SDR HNAA2019121100382Radar · failedWX RADAR FAILED IN FLIGHT.AMBER WX INSCRIPTIONS AND GIVING ERRONEOUS READINGS.WX RADAR TEST FAILED....FIX:PERFORMED OPERATIONAL CHECK OF WX RTA REF. AMM 34-42-00-700-801-A OPS CHECK GOOD. OK FOR SERVICEDec 10, 2019 · N601DW · Emb EMB145LR · Weather Radar SystemSDR HNAA20190607165Profile · gougedUPPER "L" PROFILE FRAME ON FWD PRESSURE BULKHEAD IS GOUGED NEAR CENTER POST... FIX: REMOVED PROFILE,REPAIRED PER ETD2019-145-072931, REINSTALLED PROFILE FRAME ON FWD PRESSURE BULKHEAD IAW ENB SRM 51-40-02Jun 7, 2019 · N601DW · Emb EMB145LR · Fuselage Main, BulkheadSDR HNAA2019060700164Bulkhead Web · crackedFWD PRESSURE BULKHEAD CRACKED.... FIX:INSTALLED DOUBLER, FILLER AND SHIMS FOR REPAIR OF FWD PRESSURE BULKHEAD AT UPPER CENTER AREA IAW ETD2019-145-069777 REV A.Jun 7, 2019 · N601DW · Emb EMB145LR · Fuselage Main, BulkheadSDR HNAA2019060700163Profile · crackedCENTER "T" PROFILE CRACKED ON THE FWD PRESSURE BULKHEAD,FWD FACE, UPPER AREA... FIX: INSTALLED NEW FWD PRESSURE BULKHEAD "T"PROFILE IAW EMB-145 SRM 51-40-02.Jun 7, 2019 · N601DW · Emb EMB145LR · Fuselage Main, BulkheadSDR HNAA2019061100171Fitting · brokenWINDSHIELD CENTER POST LOWER FITTING BROKEN. R & R WINDSHIELD CENTER POST LOWER FITTING IAW EO1-53-19-0192 AND SB 145-53-007.Jun 2, 2019 · N601DW · Emb EMB145LR · Fuselage Main, StructureSDR HNAA2018090400210Warning System · false activationBLEED 1 VALVE CLOSED ADVISORY DISPLAYED AFTER T/O WITH VERY LOW BLEED TEPERATURE. RAN ENGINE 1 ON GROUND AT DIFFERENT THRUST SETTINGS AND PERFORMED ENG BLEED VALVE OPERATIONAL CHECK IAW AMM 36-11-05. NO ISSUES NOTED. OKAY FOR SERVICE.Aug 31, 2018 · N601DW · Emb EMB145LR · Pneumatic Indicating SystemSDR HNAA2018052100005Inverter · inoperativeFLOOR EMERGENCY LIGHTS INOPERATIVE AT THE EMERGENCY EXIT. R & R THE INVERTER IAW AMM 33-50-11.May 20, 2018 · N601DW · Emb EMB145LR · Emergency LightingSDR HNAA2018052500106Fan · failedBOTH BLEEDS OVERTEMP WARNINGS AT 16K, AFTER ICE PROTECTION HAD BEEN ON FOR 5 MINUTES. APU WAS NOT ON. REMOVED AND REPLACED THE NR 1 & 2 THERMOSTAT FAN A/C AND THERMOSTAT MOUNT TUB ASSY IAW SB 145-36-0028.May 6, 2018 · N601DW · Emb EMB145LR · Pneumatic Distribution SystemSDR HNAA2018043000092Tube · failedBLEED 1 LEAK EICAS MESSAGE DISPLAYED DURING CLIMBOUT. REMOVED AND REPLACED THE TUBES IAW AMM 36-13-00. PERFORMED A BLEED AIR LEAK CHECK IAW AMM 36-00-00. PERFOMED AN EBV FUNCTIONAL CHECK IAW AMM 36-11-05. LEAK AND OPS CHECKED GOOD. OK FOR SERVICE.Apr 27, 2018 · N601DW · Emb EMB145LR · Compressor Bleed ControlSDR