N609FF, cancelled Oct 24, 2013
Service difficulty reports · 47
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N609FF' AND deregistration_id = 'N609FF-2013-10-24' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N609FF' AND deregistration_id = 'N609FF-2013-10-24' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR TWRA9806Slide · brokenDURING SCHEDULED SLIDE DEPLOYMENT AT 5L DOOR, SLIDE FAILED TO DEPLOY. ON INVESTIGATION FOUND LEFT SIDE RELEASE CABLE WOULD NOT PULL PIN OUT OF THE PACKBOARD DUE TO THREADER STRAP BROKEN OFF FROM CABLE. SLIDE WAS REPLACED. (M)SDR TWRA97196Hyd Pump · crackedAFTER TAKEOFF, NR 4 HYDRAULIC SYSTEM DECREASED TO 4 GALLONS. ENGINE PUMP DPERSSURIZED QUANTITY CONTINUED TO DECREASE. AIRCRAFT TURNBACK JFK. REMOVED AND REPLACED ENGINE DRIVEN PUMP. PRESSURE FILTER AND CASE DRAIN FILTER PER MM 29-11-05 MM 29-11-18 AND 29-11SDR TWRA97197Light · looseDURING B-SERVICE, FOUND UPPER DECK EXIT LIGHT ON TOP OF SPIRAL STAIRCASE PEDESTAL LOOSE AND TAPED UP. REPLACED EXIT SIGN LIGHT AS PER MM 33-51-00. OPERATIONAL CHECK OK. (M)SDR TWRA97188Window · crackedDURING B-SERVICE, FOUND PASSENGER CABIN WINDOW NR 29L CRACKED AT LEADING EDGE OF WINDOW. REMOVED AND REPLACED CABIN WINDOW NR 29L AS PER MM 56-21-01. (M)SDR TWRA97187Slide Strap · brokenWHILE ATTEMPTING A SLIDE/RAFT DEMONSTRATION FOR A GROUP OF FLIGHT ATTENDANTS AT JFK, THE SLIDE FAILED TO DEPLOY DUE TO GRID LANYARD STRAP SNAPPED IN HALF (SLIDE NOT MOUNTED AT THE DOOR ATTACHED TO FLOOR BRACKET). REMOVED SLIDE AND SHIPPED TO VENDOR FOR EVALUASDR TWRA97157Light · inoperativeDURING DAILY SERVICE, FOUND R4 DOOR UPPER BUSTLE LIGHT INOPERATIVE. REMOVED AND REPLACED BUSTLE LIGHT. OPS CHECKED OK PER MM 33-51-00. (X)SDR TWRA97152Hydraulic Line · failedDURING CLIMB-OUT, EN ROUTE FROM LAX, LOST NR 1 HYDRAULIC SYSTEM. MAINTENANCE AT JFK FOUND HYDRAULIC PRESSURE LINE SHEARED INSIDE NR 1 PYLON. REMOVED AND REPLACED HYDRAULIC LINE, PRESSURE CASE DRAIN AND RETURN FILTERS. ALSO, REPLACED ADP AND EDP PER MM 2-11-1SDR TWRA97150Fuse · blownDURING DAILY SERVICE, FOUND R3 MED EXIT SIGN INOP. INSTALLED FUSE ON POWER SUPPLY, OPS CHECK OK PER MM 33-51-00. (M)SDR TWRA97119Light · inoperativeDURING DAILY CHECK, FOUND RIGHT SIDE OVERWING EMERGENCY LIGHT 2ND FROM FRONT ONE, BULB INOP. REPLACED ASSEMBLY, OPS CHECK GOOD PER MM 33-51-00. (M)SDR TWRA9120Wire · brokenDURING DAILY CHECK, FOUND 3AC BOTH SEAT EGRESS LIGHTS INOP. REPAIRED BROKEN WIRE BY SEAT 3AC. OPS CHECKED OK PER MM 33-51-00. (M)SDR TWRA97121Wire · brokenDURING