N580HA, cancelled Feb 21, 2019
Service difficulty reports · 280
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N580HA' AND deregistration_id = 'N580HA-2019-02-21' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N580HA' AND deregistration_id = 'N580HA-2019-02-21' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HALA2016070300268Slide · low pressureF/A'S REPORT, SLIDE PRESSURE AT 2R DOOR IS IN THE RED, ON THE LINE AT DEPARTURE. R & R 2R DOOR SLIDE IAW AMM 25-66-01-404-072. OPS AND SECURITY CHECK GOOD. OK FOR SERVICE.SDR HALA2016062700254O-Ring · damagedAIR DIVERSION, RT HYD QUANTITY INDICATOR, INDICATED DECREASING TO .78 TURNED RT ENGINE PUMP, ELEC PUMP OFF, DECREASING QUANTITY STOPPED. ON ARRIVAL, FOUND QTY AT 0.98, SERVICED SYS TO 1.09. LEAK CHECKED RUDDER & ELEVATOR PCA'S, DEPLOYED SPOILERS, OPERATED FLSDR HALA2016042700143Fan · contaminatedFOUND OIL IN NR 2 ENGINE AFT OF FAN AT 6 OCLOCK. CLEANED OIL RESIDUE FROM ENGINE. RAN NR 2 ENGINE AT IDLE. LEAK CHECKS OK. OK FOR CONTINUED SERVICE.SDR HALA2016042700142Power Supply · inoperativeRIGHT EMERGENCY CEILING LIGHT MID GALLEY INOPERATIVE. R & R POWER SUPPLY EMERGENCY LIGHT ASSY IAW WDM 33-51-12. OPS NORMAL, ACFT OK FOR SERVICE.SDR HALA2016042000142Power Supply · inoperativeRT EMERGENCY CEILING LIGHT MID GALLEY INOPERATIVE. R & R POWER SUPPLY EMERGENCY LIGHT ASSY IAW WDM 33-51-12. OPS NORMAL, ACFT OK FOR SERVICE.SDR HALA2016031000075Pump · malfunctionedRIGHT FEED FUEL PUMP INOPERATIVE CB POPPED IAW FIM28-22, FAULT 820 PERFORMED CHECKS OF WIRING & CONDUIT IAW AMM 28-22-15 AND WDM 28-22-11. NO FAULTS NOTED, COMPLIED WITH CDCCL REQUIREMENT. R & R FWD LT FUEL BOOST PUMP AMM CONT, ON LP 647382/2. REMOVED & INSSDR HALA2016022800060Pin · brokenDURING SERVICE CHECK FOUND EMERGENCY LIGHT BETWEEN ROW 17-27 INOPERATIVE. FOUND BROKEN PIN. REPLACED THE LIGHT IAW 767 AMM 33-51-10. ALSO FOUND BATTERY PACK INOPERATIVE. REPLACED BATTERY PACK IAW AMM 31-51-07. OPS CHECK GOOD, OK FOR SERVICE.SDR HALA2016021800051Autopilot Sys · malfunctionedDURING CLIMB WITH LEFT AUTOPILOT IN COMMAND, AUTOPILOT EICAS MESSAGE ILLUMINATED. RACKED LT SAM. GROUND OPS CHECK OK, IAW FIM 22-04, TASK 811. ACCOMPLISHED LAMP MCDP TEST 40. TEST PASS WITH NO FAULTS.SDR HALA2016021500043Starter · malfunctionedETOPS SIGNIFICANT SYS-APU DID NOT START ON FINAL, APU FAULT, EICAS. ACCOMPLISHED 2ND ATTEMPT AFTER QRH PROCEDURE. APU FAULT, EICAS AGAIN. R & R APU STARTER WITH SERVICEABLE STARTER IAW AMM 49-41-01. OPS CK OK.SDR