N529NK, cancelled Nov 14, 2024
Service difficulty reports · 114
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N529NK' AND deregistration_id = 'N529NK-2024-11-14' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N529NK' AND deregistration_id = 'N529NK-2024-11-14' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2024100738414Bottle · low pressureR2 DOOR ASSIST BOTTLE NEEDS SERVICING -SERVICED R2 DOOR BOTTLE IAW AMM 52-10-00SDR GTIA2024091738368Bottle · low pressureL2 DOOR ASSIST BOTTLE NEEDS SVC-SERVICED L2 DOOR ASSIST BOTTLE PER AMM 52-10-00SDR GTIA2024041438065A/C Pack · odorHAD FUME EVENT AFTER TAKE OFF, TURNED PACK 1 OFF SMELL WENT AWAY. THE SMELL WAS MILD AND CONSISTENT. APU AND APU BLEED WAS OFF.-PERFORMED TSM 05-50-00-810-813-A, RUN BOTH ENG'S AND APU, FOUND ONLY PACK #1 TO BE CONTAMINATED, REFER TO NEXT LOGBOOK PAGE FOR PACKSDR GTIA2024032638024Unknown · odorOIL SMELL ON TAKE OFF WENT AWAY SHUTTING ALL PACK 1, PACK 2 SMELLED BAD ON DESCENT PACK 2 ALSO SHUTDOWN--SDR GTIA2023122237712Unknown · unknownON FINAL DESCENT DIRTY SOCK SMELL AFTER PROCEDURE WAS COMPLETE IT SEEMS LIKE IT CAME FROM PACK #2-PERFORMED PACK BURNOUT IAW AMM 21-00-00-615-004. OPS CHECKS GOOD, NO DEFECTS NOTED AT THIS TIME. A/C OK FOR CONTINUED SERVICESDR GTIA2023102437556Unknown · unknownR1 AND L2 DOOR ASSIST BOTTLE REQ. SVC.-R1 AND L2 DOOR ASSIST BOTTLE SVCD IAW A319 AMM 52-10-00.SDR GTIA2023031637047O-Ring · leakingDURING FLIGHT LOST YELLOW SYSTEM HYDROLIC SYSTEM FLUID PERFORMED ECAM ACTION AND COME FOR LOSS OF YELLOW SYSTEM FLUID (YELLOW FLUID VERY LOW)-FOUND UNION 3093GM LEAKING. R/R O-RING IAW AMM 29-13-15. OPS CHECK / LEAK CHECK GOOD. NO FURTHER DEFECTS NOTEDSDR GTIA2022110136751Bottle · dischargedL2 & R2 DOOR ASSIST BOTTLES UNDERPRESSURE. -SERVICED L2 & R2 DOOR ASSIST BOTTLES IAW AMM 52-10-00-614-001.SDR GTIA2022102136726Megaphone · inoperativeAFT FLIGHT ATTENDANT MEGAPHONE INOP.-R & R AFT FLIGHT ATTENDANT MEGAPHONE IAW AMM 25-65-51. OPS CHECK GOOD.SDR GTIA2022091936668None · noneL2 DOOR ASSIT BOTTLE REQ SERVICE-SERVICED L2 DOOR ASSIT BOTTLE IAW AMM 52-10-00. OPS CHECK GOOD NO LEAKS NOTED.SDR GTIA2022090236632None · noneL2 ASSIST BOTTLE REQUIRES NITROGEN SERVICE-SERVOCE L2 DOOR ASSIST BOTTLE IAW AMM 52-22-00SDR GTIA2022083036626None · noneAFT GALLEY MEGPHONE INOP-R&R AFT GALEEY MEGAPHONE IAW A319 AIRCRAFT DRAWINGSSDR GTIA2022071136523None · none"L2 DOOR ASSIT REQ SERVICE -SERVICED L2 DOOR IAW AMM 52-10-00
T/W NK791 CAL DUE 2/23
GAUGE NK2643 CAL DUE 2/23"SDR GTIA2022071136522None · none"R1 DOOR ASSIT REQ SERVICE -SERVICED R1 DOOR IAW AMM 52-10-00
T/W NK791 CAL DUE 2/23