HNAA2018031600060Indicator · malfunctionedDURING CRUISE ALTITUDE, THE STBY ALTIMETER WAS INDICATING 1800 FEET LOWER THAN ADC AND THE STBY AIRSPEED INDICATOR WAS 25 KNOTS SLOWER THAN ADC. R & R THE STANDBY ALTIMETER IAW AMM 34-11-01. OPS CHECKED GOOD.Mar 15, 2018 · N601DW · Emb EMB145LR · Altimeter, Barometric/EncoderSDR HNAA2018021400031Landing Gear · unknownAT WHEELS UP, TWO LOUD THUMPING NOISES WERE HEARD COMING FROM NOSE AREA, ALONG WITH A HISSING SOUND. NO ABNORMAL INDICATIONS NOTED. EVALUATION FLIGHT SATISFACTORY.Feb 12, 2018 · N601DW · Emb EMB145LR · Nose/Tail Landing GearSDR HNAA2018020700026Bulb · inoperativeOVERHEAD EMERGENCY LIGHT AT THE PAX DOOR WAS FOUND INOPERATIVE. R & R THE BULB.Feb 6, 2018 · N601DW · Emb EMB145LR · Emergency LightingSDR HNAA2017092500326Brake · leakingLEFT BRAKES APPEAR TO BE SMOKING ON LANDING. NR 2 HYD QTY APPEARED TO BE DROPPING. FOUND THE LEFT MAIN BRAKE INBD LEAKING WHEN HYD PRESSURE IS APPLIED. R & R THE MAIN BRAKE ASSY IAW AMM 32-49-03. OPS CHECKED GOOD, OK FOR SERVICE.Sep 22, 2017 · N601DW · Emb EMB145LR · Landing Gear Brake SystemSDR HNAA2017070500225Warning Light · false activationDURING NR 2 ENGINE START, NR 2 PITOT INOPERATIVE CAUTION MESSAGE CAME INTO VIEW. OPS CHECKED GOOD.Jul 4, 2017 · N601DW · Emb EMB145LR · Central WarningSDR HNAA2017070500227Connector · dirtyLOW PRESSURE COMPRESSION INDICATION AT HIGHEST POINT IN THE YELLOW RANGE. CLEANED THE FADEC 1A & 1B CONNECTORS IAW MM 70-00-00, RAN ACFT, NO DEFECTS NOTED.Jul 1, 2017 · N601DW · Emb EMB145LR · Engine Indicating SystemSDR HNAA2017051200166Display · malfunctionedFIRST OFFICER`S ALTITUDE INDICATION MISSING ON PFD. TURNED OFF AVIONCIS AND PDU FOR 15 MIN. OPS CHECKED GOOD.May 11, 2017 · N601DW · Emb EMB145LR · Navigation SystemSDR SIMA20170125006Rib · crackedLT WING RIB 5 CRACKED. REPLACED LT RIB 5 IAW ERS EO EM-57MR-764.Jan 25, 2017 · N601DW · Emb EMB145LR · Wing, Rib/BulkheadSDR SIMA20170123007Skin · damagedFRAME 60 -61 PROTRUSION AT STRINGER 17L. ACCOMPLISHED REPAIR TO FRAME 60 - 61 AT STRINGER 17L IAW ERS-EM-53MR-2555.Jan 23, 2017 · N601DW · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20170122004Drag Angle · crackedVERTICAL STAB LT DRAG ANGLE CRACKED AFT OF FR 75 PREVIOUS REPAIR. PERFORMED PERMANENT REPAIR OF VERTICAL STAB LT DRAG ANGLE AFT OF FR 75 IAW SRM 51-40-02.Jan 22, 2017 · N601DW · Emb EMB145LR · Fuselage, Stabilizer Attach FittingsSDR SIMA20170121003Frame · gougedFRAME 65 PREVIOUS REPAIR GOUGED BTW STR 12R - 13R. PERFORMED PERMANENT REPAIR ON FR 65 BTW STR 12R-13R IAW