N610FF, cancelled Jul 10, 2012
Service difficulty reports · 53
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N610FF' AND deregistration_id = 'N610FF-2012-07-10' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N610FF' AND deregistration_id = 'N610FF-2012-07-10' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR TWRA0016Wire · inoperativeEGRESS LIGHT INOPERATIVE IN STAIRWAY AND FORWARD GALLEY. FOUND OPEN CIRCUITS IN CONNECTOR AND PLUG FITTINGS, FIXED CONNECTOR AND PLUG PER MM 33-51-00. OPERATIONAL CHECK OK. (M)SDR TWRA0003Light · inoperativeDURING DAILY CHECK D-ZONE, RT EMERGENCY PATH LIGHTS INOPERABLE. FOUND EMERGENCY LIGHT FEEDER SHORTED, REPAIRED SHORT. EMERGENCY LIGHT IN D-ZONE RT SIDE OPERATIONAL CHECK OK PER MM 33-53-00 PG 501. (X)SDR TWRA9926Light · inoperableUPPER DECK EMERGENCY ESCAPE LIGHTS INOPERABLE DURING TEST. REPLACED LIGHT STRIP AT BOTTOM OF STAIRWELL - WDM 33-51-00. (X)SDR TWRA9840Oven · dirtyIN FLIGHT, FLIGHT ATTENDANT REPORTED SMELL OF ELECTRICAL NATURE IN THE MID GALLEY. ALL POWER TURNED OFF AND ITEM TRANSFERRED TO ODI 25587. FROM LOG PAGE 25587 OPERATED ALL OVENS, LIGHTS, AND COFFEE MAKERS. ALL OPERATED NORMAL. NO SMOKE, NO SMELL, NO SPARKSSDR TWRA9834Retract Mech · lack of lubeON GEAR EXTENSION, NOSE GEAR REMAINED IN RETRACTED POSITION WITH DOOR CLOSED WITH ALL MAIN BODY GEAR DOWN AND LOCKED. WHEN GEAR HANDLE WAS RECYCLED TO UP POSITION AND THEN REPOSITIONED TO DOWN, ALL GEAR EXTENDED AND LOCKED DOWN NORMALLY. AIRCRAFT TOWED FROM GSDR TWRA9827Light · shortedON DAILY CHECK, FOUND EMERGENCY LIGHTS IN 'A' ZONE AND UPPER DECK WILL NOT TURN ON WHEN TESTED. REPLACED NR 3 EMERGENCY EXIT LIGHT PACK IN OVERHEAD CENTER OF UPPER DECK AND OVERHEAD ASSY AFT OF P-6 PANEL IN COCKPIT. OPS CHECK NORMAL PER MM 33-51-00. (M)SDR TWRA9826Wire · shortedPRIOR TO DEPARTURE WITH COCKPIT EMERGENCY EXIT SWITCH IN OFF POSITION CABIN EXIT LIGHTS CAME ON ALSO IN ARMED POSITION. REPAIRED SHORTED WIRE AT R3 DOOR, OPS CHECK OK AS PER 33-51-00. (M)SDR TWRA9820Linkage · bindingINBOUND FLT 711, JFK-LAS, NR 3 ENGINE WAS SHUT DOWN IN FLIGHT DUE TO THROTTLE BEING STUCK AT 1.5 POSITION. PERFORMED INSPECTION AS PER 76-11-03, FOUND THROTTLE STIFF, CLEANED AND LUBED, OPS CHECK OK. ON NEXT FLIGHT FOUND THRUST LEVER WOULD NOT RETURN TO IDLESDR TWRA9814Light · inoperativePRIOR TO DEPARTURE, FORWARD OF 'E' ZONE RT SIDE 'E' PATH LIGHT