DAILY CHECK, FOUND R1 DOOR BUSTLE EMERGENCY LIGHT INOP. REPLACED LIGHT ASSEMBLY AND REPAIRED BROKEN WIRE. OPS CHECKED GOOD PER MM 33-51-00. (M)SDR TWRA9798Line · failedNR 3 HYDRAULIC SYSTEM QUANTITY DECREASED FROM 7.8 AT BEGINNING OF FLIGHT TO 5.4 GALLONS AT END OF FLIGHT. REPLACED FLEX LINE WITH SOLID RIGID LINE PER MM 29-11-096. OPS CHECKED NORMAL (7-10-97). (X)SDR TWRA9794Control Unit · malfunctionDURING TAKEOFF, RUDDER RATIO LIGHT CAME ON. RE-SEATED CONNECTOR ON RUDDER RATIO COMPARATOR. OPS CHKS OK PER MM 27-21-12, PAGES 501-504. ITEM REPEATED 5-12-97. REPLACED UPPER RUDDER CONTROL UNIT. SYSTEM OPS CK OK PER MM 27-21-12. RUN-UP CK IAW MM 27-00-00SDR TWRA97108Wire · brokenJFK - DURING DAILY SERVICE, FOUND UPPER DOOR BUSTLE LIGHT INOPERATIVE AT 1L MED. ALSO, ABOVE AISLE MOUNTED EXIT SIGN INOPERABLE. FOUND BROKEN WIRE AT BUSTLE AND BACK OF SIGN. REPAIRED BROKEN WIRE. OPS OK PER MM 33-51-00. (X)SDR TWRA9779Wire · brokenDOOR BUSTLE LIGHT INOP AT R-1 DOOR DURING DAILY SERVICE AT JED. FOUND BROKEN WIRE AT PIN 15 JUMPER, REPLACED PIN. OPS OK PER 33-51-00. (M)SDR TWRA9778Wire · brokenDURING DAILY SERVICE AT JED, FOUND SEAT MOUNTED EVAC LIGHTS INOP, RIGHT SIDE 'B' ZONE. REPAIRED BAD WIRE AT SEAT 17 HJK OPS CHECK OK, PER MM 33-51-00. (M)SDR TWRA9763Wire · brokenDURING DAILY SERVICE AT JFK, FOUND SEAT 13C SIDE MOUNTED EVAC LIGHT INOP. FOUND BROKEN GROUND WIRE, REPAIRED WIRE. SYSTEM OPS OK. (M)SDR TWRA9744Oil Filter · dirtyTHREE MINUTE INTO CLIMB NR 4 ENGINE LOWER OIL PRESSURE LIGHT ILLUMINATED. RETARDED TO 55 PERCENT N1 BEFORE LT WOULD EXTINGUISH. CHANGED OIL FILTER AND CHECKED OIL BYPASS SWITCH AND LOW OIL PRESS SWITCH. RESERVICED ENGINE ENGINE, RUN CHECKS OK PER 71-00-00 TSDR TWRA9720Light · inoperativeDURING DAILY CHECK, FOUND EMERGENCY CEILING LIGHT INOP AT 36 ABC. REMOVED AND REPLACED EMERGENCY LIGHT. OPS CHECK NORMAL AS PER MM 33-51-00. (M)SDR TWRA9701Receiver · malfunctionDURING CLIMB-OUT, AFTER TAKEOFF CREW SMELLED ELECTRICAL EQUIPMENT BURNING. FLIGHT OFFICER HAD OFF FLAG ON VOR OPENED C/B'S AND SMELL WENT AWAY SUSPECT F/O VOR. INSPECTED PILOT'S OVERHEAD PANEL (P10) AND FLIGHT OFFICERS (P3) PANEL. FOUND NORMAL. INSPECTED VSDR TWRA9702Light · inoperativeDURING DAILY CHECK, FOUND 4R DOOR BUSTLE LIGHT INOP. REMOVED AND REPLACED LIGHT ASSEMBLY PER MM 33-51-00. OPS CHECKED NORMAL. (M)SDR TWRA96382Fire Loop · faultyDURING TAXI, NR 2 ENG 'A' FIRE LOOP WENT TO FAULT. FULL SCALE 'B' LOOP TESTED OK WITH ALL OTHER IND NORM. JUST AFTER V1 NR 2 ENGINE 'B' LOOP WENT