ERS-EM-53MR-2545.Jan 21, 2017 · N601DW · Emb EMB145LR · Fuselage Main, FrameSDR SIMA20170121002Floorbeam · corrodedLT FLOORBEAM WEB CORRODED AT CENTER AISLE CROSSMEMBER AT FR 29. PERFORMED PERMANENT REPAIR OF CENTER AISLE CROSSMEMBER AT FR 29 IAW ERS-EM-53MR-2552Jan 21, 2017 · N601DW · Emb EMB145LR · Fuselage Main, Floor BeamSDR SIMA20170120004Skin · canningFUSELAGE SKIN HAS PROTRUSION AND OIL CANNING BETWEEN FRAMES 7 AND 8 STR 13L - 15L. PERFORMED PERMANENT REPAIR OF FR 7-8 STR 13L-15L IAW ERS-EM-53MR-2522.Jan 20, 2017 · N601DW · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20170116003Floorbeam · corrodedLT FLOORBEAM WEB CORRODED AT CENTER AISLE CROSSMEMBER AT FR 38. PERFORMED PERMANENT REPAIR OF CENTER AISLE CROSSMEMBER AT FR 38 IAW SRM 53-00-10 ITEM 3 FIG 202 SHEET 1.Jan 16, 2017 · N601DW · Emb EMB145LR · Fuselage Main, Floor BeamSDR SIMA20161218005Inverter · failedEMERGENCY LIGHT ABOVE SERVICE DOOR INOPERATIVE. REMOVED AND REPLACED THE INVERTER IAW AMM 33-50-11. OPS CHECKED GOOD IAW AMM 33-50-00.Dec 18, 2016 · N601DW · Emb EMB145LR · Emergency LightingSDR SIMA20161129002Flashlight · inoperativeCABIN FLASHLIGHT HAS NO RED CHARGE LIGHT. REMOVED AND REPLACED CABIN FLASH LIGHT IAW STANDARD MTX PRACTICES.Nov 29, 2016 · N601DW · Emb EMB145LR · Emergency EquipmentSDR SIMA20160807001Warning Message · false activationON PUTTING GEAR DOWN FOR FINAL APPROACH, EICAS MESSAGE BRAKE DEGRADE. WENT AROUND DID AOM1 CHECKLIST. DECLARED EMERGENCY AND LANDED WITHOUT INCINDENT. PERFORMED MAIN BRAKE FUNCTIONAL CHECK IAW AMM 32-41-00. FNC FAILED AT STEP J.2.H. CONTINUED FROM AMM 32-4Aug 7, 2016 · N601DW · Emb EMB145LR · Landing Gear Brake SystemSDR SIMA20160708004Wire · damagedEMERGENCY LIGHT IN THE SERVICE DOOR INOPERATIVE. REPAIRED WIRE FOR SERVICE DOOR AT SPLICE SP7376 IAW SWPM 20-21-00, EMERGENCY LIGHTS OPS CHECK GOOD IAW AMM 33-50-00.Jul 8, 2016 · N601DW · Emb EMB145LR · Light System WiringSDR SIMA20160425001Holder · defectiveFIRST OFFICERS FLASHLIGHT NOT SECURE TO FLASHLIGHT BASE. R & R FIRST OFFICERS FLASHLIGHT BASE IAW AMM 33-50-16.Apr 25, 2016 · N601DW · Emb EMB145LR · Emergency EquipmentSDR SIMA20160311004Hydraulic Line · crackedEMERGENCY HYD BRAKE LINE, UNDER COCKPIT FLOOR CRACKED & LEAKING. REPAIRED EMER HYD BRAKE LINE IAW AMM 20-10-03. LEAK & OPERATIONS CHECKED GOOD.Mar 11, 2016 · N601DW · Emb EMB145LR · Hydraulic System, MainSDR SIMA20160226001Holder · brokenFORWARD FLIGHT ATTENDANT FLASHLIGHT HOLDER IS BROKEN & DOES NOT HOLD FLASHLIGHT PROPERLY. R & R FLASHLIGHT ASSEMBLY IAW AMM 33-50-16, NO DEFECT