INOP. FOUND RT 'E' ZONE LIGHTS EGRESS CONNECTION TO GALLEY WET, DRIED CONNECTION. OPS CHECK OK PER MM 33-59-00 PAGE 501. (M)SDR TWRA97206Wire · failedDURING B-SERVICE, FOUND EVAC 'E' PATH STRIP AT SPIRAL STAIRCASE INOP. REPAIRED EVAC WIRING PR 33-51-00 WDM. OPS CHECK OK PER MM 33-51-00 PAGE 501. (M)SDR TWRA97205Wire · failedON B-SERVICE, EVAC LIGHT INOP AT TOP OF STAIRWAY UPPER DECK. REPAIRED EVAC WIRING PER 33-51-00 WDM, OPS CHECK OK PER 33-51-00 PAGE 501 MM. (M)SDR TWRA97202Light · looseON INSPECTION, FOUND MID GALLEY FLOOR EGRESS LIGHTING STRIP, RT SIDE ARE SLIPPING UNDER MAT. REMOVED MOISTURE AND SECURED EGRESS LIGHTING STRIP. SECURED STRIP, OPS CHECK OK AS PER 33-51-00 PAGE 501. (M)SDR TWRA97195Battery Charger · inoperativeDURING DAILY CHECK, FOUND R1 DOOR EXIT SIGN INOPERATIVE. REMOVED AND REPLACED R1 DOOR BATTERY PACK CHARGER. OPERATIONAL CHECK NORMAL PR MM 33-50-00. (M)SDR TWRA97194Light · inoperativeDURING DAILY CHECK, FOUND MID GALLEY LIGHT STRIP INOPERATIVE. REMOVED AND REPLACED LIGHT STRIP AT MID GALLEY. OPERATIONAL CHECK NORMAL PER MM 33-50-00. (M)SDR TWRA97184Light · inoperativeDURING DAILY SERVICE, FOUND 'A' ZONE LEFT SIDE EGRESS LIGHT STRIP INOPERATIVE. REPLACED EGRESS LIGHT STRIP. OPERATIONAL CHECK NORMAL PER MM 33-51-00. (M)SDR TWRA97183Light · inoperativeDURING DAILY SERVICE, FOUND 'B' ZONE RIGHT SIDE EGRESS LIGHT STRIP INOPERATIVE. REPLACED FORWARD RIGHT SIDE STRIP, OPERATIONAL CHECK NORMAL PER MM 33-51-00. (M)SDR TWRA97146Wire · brokenDURING DAILY SERVICE, FOUND CEILING EMERGENCY LIGHT BY SEAT 36ABC INOP. REPAIRED BROKEN WIRE AT LIGHT ASSEMBLY. PERFORMED OPERATION CHECK OK PER MM 33-51-00. (M)SDR TWRA97137Power Strip · inoperativeDURING DAILY SERVICE, FOUND EVAC FLOOR STRIP LIGH TINOP, FROM SEAT 51-57 LEFT SIDE. REPLACED SHORT POWER STRIP. OPS CHECKED OK PER MM 33-51-00. (M)SDR TWRA97130Connector · defectiveDURING DAILY SERVICE, FOUND UPPER DECK EVAC LIGHTS (FLOOR MOUNTED INOPERATIVE. REPLACED CONNECTOR. OPS CHECKED OK PER MM 33-51-00. (X)SDR TWRA9793Light · inoperativeDURING DAILY CHECK, FOUND L2 BUSTLE LIGHT INOPERATIVE. REMOVED AND REPLACED BUSTLE LIGHT. OPS CHECKED OK PER MM 33-51-00. (X)SDR TWRA97114Battery Pack · dischargedDURING DAILY CHECK, FOUND U/D EGRESS LIGHT INOPERATIVE. REPLACED UPPER DECK BATTERY SUPPLY PACK. OPS CHECKED OK PER MM 33-51-00. (X)SDR TWRA9795Actuator · defectiveIN FLIGHT RUDDER RATIO