TO FULL SCALE FAULT. NR 2 ENG WAS SHUT DOWN AND NR 1 FIRE BOTTLE DISCHARGED. C/B WERE RESET AND ENG FIRE WARNISDR TWRA96388Battery Pack · dischargedDURING 'B' SERVICE, FOUND 'C' ZONE LEFT AND RIGHT SIDE EMERGENCY LIGHT INOP. REMOVED AND REPLACED BATTERY PACK PER MM 33-51-00. OPS CHECKED NORMAL. (M)SDR TWRA96387Battery Pack · dischargedDURING B-CHECK, FOUND EXIT SIGN INOP AT R2 DOOR, L2 DOOR, L3 DOOR. REMOVED AND REPLACED BATTERY PACK. OPS CHECKED NORMAL PER MM 33-51-00. (M)SDR TWRA96386Light Assembly · inoperativeDURING B-CHECK, FOUND CEILING LIGHT INOP AT 'A' ZONE LEFT SIDE, B-ZONE RIGHT SIDE AND LEFT SIDE FORWARD, R1 DOOR AND L1 DOOR. REMOVED AND REPLACED LIGHT ASSEMBLY PER MM 33-51-00. OPS CHECKED NORMAL. (M)SDR TWRA96360Slide · failedDURING TRAINING TEST, 4L MAIN ENTRY DOOR SLIDE FAILED TO DEPLOY CORRECTLY DUE TO ASPIRATOR HOSE 'B' FITTING FAILURE, SLIDE P/N D30440105 S/N 0817. REMOVED AND REPLACED 4L MAIN ENTRY DOOR SLIDE PER MM 25-69-00. OPS CHECK NORMAL. (M)SDR TWRA96359Pin · shearedDURING TRAINING TEST 2R DOOR, DOOR ASSIST BOTTLE DID NOT DEPLOY OR DISCHARGE BOTTLE ON SLIDE DEPLOYMENT OPERATION, CABLE ATTACHMENT PIN SHEARED. RIGHT FUSELAGE TO WING PANEL 192RR SUSTAINED DAMAGE DUE TO SLIDE DEPLOYMENT. REPLACED TRIGGER RETAINING PIN AS PESDR TWRA96296Light · inoperativeDURING DAILY CHECK, FOUND CREW DOOR OVERHEAD EXIT SIGN INOP. REPLACED EMERGENCY LIGHT CREW DOOR EXIT SIGN. OPS CHECKED OK PER MM 33-51-00. (M)SDR TWRA96288Light · inoperativeDURING DAILY CHECK, FOUND 3L OVERWING EXIT LIGHT INOP. REMOVED AND REPLACED 3L OVERWING 'EXIT LIGHT' PER MM 33-51-00 PG 401. OPS CHECKED NORMAL. (M)SDR TWRA96287Battery Pack · dischargedDURING DAILY CHECK, FOUND EXIT SIGN ABOVE ROW 32 HJK INOP. REPLACED BATTERY PACK. OPS CHECKED OK PER MM 33-51-00 PAGE 501. (M)SDR TWRA96267Battery Pack · dischargedDURING DAILY CHECK, FOUND 3R DOOR UPPER EVAC LIGHT OUT. REMOVED AND REPLACED BATTERY PACK. OPS CHECKED OK AS PER MM 33-51-00. (M)SDR TWRA96261Roller Crank · brokenON POST FLIGHT INSPECTION, FOUND L3 DOOR LIGHT ON IN COCKPIT WITH DOOR CLOSED. REMOVED UPPER GATE AND UPPER GATE CONTROL ROD. REMOVED TORQUE TUBE, LOWER GATE CONTROL ROD. REMOVED AND REPLACED LATCH ROLLER CRANKS PER MM 52-11-19. OPS CHECKED NORMAL. RIGGINSDR TWRA96264Wire · brokenDURING DAILY CHECK, FOUND EVAC LIGHT UPPER DECK NEAR FLOOR FORWARD OF CREW SLIDE IS INOPERATIVE. REPAIRED BROKEN WIRE TO LIGHT ASSEMBLY. OPS CHECKED NORMAL PER MM 33-51-00. (M)SDR TWRA96205Bulb · failedDURING DAILY CHECK, FOUND SEAT 