N630AE, cancelled Oct 3, 2025
Service difficulty reports · 186
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N630AE' AND deregistration_id = 'N630AE-2025-10-03' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N630AE' AND deregistration_id = 'N630AE-2025-10-03' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2024121201226Oxygen Mask · unwanted deployCLIMBING THRU 18K IN LIGHT TO MODERATE TURBULANCE. AFTER LEVELING OFF, FA REPORTED ALL PAX O2 MASKS WERE DEPLOYED FACT 11DEC24 12:07 CLT REPACKED ALL O2 MASKS IAW AMM 35-20-04 A/C OK FOR SERVICESDR HNAA2024120901168Control Panel · faultedBLEED #2 VALVE CLOSED MIDAIR FACT 08DEC24 02:24 PHL R&R PNEUMATIC CONTROL PANEL IRW AMM 20-13-10.OPS CHECKED IRW AMM 36-00-00 AND AMM 21-00-00. OPS CHECK GOOD. OK FOR SERVICE AT THIS TIME.SDR HNAA2024112001102Fuel Sys · out of balanceDURING CRUISE GOT FUEL EMBALANCE WARNING WITH TANK 1 GOING TO 0 ON EICAS AND MFD. ISSUE SELF CLEARED AFTER 4-5 MINS. DURING EVENT LOSS OF #1 FUEL FLOW AND FUEL USED INDICATIONS WAS NOTED TOO. FACT 19NOV24 15:23 CLT UNABLE TO DUPLICATE, R&R'D FUEL CONDITIONSDR HNAA2024112001002Fuel Sys · out of balanceDURING CRUISE GOT FUEL EMBALANCE WARNING WITH TANK 1 GOING TO 0 ON EICAS AND MFD. ISSUE SELF CLEARED AFTER 4-5 MINS. DURING EVENT LOSS OF #1 FUEL FLOW AND FUEL USED INDICATIONS WAS NOTED TOO. FACT 19NOV24 15:23 CLT UNABLE TO DUPLICATE, R&R'D FUEL CONDITIONISDR HNAA2024012500035Skin Panel · corrodedSKIN PANEL 145-35010-003 HAS CORROSION. R&R'D IAW EO1-53-24-0043SDR HNAA2024012500034Rivet · pulled3 PULLED RIVETS HAVE CORROSION AT FR67 STR20R. R&R'D PANEL IAW EO1-53-24-0043SDR HNAA2024012500033Rivet · pulled2 PULLED RIVETS HAVE CORROSSION AT FR68 STR21L. R&R'D PANEL IAW EO1-53-24-0043SDR HNAA2023092200345Unknown · unknownFUEL SMELL IN CABIN IN CRUISE. GROUND RAN A/C AT VARIOUS POWER SETTINGS WITH AND WITHOUT PACKS. NO FUEL SMELL NOTED. A/C OKAY FOR SERVICE.SDR HNAA2023091200330Unknown · unknownAFTER GEAR RETRACTION 3 NORMAL INDICATIONS SHOWED. SHORTLY AFTER R/H MLG CYCLED TO LOCKED / UNLOCKED POSITION CONTINUOUSLY.........JACKED AND SWUNG GEAR ISSUE WAS VISIBLE ALSO ASSOSIATED WITH HYD THUMPING. R&R'D R/H MLG UPLOCK BOX IN REF TO AMM 32-33-10-000/40SDR HNAA2023052200176Unknown · unknownON TAKEOFF ROLL FUEL 2 LOW LEVEL CAUTION/WARNING DISPLAYED. ON TAXI BACK FUEL 2 LOW LEVEL WARNING DISPLAYED AND FUEL QTY 1 SHOWED DASHES. AT GATE FUEL IMBALANCE EICAS AND QTY FOR THE NO.1 TANK SHOWS 0. AFTER SLAVING IN NEW FCU MESSAGE CLEARED ONCE ORIGINAL FSDR HNAA2022071800242None · noneE922505 - LH PYLON SPAR 2 YOKE FASTENER HOLE THROUGH UPPER SKIN GOUGED. .... ACCOMPLISHED REPAIR OF LH PYLON SPAR 2 YOKE FASTENER HOLE IAW EMB SB# 145-54-0008 AND EO1-54-22-0141.SDR HNAA2022071800241None · noneE922303 - FRAME 67 IS CRACKED AT CARGO DOOR SILL .... REMOVED AND REPLACED FRAME 67 (LOWER FRAME SECTION) AT CARGO DOOR SILL IAW EMB145 SRM 51-40-02.SDR HNAA2022071800239None · noneE920591 - PILOT BULKHEAD UPPER OTBD GUIDE PIN HOLE IS GOUGED .... ACCOMPLISHED REPAIR AT PILOT BULKHEAD UPPER OTBD GUIDE PIN HOLE IAW EMB 145 SRM 53-21-02 RE SECTION 4 AND EO1-53-22-0140.SDR HNAA2022071800233None · noneE920263 - CARGO DOOR LOWER SILL IS CORRODED. .... REMOVED AND REPLACED CARGO DOOR LOWER SILL IAW EMB 145 SRM 51-40-02SDR HNAA2022071800232None · noneE919773 - BAGGAGE DOOR UPPER AFT FRAME IS GOUGED AROUND NUTPLATE HOLE .... REPAIRED BAGGAGE DOOR UPPER AFT FRAME GOUGE AROUND NUTPLATE HOLE IAW PIEDMONT EO1-52-22-0139SDR HNAA2022071800238None · noneE920543 - CORROSION ON DIAMOND GUSSET AT FRAME 22 GALLEY AREA .... REMOVED AND REPLACED DIAMOND GUSSET AT FRAME 22 GALLEY AREA IAW EMB 145 SRM 51-40-02SDR HNAA2022071800237None · noneE920541 - CORROSION ON FLOOR CROSS BEAM AT FRAME 20 GALLEY AREA .... REMOVED AND REPLACED FLOOR CROSS BEAM AT FRAME 20 GALLEY AREA.IAW EMB145 SRM 51-40-02.SDR HNAA2022071800240None · noneE920658 - CABIN CENTER AISLE FLOOR CROSSBEAM AT FR 25 CORRODED .... REMOVED CORRODED CABIN CENTER AISLE FLOOR CROSSBEAM AT FR 25 AND INSTALLED SERVICEABLE CROSSBEAM IAW EMB 145 SRM 51-40-02.SDR HNAA2022071800234Frame · crackedE920281 - FR 72 IS CRACKED BTW STR 17L-16L .... REMOVED AND REPLACED FR 72 BTW STR 15L-14R. IAW EMB 145 SRM 51-40-02SDR HNAA2022071800236None · noneE920360 - LAV CENTER BEAM GUSSET IS CORRODED AROUND FWD AND AFT SCREW HOLES .... REMOVED AND REPLACED LAV CENTER BEAM GUSSET IAW EMB 145 SRM 51-40-02SDR HNAA2022071800235Gusset · corrodedE920357 - LAV LH BEAM GUSSET IS CORRODED AROUND FWD AND AFT SCREW HOLES .... REMOVED AND REPLACED LAV LH BEAM GUSSET IAW EMB 145 SRM 51-40-02SDR HNAA2022010500046Unknown · odorPREVIOUS CREW REPORTS OF BURNING SMELL IN FLIGHT DECK, CREW DID NOT REPORT TO MOCC. GROUND RAN A/C W/ #1 AND #2 ENG BLEED AND APU BLEED FOR 40 MIN W/ REF TO AMM 21-51-00-700-802-A. OPS CHECK GOOD. NO BURNING SMELLS NOTED AT THIS TIME. OK FOR SERVICE.SDR HNAA2021080200350Control Unit · malfunctionedPITCH TRIM MAIN INOP. R+R HSCU IRW EMB 145 AMM 27-40-01. OPS CHECK GOOD(MX CTRL NOTE: HSCU WAS CHANGED AS A PRECAUTION. FIM TASK 27-43-00-810-801-A WAS FOLLOWED TO BLOCK 7 WHICH