HALA2016021000035Radar · out of toleranceBOTH LT AND RT RADAR'S NEED TO BE CALIBRABATED. BOTH SYS WERE NOT SHOWING WEATHER. BUT BOTH SYSTEMS TESTED OK. WXR BITE REF FIM 34-43, TREE 805, NO FAULTS NOTED. OPS CHECKED ON GROUND, REF AMM 34-43-00 GOOD. UNABLE TO DUPLICATE ON GROUND.SDR HALA2016020500028Starter · leakingDURING SERVICE CHECK FOUND APU STARTER LEAKING OIL. R & R THE APU STARTER IAW AMM 49-44-00, NO LEAKS NOTED. PERFORMED 2 APU STARTS SUCCESSFULLY OK FOR SERVICE.SDR HALA2016010600003Shutoff Valve · not reportedATB C HYD QTY EICAS HYD QTY .45. R & R FLAP SLAT SHUTOFF VALVE IAW AMM 27-51-48. OPS AND LEAK CHECK GOOD IAW AMM 27-51-48-712-074. OK FOR SERVICE.SDR HALA2015111200233Bracket · detachedATB BRACKET FELL FROM ABOVE DOOR 2L BEHIND PLEXIGLASS. INSTALLED BRACKET AT 2L DOOR FWD SIDE. SECURITY CHECK OK. DOOR OPS CHECK GOOD. OK FOR SERVICE.SDR HALA2015111200234Symbol Generator · malfunctionedATB 2, LEFT SYMBOL GENERATOR AND CENTER SYMBOL GENERATOR WENT COMPLETELY BLANK BEHIND PITCH LADDER. NO COLOR DIFFERENCE BETWEEN SKY AND GROUND INTERMITTENTLY. REPLACED CAPTAIN EADI IAW AMM 34-22-03. OPS CHECKED OK. PERFORMED MCDP TEST 30 TEST PASSED. LMP SSDR HALA2015111202303Bracket · detachedBRACKET FELL FROM ABOVE L2 DOOR BEHIND PLEXIGLASS. INSTALLED BRACKET. SECURITY CHECKED OK. DOOR OPS CHECKED GOOD. OK FOR SERVICE.SDR HALA2015101800212Battery Pack · inoperativeEMERGENCY LIGHTS AT DOORS R1 AND R2 INOPERATIVE. R & R EMERGENCY LIGHT BATTERY AT ROW 2R IAW AMM 33-51-07. OPS CHECK OF R1 AND R2 EMERGENCY LIGHTS IS GOOD.SDR HALA2015100900208Idg · making metalA RIGHT GENERATOR DRIVE EICAS MESSAGE AND DRIVE LIGHT ILLUMINATED, GENERATOR DRIVE DISCONNECT SWITCH ILLUMINATED. PERFORMED QRH PROCEDURE. DISCONNECTED DRIVE. FOUND RIGHT IDG DPI EXTENDED AND METAL PARTICLES ON SCAVENGE FILTER. AMM 24-11-01-246-211, NEED TSDR HALA2015092600200Probe · faultedRECEIVED AN EICAS MESSAGE FOR THE LT ENGINE ELECTRONIC CONTROL C1. IAW TROUBLESHOOTING, FOUND N1 SPEED PROBE FAULTING. R & R NR 1 ENGINE, N1 SPEED PROBE IAW AMM 73-21-06. OPS CHECK, LEAK CHECK GOOD. OK FOR SERVICE.SDR HALA2015092500199Warning Message · false activationSTATUS PG LT ENGINE ELECTRONIC ENGINE CONTROL C1. C/W FIM BITE TEST 71-01, TASK 808, NO FAULTS NOTED, FIM 73-21 FAULT TREE 828, NO FAULTS NOTED & C/W MCDP TEST 30, NO FAULTS NOTED. OK TO CONTINUE.SDR HALA2015091500193Charger · failedMAIN BATTERY CHARGER DISPLAYED ON STATUS PAGE. R & R MAIN BATTERY CHARGER IAW AMM 24-31-02. OPS