N5793Y, cancelled Apr 15, 1996
Service difficulty reports · 16
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N5793Y' AND deregistration_id = 'N5793Y-1996-04-15' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N5793Y' AND deregistration_id = 'N5793Y-1996-04-15' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HEEA966766Transmitter · defectiveCONTACTS OPEN FROM 1.2 TO 1.4 BARS THEN CLOSES.SDR HEEA966700Indicator · erraticT4 INDICATOR NEEDLE HAS A ERRATIC INDICATION. TIME SINCE REPAIR 0:00.SDR HEEA966654Elec. Box · defectiveR/H GENERATOR WILL NOT COME ON LINE.SDR HEEA966611Indicator · errorCHECKED INDICATOR USING BARFIELD T-1000 AND FOUND INDICATOR 40 DEGREES OFF. INDICATOR COULD NOT BE ADJUSTED. ADJUSTMENT SCREW IS STRIPPED OUT AND PUSHED IN.SDR HEEA956252Indicator · reads lowINDICATOR READS LOW AT 800 DEGREES AND CRACKED SEAL.SDR HEEA956237Elt · inoperativeELT G SWITCH INOPERATIVE.SDR HEEA955833Starflex · bushing wornSTARFLEX THREE ARM BUSHINGS WORN BEYOND LIMITS.SDR HEEA955480Tube Assy · making metalENGINE REMOVED DUE TO METAL IN OIL. UPON INSPECTION OF GEARBOX PARTS NOTED THE FOLLOWING: BELOW CEB1307 REQUIREMENTS ON TUBE ASSEMBLY. INSTALLED NEW TUBE ASSY. PART RETURNED TO ALLISON FOR CEB1307. REFERENCE: AFA#24405A (PART IS OUT OF CALENDAR DATE AND SDR HEEA955378Bleed Valve · defective#1 ENGINE COMPRESSOR SURGES WITH THROTTLE APPLICATION. REPLACED BLEED VALVE AND RETURNED TO SERVICE.SDR HEEA955258Sensor Assy · defectiveSENSOR READS HIGH OUT OF TOLERANCE.SDR HEEA955255Sensor Assy · defectiveUNIT TRANSMITS LOW OUT OF TOLERANCE.SDR HEEA954756Transmitter · intermittentTRANSMITTER FLUCTUATES AND WORKS INTERMITTENTLY.SDR HEEA954730Transmitter · failedTRANSMITTER OUTPUT READS ZERO. TIME SINCE REPAIR 42:00.SDR HEEA954473Indicator · stuckNEEDLE STUCK AT 20MPH. TIME SINCE REPAIR 19:50.SDR HEEA954377Sensor Assy · malfunction#2 AUTO RELIGHT COMES ON INTERMITTENTLY DURING FLIGHT. REPLACED WITH SERVICEABLE TRANSDUCER.SDR HEEA954254Transmitter · defectiveNO OUTPUT. TIME SINCE REPAIR 31:10.