GAUGE NK2643 CAL DUE 2/23"SDR GTIA2022070136503None · noneL2 DOOR ASSIST BOTTLE NEEDS SERVICING-SVCD. L2 DOOR ASSIST BOTTLE. IAW AMM: 52-10-00SDR GTIA2022022136292Not Reported · not reportedL2 DOOR ASSIST BOTTLE NEEDS SERVICING.-SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2022021436274Not Reported · not reportedPER WEEKLY R1 AND R2 DOOR REQ EMER., ASSIST BOTTLE SERVICE.-SERVICE R1 AND R2 DOOR EMER. ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2022020736259Not Reported · not reportedR1 AND L2 ASSIST BOTTLE DOOR REQUIRES SERVICE.-SERVICED R1 AND L2 DOOR ASSIST BOTTLE TO PROPER LEVEL IAW AMM 52-22-00SDR GTIA2021111136111Unknown · odorFUME EVENT BETWEEN 5000' - 3000' STRONGST SMELL NEAR EXIT ROW SMELLED IN FLIGHT DECK AND IN CABIN-REF TSM 5-50-00 APU VERIFIED NO LEAKS PRECONDITIONAL AC WITH APU NO SMELL NOTED ISOLATED PACK 1 & 2 NO SMELL NOTED AC OK FOR SERVICE IAW AMM 21-61-00 & 49-00-00.SDR GTIA2021111136108Skin · dentedDENT / CRACK FOUND ON FUSELAGE SKIN AT FR. 23+8" STR 41L+4" RAF-01 OPENED.-REPAIRED DENT ON FUSELAGE SKIN FR 23+8" STR 41+4" LH IAW A319 SRM 53-11-11-300-052. REQUIRES RE-INSPECT AT 60,000 FC, 120,000 FH. SUBSEQUENT INSPECT TBD IAW A319 SRM 53-11-11-205-051.SDR GTIA2021090335968Bottle · low pressureL1,L2 & R3 DOORS ASSIST BOTTLES REQUIRE SERVICING.-SERVICED L1,L2 & R1 DOOR ASSIST BOTTLES IAW AMM 52-10-00SDR GTIA2021072235884Bottle · low pressureDOOR ASSIST BOTTLES REQUIRE SERVICE L1, L2-SERVICE L1 AND L2 DOOR ASSIST BOTTLE PER AMM 52-10-00 LEAJ CHECK GOOD.SDR GTIA2020092435366Bottle · low pressureDOOR ASSIST BOTTLES AT L1, L2, R1, R2 REQUIRE SERVICING. SERVICED L1, L2, R1, R2 DOOR ASSIST BOTTLES, IAW AMM 52-10-00.SDR GTIA2020071635263Bottle · low pressureL1 DOOR DOOR ASSIST BOTTLE PRESS IS LOW. SERVICE DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2020022745045Bottle · low pressureL1 DOOR ASSIST REQUIRES SVC-SERVICED L1 DOOR ASSIST IAW AMM 52-10-00SDR GTIA2020011134932Fan · faultyELECTRIC FUMES IN COCKPIT CABIN WITH VENT EXHUAST ECAM AND AVIONICS VENT EXTRACT CIRCUIT BREAKER POPPED-APPLIED TSM 21-26-00-810-810-A. DURING OPS CHECK EXTRACT FAN (18HQ) MAKING LOUD NOISE. R&R EXTRACT FAN (18HQ) IAW AMM 21-26-51. OPS CHECK GOOD. NO SMELL NOSDR GTIA2019120534838Bottle · low pressureL1 & L2 DOOR ASSIST NEED SERVICED-SERVICED L1 & L2 DOOR ASSIST BOTTLES IAW AMM 52-55-00SDR GTIA2019111434783Bottle · low pressureL1 DOOR ASSIST BOTTLE REQ'D SVC-SVCD L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2019092134640Megaphone · defectiveAFT FA BULLHORN TRANSMIT BUTTON WILL NOT RELEASE. REMOVED AND REPLACED AFT FA MEGAPHONE IAW AMM 25-65-51. OK FOR SERVICE.SDR GTIA2019091834632Bottle · low pressureL2 DOOR ASSIST REQUIRES SERVICE. SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-0-614-001 LEAK CHECK GOOD.SDR GTIA2019091534625Flashlight · inoperativeREF DMI # 250810801 F/O FLASHLIGHT INOP. R/R FLASHLIGHT PER EMERGENCY EQUIPTMENT. THIS CLEARS DMI # 250810801, MOC NOTIFIED.SDR GTIA2019090634597Bottle · lowL1 DOOR BOTTLE ASSISTANCE REQUIRE