CHECK GOOD. OK FOR SERVICE.SDR HALA2015090100181Flange · crackedCRACK ON NR 1 ENG STARTER FLANGE. REPLACED NR 1 ENGINE STARTER DRIVE GEARBOX HOUSING IAW ENGINE MANUAL 72-61-00. REPLACED STARTER DRIVE SEAL IAW ENGINE MANUAL 72-61-00. LEAK CHECK GOOD.SDR HALA2015083000179Control Valve · malfunctionedDURING DECENT, PACKS INCREASE TEMP TO APPROXIMATELY 85 DEG- A PACK RESET RESTORES AUTO TEMP CONTROL. R & R LT PACK TEMP CONTROL VALVE IAW AMM 21-51-12-404-013. OPS AND LEAK CHECK, OK.SDR HALA2015082600173Irs · out of alignmentCENTER IRS FAULT ON LANDING. ALIGNED CENTER IRS IAW 34-21-00-875-003. OPS CHECKED GOOD, NO FAULTS NOTED OK FOR SERVICE.SDR HALA2015082500172Warning Message · false activationRUDDER RATIO MESSAGE ILLUMINATED ON EICAS AFTER ENGINE START. FOUND RT RRCM WAS IN TEST MODE. IAW FIM 27-21 FAULT TREE 804 PLACED IN NORMAL POSITION. MESSAGE CLEARED. OK FOR SERVICE.SDR HALA201507160136Packing · leakingAIR TURNBACK DUE TO HYDRAULIC SYSTEM LEAK. REPLACED PRESSURE SWITCH AND PACKING ON THE FILTER MODULE IAW AMM 29-11-17. NO LEAKS NOTED,SDR HALA201507120135Start Valve · inoperativeNR 1 ENGINE START VALVE INOPERATIVE, START VALVE REPLACED IAW AMM 80-11-02-004/404 020. OPS CHECKED GOOD.SDR HALA2015070500127Unknown · unknownF/O ADI & HSI SG FAIL; F/O PRESSED EFI SWITCH TO CAPT SIDE SG DEPRESSED EFI SWITCH AND RESTORED SG OPS NORMAL-DESCENT PHASE OF FLIGHT. ACCOMP FIM34-22-808 NO FAULTS NOTED DURING BITE CHK; ACCOMPLISHED MCDP TEST 40 AND SYS PASSED; ACFT TO REMAIN IN LAND 3 SSDR HALA2015051500081Skin · corrodedATS HAS DISCOVERED CORROSION ON THE UPPER SURFACE OF THE LT WING UPPER SKIN AT WING FS 616.2. DURING MINOR CORROSION REMOVAL IAW SRM IT WAS NECESSARY TO REMOVE FASTENER IN THE BLENDOUT AREA. ATS HAS ATTMEPTED TO REMOVE FASTENER IN THE BLENDOUT AREA, HOWEVER SDR HALA2015042500077Floor Support · crackedCABIN FLOOR SUPPORT CRACKED AT BS 566-588 LBL 39. R & R IAW SRM 51-40-02-060.SDR HALA2015042500075Floor Support · crackedCABIN FLOOR SUPPORT CRACKED AT BS 566-588 RBL 39. REMOVED, FABRICATED A NEW FLOOR SUPPORT IAW DWG 1490-2843 AND SRM 53-30-51-01-1 DETAIL 1. TRIMED AND DRILLED AND INSTALLED IAW SRM 51-30-01-0G-0 AND SRM 51-40-05-0G-0.SDR HALA2015042200090Scuff Plate · crackedR-2 DOOR AFT SCUFF PLATE CRACKED. R & R CRACKED SCUFF PLATE AT R-2 DOOR IAW AMM TASK 53-13-01-024-001 & AMM TASK 53-13-01-424-005.SDR HALA2015042200078Angle · brokenFWD ENTRY DOOR INBD THRESHOLD HAT CLIP IS BROKEN AT STA 324, LBL 88, WL 200. REMOVED HAT