NOTED.Feb 26, 2016 · N601DW · Emb EMB145LR · Emergency EquipmentSDR SIMA20160208001Cradle · inoperativeAFT FLASHLIGHT INOPERATIVE. CHANGE FLASHLIGHT HOLDER.Feb 8, 2016 · N601DW · Emb EMB145LR · Emergency EquipmentSDR SIMA20151226002Splice · defectiveSERVICE DOOR EMER LIGHT INOPERATIVE. R & R REMOVABLE SPLICE AT SERVICE DOOR EMER EXTERNAL LIGHT IAW SWPM 20-21-00. OPERATIONS CHECKED GOOD.Dec 26, 2015 · N601DW · Emb EMB145LR · Light System WiringSDR SIMA20150925001Pressure Switch · malfunctionedYAW DAMP FAIL. R & R RUDDER SYS 2 PRESS SWITCH IAW AMM 27-23-04. PERFORMED LEAK CHECK, LEAK CHECKED GOOD. PERFORMED OPERATIONS CHECK RUDDER SYS 2 IAW AMM 27-263-00. OPERATIONS CHECKED GOOD.Sep 25, 2015 · N601DW · Emb EMB145LR · Rudder Control SystemSDR SIMA20150917001Flashlight · inoperativeCAPTAINS FLASHLIGHT NOT CHARGING. R & R CAPTAINS FLASHLIGHT IAW AMM 33-50-16. 0PERATIONS CHECKED GOOD.Sep 17, 2015 · N601DW · Emb EMB145LR · Emergency EquipmentSDR SIMA20150522002Battery · dischargedMULTIPLE CABIN EMER LIGHTS INOPERATIVE. SUSPECT PROBLEM WITH EPSU NR 3. R & R NR 3 EMER LIGHT BATTERY & CHARGER IAW WC 33-700-19. OPERATIONS CHECKED GOOD, NO DEFECTS NOTED AT THIS TIME.May 22, 2015 · N601DW · Emb EMB145LR · Emergency LightingSDR SIMA20150521003Inverter · inoperativeCOCKPIT STEP EMER LIGHT INOPERATIVE. R & R EMER LIGHT DC & AC INVERTER IAW AMM 33-50-11. OPERATIONS CHECKED GOOD.May 21, 2015 · N601DW · Emb EMB145LR · Emergency LightingSDR SIMA20150508004Light · inoperativeEMERGENCY LIGHT STRIP ON FLOOR BY 6A INOPERATIVE. R & R EMER LIGHT STRIP BY 6A IAW AMM 33-50-12. OPERATIONS CHECKED GOOD, NO DEFECTS NOTED.May 8, 2015 · N601DW · Emb EMB145LR · Emergency LightingSDR SIMA20150504003Light · inoperativeFIRST OFFICERS FLASHLIGHT INOPERATIVE. TROUBLE SHOT FIRST OFFICERS FLASHLIGHT, FOUND LAMP BURNED OUT. R & R LAMP IAW CMM 25-60-11.May 4, 2015 · N601DW · Emb EMB145LR · Emergency EquipmentSDR SIMA20150429001Battery · discharged1/2 OF EMER LIGHTING NOT WORKING. R & R NR 4 EMER BATTERY ASSEMBLY IAW AMM 33-50-04. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.Apr 29, 2015 · N601DW · Emb EMB145LR · Emergency LightingSDR SIMA20150325001Inverter · inoperativeESCAPE PATH EMER LIGHTING ON LT SIDE ROWS 7 - 15 OTS. R & R NR 4 AC TO DC INVERTER IAW AMM 33-50-11. OPERATIONS CHECKED GOOD.Mar 25, 2015 · N601DW · Emb EMB145LR · Emergency LightingSDR SIMA20150308003Light · inoperativeCABIN NR 5 FLOOR PROXIMITY STRIP LIGHT INOPERATIVE. R & R CABIN NR 5 FLOOR PROXIMITY STRIP LIGHT IAW AMM 33-50-12. OPERATIONS CHECKED GOOD.Mar 8, 