C Pack · odorPACK 1 DESELECTED DUE TO FUME/ODOR. PACK 1 RESELECTED & SMOKE BECAME PRESENT IN COCKPIT.SDR GTIA2019061083399A/C Pack · odorODOR ON DESCENT-ACCOMPLISHED TSM 05-50-00-810-831-A, FOUND #2 PACK HAS ODOR. REF LP 2475157 ITEM 2 FOR ACTIONSDR GTIA2019042533303Ecs · contaminatedODOR SMELLED ON DESCENT THRU 4000FT. FUMES PROCEDURED PROTORMEL AND ODOR DISSIPATED. PACK 1 OFF. PERFORMED DECONTANMINATION OF THE ENVIROMENTAL CONTROL SYS PER AMM 21-00-00. NO DEFECTS OR ODORS NOTED. SYS CHK OK.SDR GTIA201904223295Unknown · odorFUMES DETECTED IN COCKPIT AND CABIN ON DESCENT FROM FL 260 TO GND FUME ELIMINATION WAS EMPLOYED AND SEEMED TO DISSIPATE FROM COCKPIT WHEN PACK 1 OFF . -PERFORMED TSM 05-50-00-810-831-A IAW DECISSION TABLE PERFORMED TSM 05-50-00-810-085-B TYPE 2 AND TYPE 3 REF SDR GTIA2019041603287Unknown · odorF/A REPORTS AN ODER (INTERMITTANT) SIMILAR TO RUBBER IN R2 JUMPSEAT & ROW 25/26 ONLY-PERFORMED TSM TAK 05-50-00-810-831-A TO DETERMINE CAUSE OF HIGHLY LOCALIZED RUBBER SMELL. NO ODOR PRESENT ON ARRIVAL ENG QTY NORMAL; PACK CIRCULATION NORMAL; AREAS AROUND ROWS