CLIP AT STA 324, LBL 88, WL 200, IAW SRM 51-40-02-0G-0. LOCATED, DRILLED AND INSTALLED NEW HAT CLIP IAW SRM 51-24-22-370-802 AND AMM 51-00-59-112-002.SDR HALA2015042200076Angle · brokenFWD ENTRY DOOR INBD THRESHOLD HAT CLIP IS BROKEN BS 312, LBL 88, WL200. REMOVED BROKEN HAT CLIP AT STA 312, LBL 88, WL 200 IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED HAT CLIP AND INSTALLED NEW HAT CLIP IAW SRM 51-24-22-370-802 AND AMM 51-00-59-112-002.SDR HALA2015042200074Angle · crackedFWD ENTRY DOOR INBD THRESHOLD HAT CLIP IS CRACKED AT FS 329, LBL 88, WL 200. REMOVED AND REPLACED IAW SRM 51-40-OG-0 AND AMM 51-21-10-3070020.SDR HALA2015042200073Angle · bentFWD ENTRY DOOR INBD THRESHOLD HAT CLIP IS BENT AT BS 305, LBL 88, WL 200. R & R IAW SRM 51-40-02-0G-0.SDR HALA2015040600001Radio Altimeter · malfunctionedDURING FINAL APPW/"APP ARMED" NO LAND 3 STATUS APPEARED. REPLACED CENTER RADIO ALTIMETER. OPS CHECK OK IAW MM 34-33-01. PERFORMED MCDP TEST 30. TEST PASSED. ACFT REMAINS IN LAND 3 LMP STATUS.SDR HALA2015031000033Regulator Valve · unknownETOPS SIGNIFICANT EVENT, LT ENGINE PRV EICAS ILLUMINATED ON CLIMBOUT. R & R LT ENGINE PRESSURE REGULATING VALVE IAW AMM 36-11-18-004-001-002, AND AMM 36-11-18-404-017-002. LEAK AND OPS CK OK. RAN ENGINE IAW AMM 71-00-00. BLEED OPS NORMAL. LT ENGINE PRV DSDR HALA2014100800166Control Unit · malfunctionedAIR TURNBACK DUE TO LT MAIN TANK FUEL INDICATOR AND TOTALIZER BLANK. CHECKED FUEL QTY UNIT, FOUND NO PRESENT FAULT. IN FAULT HISTORY "00", FOUND LM TU1,2,3,4,5 CONTAMINATED, LM TU10,11,12,13,14 OPEN LOZ OR HIZ WIRE, LM CONPENSATOR CONTAMINATED, LM DENS CONTASDR HALA2014100800Control Unit · contaminatedAIR TURNBACK DUE TO LT MAIN TANK FUEL INDICATOR AND TOTALIZER GOING BLANK. CHECKED FUEL QTY UNIT, FOUND NO PRESENT FAULT. IN FAULT HISTORY "00", FOUND LM TU1 2, 3, 4, 5 CONTAMINATED, LM TU 10, 11, 12, 13, 14. OPEN LOZ OR HIZ WIRE, LM CONPENSATOR CONTAMINATESDR HALA2014041100056Skin · damagedLEFT WING LOWER SURFACE, PAINT ON LOWER SURFACE FLAKING OFF AT MULTIPLE LOCATIONS. NOTE PAINT STRIP MOST LOCATIONS SHOWED SIGNS OF CORROSION. ALL BUT 3 AREAS CLEANED OF ALL CORROSION WITHIN APPROVED SRM LIMITS 57-20-01, FIG 103, TABLE 11.SDR HALA2014011000003Warning Message · illuminatedDURING CRUISE, STATUS PAGE MESSAGE DISPLAYED FOR RT ENGINE EEC C1. FOLLOWED FIM 73-21/828. FOUND MESSAGE CH-B, CAT 1 FAULT ON RT PIMU FOLLOWED BY PIMU MESSAGE TABLE IAW FIM TASK 71-01-00/201 AND PERFORMED BITE/GROUND TEST OF PIMU