LIGHT ILLUMINATED AT ALL SPEEDS AND ALTITUDES INTERMITTENTLY. REMOVED AND REPLACED UPPER RUDDER RATION ACTUATOR. OPS CHECKS OK PER MM 27-21-12. (M)SDR TWRA9788Light · inoperativeDURING FLIGHT ENGINEER'S PRE-FLIGHT, STAIRCASE FLOOR PATH EMERGENCY ESCAPE LIGHTS FOUND INOPERATIVE. REPLACED PATH LIGHT STRIP PER MM 33-51-00. OPS CHECKS GOOD (5-5-97). (X)SDR TWRA9741Wire Harness · damagedL-4 EMERGENCY LIGHT HARNESS CRIMPED IN DOOR DURING MAINTENANCE. REPLACED HARNESS. (M)SDR TWRA9740Wire · shortedAFT EMERGENCY LIGHT, CHARGE CONTROLLER C/B IS POPPING DURING MAINTENANCE. REPAIRED SHORTED WIRE AT L-4 DOOR. (M)SDR TWRA9734Lights · inoperative'D' ZONE RT AISLE, FLOOR EVAC LIGHT INOP. MID LAV CROSSWAY, FLOOR EVAC LIGHT INOP. 4L DOOR, UPPER DOOR BUSTLE LIGHT INOP. REPAIRED LIGHTS OPERATIONS CHECKED GOOD. (M)SDR TWRA9728Battery · dischargedFLOOR MOUNTED EVAC STRIP INOP AT 50 ABC TO 57 ABC. REPLACED BATTERY. OPS CHECK OK. (M)SDR TWRA9729Battery · dischargedEXIT SIGN (OVERHEAD) D-ZONE, FT LEFT SIDE, INOP. REPLACED BATTERY PACKAGE, OPS CHECK OK PER 33-51-00. (M)SDR TWRA9719Battery Pack · dischargedDURING DAILY CHECK, FOUND SEAT ROW 27C TO 32C FLOOR EMERGENCY LIGHTS ARE INOP. REPLACED BATTERY PACK. OPS CHECK OK PER MM 33-51-00. (M)SDR TWRA9718Power Supply · inoperativeDURING DAILY CHECK, FOUND LEFT SIDE OVERWING EMERGENCY LIGHTS NR 3 AND NR 4 ARE INOP. REMOVED AND REPLACED POWER SUPPLY. OPS CHECK NORMAL PER MM 33-51-00. (M)SDR TWRA9716Battery Pack · dischargedEXIT SIGNS INOP AT R/2-L/3 MED. REMOVED AND REPLACED BATTERY PACK, PER MM 33-51-00. OPS CHECKED NORMAL. (M)SDR TWRA96340Light · inoperativeR4 MED EMERGENCY BUSTLE LIGHT INOP. REPLACED EMERGENCY BUSTLE LIGHT ON R4 MED. OPS CHECK OK PER MM 33-51-00 PAGE 501. (M)SDR TWRA96339Light · inoperativeREAR GALLEY EMERGENCY FLOOR STRIP INOP. REPLACED REAR GALLEY FLOOR STRIP. OPS CHECK OK PER 33-51-01. (M)SDR TWRA96336Battery · dischargedMAIN CABIN CROSSOVER EXIT, EMERGENCY EVAC LIGHT INOP. IN C-ZONE, FORWARD RIGHT SIDE. REPLACED LIGHT ASSEMBLY BATTERY PACK. OPS CHECK NORMAL PER 33-51-00. (M)SDR TWRA96335Light · inoperativeNR 1 LEFT AND NR 4 LEFT MED UPPER BUSTLE EMERGENCY EVAC LIGHTS INOP REPLACE FAULTY BUSTLE LIGHTS. OPS CHECK OK PER MM 33-51-00. (M)SDR TWRA96334Wire · looseEVAC LIGHT STRIP OUT FROM 36 ABC TO 44 ABC AND IN FRONT OF 'L' LAV. CLEANED CONNECTIONS AND SECURED LOOSE WIRE. (M)SDR TWRA96332Battery · dischargedEVAC SYSTEM OVERWING LEFT SIDE. LAST TWO LIGHT ASSEMBLYS HAVE BOTH LIGHTS OUT. REPLACED BATTERY PACK. OPS CHECK OK PER MM 33-51-00. (M)SDR TWRA96331Light · inoperativeDURING DAILY CHECK, FOUND UPPER DECK EVAC FLOOR STRIP INOP. REPLACED EMERGENCY LIGHT STRIP IN UPPER DECK. OPS CHECKED OK PER MM 33-51-00. (M)SDR TWRA96314Wire · brokenDURING DAILY CHECK, FOUND UPPER DECK FLOOR STRIP EVAC LIGHT IS INOP. REPLACED WIRE FROM POWER SOURCE TO EVAC STRIP. OPS CHECKED NORMAL PER MM 33-59-00. (M)SDR TWRA96226Lights · inoperativeDURING DAILY CHECK, FOUND EMERGENCY OVERWING LIGHTS INOP, (BOTH SIDES). REPAIRED WIRES, OPS CHECKED GOOD PER MM 33-51-00. (M)SDR TWRA96225Wire · brokenDURING DAILY CHECK, FOUND R1 MED EMERGENCY LIGHT INOP. REPAIRED WIRE, OPS CHECKED GOOD PER MM 33-51-00. (M)SDR TWRA96224Strip · inoperativeDURING DAILY CHECK, FOUND C-ZONE EMERGENCY LIGHT (R/S) INOP. REPLACED B-ZONE GALLEY STRIP. OPS CHECKED NORMAL PER MM 33-51-00. (M)SDR TWRA96223Wire · brokenDURING DAILY CHECK, FOUND 5L MED EMERGENCY LIGHT INOP. REPAIRED WIRING. OPS CHECKED OK PER IAW 33-51-00. (M)SDR TWRA9621Girt Bar · stuckAT DEPARTURE L-3 DOOR WOULD NOT GO INTO AUTOMATIC POSITION. INVESTIGATION FOUND GIRT BAR HANGING UP. GIRT BAR WAS FREED. OPS CHECK, IAW MM 52-10-00. (M)SDR TWRA9614Strip Light · brokenDURING GROUND CHECKS, FOUND SEVERAL EMERGENCY LIGHTS INOP. FOUND STRIP LIGHT WIRE BROKEN. TROUBLESHOT AND CORRECTED INOP EMERGENCY LIGHTS. 1 REPLACED 2 SECTIONS OF STRIP LIGHT. (M)SDR TWRA9613Battery Pack · dischargedDURING GROUND CHECKS, FOUND SEVERAL EMERGENCY LIGHTS INOP. FOUND WATER UNDER GALLEY MAT, TROUBLESHOT AND CORRECTED INOP EMERGENCY LIGHTS. REPLACED BATTERY PACK, EMERGENCY CEILING LIGHT ABOVE ROW 59HJK. (M)SDR TWRA9612Lock Assy · missingL-5 DOOR, PRIOR TO DEPARTURE MIA, FOUND GIRT BAR SLIDE BRACKET MISSING (LOCK ASSY). MAINTENANCE INSTALLED NEW SLIDE BRACKET. (X)SDR TWRA9546Eel Wiring Strip · shortedD-ZONE EGRESS LIGHTS RIGHT SIDE INOPERATIVE. REPLACED SHORTED DAMAGED EGRESS STRIP, REPAIRED FLOOR WIRING, OPS CHECK OK. (M)SDR TWRA9545Eel Wire · brokenC-ZONE EGRESS LIGHTS RIGHT SIDE INOPERATIVE. REPLACED BROKEN GROUND WIRE AT BATTERY PACK, OPS CHECK OK (M)SDR TWRA9544Eel Wire · shortedUPPER DECK EGRESS LIGHTS AT SEATS AND COCKPIT INOPERATIVE. REPLACED SHORTED EGRESS FEED. REPLACED WIRING TO EXIT EGRESS SIGN IN COCKPIT. OPS CHECK OK. (M)