SERVICE. SERVICE L1 DOOR BOTTLE ASSISTANCE TO PROPER LEVEL IAW AMM 52-10-00. OPS CHECK GOOD. NO LEAKS AT THIS MOMENT.SDR GTIA2019083034585Bottle · low pressureL1 DOOR ASSIST BOTTLE LOW-SERVICED L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00. LEAK CHECK GOODSDR GTIA2019083034584Bottle · low pressureL2 DOOR ASSIST BOTTLE LOW-SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2019080524524Bottle · low pressureL1 DOOR ASSIST BOTTLE LOW PRESSURE-SERVICED L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00. LEAK CHECK GOODSDR GTIA2019072003492Bottle · low pressureL1 AND L2 DOOR ASSIST BOTTLES NEED SERVICNG. SERVICED L1 & L2 DOOR ASSIST BOTTLES IAW AMM 52-10-00. LEAK AND OPS CHECK GOOD.SDR GTIA2019070703462Bottle · low pressureFWD LT DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED FWD LT DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001.SDR GTIA2019040853267Megaphone · inoperativeAFT MEGAPHONE NOT WORKING -REMOVED AND REPLACED AFT F/A'S MEGAPHONE PER DRAWING A319-EMER-EQIP A/C OK FOR SERVICESDR GTIA2019031703219Flashlight · inoperativeREF DMI # 2384962-2 "FO FLASHLIGHT INOP". R/R FO FLASHLIGHT IAW EMERGENCY EQUIPMENT LAYOUT. THIS CLEARS DMI # 2384962-2. PLACARD REMOVED & MOC NOTIFIED. DMI LOG PAGE IS UPDATED.SDR GTIA2018110202939Box Beam · distortedFRAME 43 SIDE BOX BEAM DISTORTED.SDR GTIA2018110202938Skin · chafedRIGHT ENGINE NOSE COWL CHAFED .SDR GTIA2018110202937Frame · crackedFRAME 16 CRACKED AT DOUBLE JOGGLE. REPAIRED IAW RDAS 80528626-005.SDR GTIA2018110202936Window Frame · crackedCRACK FOUND ON WINDOW FRAME 4.SDR GTIA2018092402853Fastener · missingAFT LEFT EMERGENCY FLASHLIGHT MISSING HARDWARE. R&R AFT LEFT EMERGENCY FLASHLIGHT IAW CMM 25-60-02.SDR GTIA2018090202825Unknown · odorDIRTY SOCK SMELL DURING DECENT BELOW 10000 ISOLATED TO ENG 2 BLEED. PERFORMED TSM 02-50-00-810-831-A ISOLATED SMELL TO ENG 2 BLEED SEE ITEM 234709601 FOR CORRECTIVE ACTION AIRCRAFT OK FOR CONT SERVICE.SDR GTIA2018082322811Bottle · low pressureL1 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA201808202806Bottle · low pressureL1 DOOR ASSIST ACCUMULATOR HAD LOW PRESSURE, SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2018032202536Bottle · low pressureL1 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE BOTTLE IAW AMM 52-10-00. LEAK CHECKED GOOD.SDR GTIA2018021902447Unknown · odorSTRONG ODOR OUT OF 10,000 FT. IAW TSM 05-50-00810-831-A PERFORMED. VISUAL CHECKS OF RELATED COMPONENTS IAW STEP 9 OF TSM. NO FAULTS NOTED. NO ODOR PRESENT. ACFT OK FOR CONTINUED SERVICESDR GTIA2017121802294Unknown · unknownLOUD WHISTLE SOUND IN COCKPIT DURING FLIGHT, APPEARS TO COME FROM OVERHEAD JUST FWD OF COCKPIT DOOR. PERFORMED AN INSPECTION OF ALL COCKPIT WINDOW SEALS NO DEFECTS NOTED. LUBRICATED THE SLIDING WINDOWS IAW AMM 56-12-11
Back to N529NK, cancelled Nov 14, 2024