45C EVAC LIGHT INOP. REPLACED BULB, OPS CHECK NORMAL PER MM 33-51-00. (M)SDR TWRA96204Connector · looseDURING DAILY CHECK, FOUND L1 MED UPPER BUSTLE EVAC LIGHT INOP. FOUND CANNON PLUG OFF OF BUSTLE. RECONNECTED, OPS CHECK NORMAL PER MM 33-51-00. (M)SDR TWRA96207Terminal · failedDURING DAILY CHECK, FOUND LEFT SIDE STATION 1600 EXTERIOR EMERGENCY LIGHTS INOP. REPLACED TERMINAL. OPS CHECK OK PER MM 33-51-00. (M)SDR TWRA96206Bulb · failedDURING DAILY CHECK, FOUND UPPER DECK CREW DOOR EXIT LIGHT OUT OF SERVICE. RELAMPED, OPS CHECK OK PER MM 33-51-00. (M)SDR TWRA96191Wire · brokenDURING DAILY CHECK, FOUND 30ABC, 40ABC, 58ABC SEAT EVAC LIGHT INOP. REPAIRED BROKEN WIRE UNDER SEAT, OPS CHECK OK PR MM 33-51-00. (M)SDR TWRA96190Bulb · failedDURING DAILY CHECK, FOUND 7ABC SEAT EVAC LGHT INOP. RELAMPED 7ABC. OPS CHECK OK PER MM 33-51-00. (M)SDR TWRA9677Battery Pack · dischargedDURING DAILY SERVICE, FOUND OVERHEAD 'EVAC' LIGHTS IN AREA OF SEAT ROW 32K AND EMERGENCY EXIT SIGN INOPERATIVE. REPLACED BATTERY PACK, OPS CHECK OK. MM 33-51-00. (X)SDR TWRA9676Batt Charger · malfunctionedDURING DAILY SERVICE, FOUND 'EVAC' CEILING LIGHT INOP AJACENT TO SEAT 71C. FOUND BATTERY PACK LOW VOLTS, REPLACED CHARGER, OPS CHECK OK. (M)SDR TWRA9674Fuse · blownDURING DAILY CHECK, FOUND LEFT EXTERIOR 3RD EVAC LIGHT IS INOP. REPLACED FUSE FOR EXTERIOR LIGHT ASSEMBLY. OPS CHECK OK MM 33-51-00. (M)SDR TWRA9648Door · damagedDURING POST-FLIGHT, FLT 112, MAINTENANCE REPRESENTATIVE FOUND RIGHT WING GEAR STRUT DOOR DAMAGED, UPPER STRUT DOOR HINGES INTACT, DOOR BROKEN IN TWO, LOWER STRUT DOOR ROD END BROKEN, DOOR INTACT, MINOR DAMAGE TO GULL DOOR, AFT MID-INBD FLAP DAMAGE FROM DEBRIS.SDR TWRA9552Acm · failedBLOCK TURNBACK, DUE TO SMOKE IN CABIN. UPON RETURNING TO GATE, MAINTENANCE FOUND NR 2 AIR CYCLE MACHINE HAD FAILED. REMOVED AND REPLACED THE NR 2 AIR CYCLE MACHINE, OPS CHECK OK. (M)SDR TWRA9517Eel Bulb · failedON DAILY CHECK, FOUND LEFT SIDE C-ZONE NR 1 CEILING (EMERGENCY LIGHT) INOPERABLE. REPLACED LIGHT BULB, OPS CHECK OK. (W)SDR TWRA9513Support Fitting · corrodedDURING B-SERVICE WHILE INSPECTING 5L MAIN ENTRY DOOR FITTING, FOUND AFT GIRT BAR FITTING CORRODED. REPLACED FITTING AND ATTACHING HARDWARE. INSPECTED PER SB 747-53A2378. (X)SDR TWRA9512Support Fitting · corrodedDURING B-SERVICE, WHILE INSPECTING 2L M.E.D. GIRT BAR FITTING, FOUND TWO STEEL PINS (HIGH LOCK FASTENERS) CORRODED. REPLACED FITTING AND ATTACHING HARDWARE. INSPECTED PER SB 747-53A2378. (X)
Back to N609FF, cancelled Oct 24, 2013