THEN RESET, MESSAGE WENT OUTSDR HALA2013121000178Drive Unit · failedRADAR SYS FAILED DURING CLIMBOUT. WX FAIL ON NAV DISPLAY SX SYS ON STATUS PAGE WITH EITHER RADAR SYSTEM SELECTED. RETURNED TO DEPARTURE. REPLACED WEATHER RADAR DRIVE UNIT AND ANTENNA FLAT PLATE IAW AMM 34-43-05. PERFORMED OPS TEST PER AMM TASK 34-43-05-714-SDR HALA2013112300171Ratio Changer · malfunctionedCLIMBING OUT, RECEIVED EICAS RUDDER RATIO MESSAGE & LIGHT. FOLLOWED QRH AND LT HYDRAULIC WAS NORMAL. FIM27-21 BITE OF BOX NO FAULTS, R & R RT RUDDER RATIO CHANGER, IAW AMM 27-09-00. OPS TEST OF RUDDER AND RUDDER TRIM CONTROL SYS IAW AMM 27-21-00. OPS CHECSDR HALA2013110500166Unknown · malfunctionedAIR TURN BACK, RUDDER RATIO, AIRERON LOCKOUT & ALL THREE AUTOPILOTS WON'T ENGAGE. ACCOMPLISHED FIM TASK 73-21/892, 27-21-804 & 27-48-809 PROCEDURES. UNABLE TO DUPLICATE ON GROUND. PIMU BITE CHECKED, NO FAULTS FOUND. STAB TRIM AND RUDDER RATIO TRIM OPS CHECSDR HALA2013090300103Structure · crackedONE INCH CIRCUMFERENTIAL CRACK INTERSECTING WITH AN AXIAL CRACK LT ENGINE COMBUSTION CHAMBER INNER LINER COLD SECTION, ALONG NR 6 LOUVER KNUCKLE AREA. VIEWED FROM 277 DEGREES AP-8. R & R ENGINE.SDR HALA2013071500088Processor · failedABOUT ONE HOUR TEN MINUTES BEFORE LANDING, LOST LT FUEL QTY AND TOTAL FUEL QTY INDICATION, GOT FUEL QTY IN ON EICAS DISPLAY. ALSO LOST TOTALIZER ON FMC. ACCOMPLISHED LM FUEL QTY INSULATION RESISTANCE TEST IAW AMM 28-41-00. ALL RESISTANCE WITHIN LIMITS. R &SDR HALA2013070100085Ecu · faultedAPU FAULT. REPLACED APU ECU IAW AMM 49-61-05, PERFORMED ECU SELF AND BITE TEST, TEST PASSED, APU START ON GROUND NORMAL ON FIRST ATTEMPT, NO FAULTS NOTED, OIL QTY NORMAL.SDR HALA2013061600079Window · failedCAPTAIN`S FWD WINDOW SHATTERED. R & R CAPTAIN'S NR 1 WINDOW IAW AMM 56-11-01 UP TO STEP 16B. COMPLETED INST OF WINDOW IAW AMM 56-11-01 AND COND CHECK GOOD. OK FOR SERVICE.SDR HALA2013051800061Indication Sys · inaccurateLEFT FUEL QTY GAUGE SHOWED 10,000 LB DIFFERENCE AND WHEN BLANK DURING TAXI. FOLLOWED FIM PROCEDURE 28-41, FAULT TREE 847. CLEANED & SECURED DENSITOMETERS, LO-Z, HI-Z E/PLUG AND FQIS BITE TEST PASSED. TAXING CHECK GOOD AND FUEL INDICATION SYS CHECKED OK IAW SDR HALA2013030200028Fmu · failedLT ENGINE NO FUEL FLOW. TWO STARTS ATTEMPTED. R & R FUEL FLOW TRANSMITTER IAW AMM 73-31-01. LEAK CHECKED OK. CONDITION SAME. R & R FMU FOR NR 1 ENGINE IAW 73-21-01. LEAK CHECKED GOOD. OPS CHECKED GOOD. GROUND IDLE RUN CHK OK.
Back to N580HA, cancelled Feb 21, 2019