N6040U, cancelled Apr 23, 1998
Service difficulty reports · 17
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N6040U' AND deregistration_id = 'N6040U-1998-04-23' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N6040U' AND deregistration_id = 'N6040U-1998-04-23' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HEEA0012199Indicator · defectiveHIGH RESISTANCE ACROSS RED AND BLUE WIRES.SDR HEEA0010499Indicator · reads lowDUAL T4 INDICATOR #1 INDICATES LOW OUT OF TOLERANCE.SDR HAIHEEA9527Transmitter · fluctuationOIL PRESSURE TRANSMITTER FAULTY. FLUCTUATING OIL PRESSURE AT IDLE.SDR HAIHEEA9526Transmitter · failedPRESSURE TRANSMITTER NOT TRANSMITTING. PRESSURE INDICATING -0-.SDR HAIHEEA9475Yoke · bearing failedBEARINGS SEPARATED. REPLACED WITH SERVICEABLE YOKE ASSEMBLY.SDR HEEA968557Battery · defectiveBATTERY WEAK. INSPECTED BY ACCESSORY SHOP AND FOUND BATTERY WOULD NOT PASS CAPACITY TEST. BATTERY PUT INTO SERVICE 7-12-95.SDR HEEA967584Wheel · crackedENGINE REMOVED DUE TO HIGH OIL CONSUMPTION. UPON INSPECTION OF TURBINE PARTS DUE TO LOW POWER ON TEST CELL NOTED THE FOLLOWING: ONSET OF SULPHIDATION ON 20 EACH 1ST STAGE WHEEL BLADES AND CRACKED IN RIM AREA. SCRAPPED 1ST STAGE WHEEL.SDR HEEA966786Encoder · errorENCODER 200 FEET OFF AND WILL NOT CALIBRATE.SDR HEEA966685Transceiver · defective2 YEAR INSPECTION DUE. REPLACED WEAK V101 CAVITY OSCILLATOR, WEAK V301 PHOTO DETECTOR AND DETERIORATED R477 RESISTOR. ADJUSTED AND BENCH CHECK GOOD.SDR HEEA966652Transmitter · failedFUEL GAUGE READS "0".SDR HEEA966612Transmitter · failedFUEL PRESSURE TRANSMITTER DROPS TO ZERO PRESSURE.SDR HEEA966545Armature · shortedINSTALLED ARMATURE IN STARTER GEN. WHEN PUT ON TEST, BRUSHES WERE ARCHING EXCESSIVELY. FOUND ARMATURE COMMENTATOR SHORTED OUT.SDR HEEA955646Transceiver · defectiveVERY LOUD STATIC NOISE ON ALL FREQUENCIES.SDR HEEA955379Balljoint · wornTEFLON WORN. REPLACED WITH SERVICEABLE BALL JOINT.SDR HEEA955349Transmitter · defectivePRESSURE DROPS TO ZERO IN FLIGHT. (INTERMITTENTLY) TIME SINCE REPAIR 262:50.SDR HEEA954881Transmitter · failedNO INDICATION ON GAUGE. TIME SINCE REPAIR 516:55.SDR HEEA954287Sensor Assy · broken plugAUTO RELIGHT COMES ON DURING FLIGHT. FOUND BROKEN CANNON PLUG.