2015 · N601DW · Emb EMB145LR · Emergency LightingSDR SIMA20150303005Sleeve · blownWHILE RUNNING PROCEDURES FOR ITEM NR 1, RECEIVED PACK 2 OVLD, FOLLOWED BY BURNING SMELL. FOUND BLOWN SLEEVE FWD OF D C V CAUSING BURNING SMELL. R & R SLEEVE AMM 21-60-01. LEAK CHECK & OPERATIONS CHECKED GOOD AT THIS TIME.Mar 3, 2015 · N601DW · Emb EMB145LR · Cabin Cooling SystemSDR SIMA20150303004Clamp · failedDURING CLIMB CREW RECEIVED PACK 1 OVLD MSG FOLLOWED BY PACK 1 OVLD MSG. CREW COMPLIED WITH AOM VOL 1 PROCEDURES, DECLARED AN EMER & RETURNED WITHOUT INCIDENT. FOUND BROKEN CLAMP AT PACK 1 VALVE. R & R CLAMP IAW AMM 21-51-01. LEAK & OPS CHECKED GOOD.Mar 3, 2015 · N601DW · Emb EMB145LR · Cabin Cooling SystemSDR SIMA20150104005Skin · crackedFRAME 75 FASTENER SKIN AREA CRACKED BELOW STRINGER 2L. ACCOMPLISHED FRAME 75 BELOW STRINGER 2L SKIN REPAIR IAW ERS-EM-53MR-984.Jan 4, 2015 · N601DW · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20150104006Skin · crackedFRAME 75 SKIN AT FASTENER AREA CRACKED ABOVE STRINGER 2R. ACCOMPLISHED FRAME 75 ABOVE STRINGER 2R SKIN REPAIR IAW ERS-EM-53MR-984.Jan 4, 2015 · N601DW · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20150103002Spar · crackedCRACK ON LT WING SPAR III AT HOLE FOR MLG HARNESS AT APPROX THE 7 O'CLOCK POSITION BETWEEN RIBS 3 & 4. ACCOMPLISHED REPAIR ON LT WING SPAR III AT HOLE FOR MLG HARNESS IAW ERS-EM-57MR-349. FOUND DURING EO-EM-5700-662.Jan 3, 2015 · N601DW · Emb EMB145LR · Wing SparSDR SIMA20150103003Spar · crackedCRACK ON RT WING SPAR III AT HOLE FOR MLG HARNESS AT APPROX THE 4 O'CLOCK POSITION BETWEEN RIBS 3 & 4. ACCOMPLISHED REPAIR ON RT WING SPAR III AT HOLE FOR MLG HARNESS IAW ERS-EM-57MR-350. FOUND DURING EO-EM-5700-662.Jan 3, 2015 · N601DW · Emb EMB145LR · Wing SparSDR SIMA20150102011Support · crackedLEFT PYLON FWD LOWER YOKE FWD ENG MOUNT SUPPORT IS CRACKED. ACCOMPLISHED REPAIR TO LT PYLON FWD LOWER YOKE FWD ENG MOUNT SUPPORT IAW EO-EM-54MR-386 PART A.Jan 2, 2015 · N601DW · Emb EMB145LR · Engine Mount SectionSDR SIMA20150102012Door Frame · corrodedSERVICE DOOR FRAME CORRODED BELOW AFT LOWER ROLLER. PERFORMED SERVICE DOOR FRAME CORROSION REPAIR IAW ERS EM -53MR-971.Jan 2, 2015 · N601DW · Emb EMB145LR · Fuselage Main, StructureSDR SIMA20150102009Connector · missingWIRE FOR FLOOR PROXIMITY LIGHT STRIP NR 4 IS MISSING CONNECTOR WHERE IT PASSES THRU THE FLOORBOARD. INSTALLED CONNECTOR TO NR 4 PROXIMITY LIGHT STRIP IAW SWPM 20-21-0. FOUND DURING OPEN UP.Jan 2, 2015 · N601DW · Emb EMB145LR · Light System Wiring
Back to N601DW, cancelled Jan 7, 2021