DETERMINED AS A TRANSITORY CONDITION.)SDR HNAA2020122800378Switch · handler errorEICAS DISPLAYED E1 FUEL LOW LEVEL COUPLED WITH DASHED FUEL QUANTITIES ON MFD AND EICAS. UPON INSPECTION FOUND REFUEL SWITCH ON SPR PANEL TO BE IN OPEN POSITION. INSP SPR PANEL AND PERFORMED FUEL QUNTY OPERATIONAL CHECK, IAW 28-41-00, NO DEFECTS NOTED. ALL ISDR HNAA2020072000196Light · damagedLEFT EXTERIOR EMERGENCY LIGHT ABOVE WING BELOW DOOR INOPERATIVE. R & R THE LEFT EXTERIOR EMERGENCY LIGHT ABOVE WING. FURTHER INSPECTION FOUND BAD NUT PLATES. R & R THE EMERGENCY LIGHT ASSEMBLY IAW AMM 33-50-10-000/400-801A. OP CHECKED GOOD, OK FOR SERVICE.SDR HNAA2019122400390Warning Message · false activationREJECTED TAKEOFF AT 5 KNOTS DUE TO A MOMENTARY NOSE WHEEL STEERING INOPERATIVE MESSAGE. CREW RESET NOSE WHEEL STEERING AND DEPARTED, NO MAINTENANCE ACTION.SDR HNAA2019102200319Connector · brokenABI - BROKEN WIRE CONNECTOR FOR EMERGENCY LIGHT STRIP #8 .... REPAIRED WIRE CONNECTOR FOR
EMERGENCY LIGHT STRIP #8 IAW EMB 145 SW-PM 20-21-00SDR HNAA2019102200318Wire · chafedABI - FLOOR EMERGENCY LIGHT WIRE IS CHAFED AT FRAME 20. REPAIRED FLOOR EMERGENCY LIGHT WIRE T FRAME 20 IAW EMB 145 SWPM 20·21 ·00SDR HNAA2019061100169Fire Warning · illuminatedRECEIVED A BAGGAGE SMOKE INDICATION AFTER TAKE OFF,CREW PUSHED BAGG EXTINGUISHING BUTTON. R & R BAGGAGE BAY FIRE EXT. BOTTLES,HRD & METERING BOTTLES IAW AMM 26-23-01. ON LANDING FIRE TRUCK ROLLED ON, MET A/C. NO O2 MASKS DOWNED OR CALL FOR PAX BRACE. A/C TSDR HNAA2019052200148Acm · malfunctionedPDIS 630 21-01 2097683 20MAY19 GSO CLOSE IN CRUISE FLIGHT AT 25K BOTH FLIGHT DECK AND CABIN EXPERIENCED LIGHT SMOKE. C/W QRH PROCEDURE AND SMOKE DISSIPATED 24934 00 EK HISTORY: FACT 21MAY19 12:02 GSO R&R NR 1 AIR CYCLE MACHIINE IAW 21-51-03. OPSDR HNAA2019040900092Fire Warning · false activationPDIS 630 26-15 2055741 07APR19 PHL CLOSE
ON TAXI OUT MASTER WARNING TRIPLE CHIME EICAS MESSAGE BAG SMOKE. FIRE EXTINGUSHER BAG BUTTON ILLUMINATED
.CREW PERFORMED MEMORY ITEMS (RELEASED EXTIG AGENT)RAN QRH FA PERFORMED VISUAL INSPECTION.FSDR HNAA2018111300283Smoke Detector · false indicationFOLLOW UP ACTION:
NDIS 630 26-10 0014510 12NOV18 SBY CLOSE
F/U TO LAV SMOKE DETECTOR EICAS MESSAGE DISPLAYING
FACT 12NOV18 10:39 SBY
R & R'D LAV SMOKE DETECTOR IAW AMM TASK 26-14-01-
(000/400)-801-ASDR HNAA2018111300282Smoke Detector · false activationPDIS 630 26-23 1660181 12NOV18 CLT CLOSE
LAV SMOKE EICAS MESSAGE DISPLAYED ENROUTE. CBS E12
AND E13 PULLED PER QRH
FACT 12NOV18 18:11 CLT
INSP. AND TESTED LAV SMOKE DET. NO DEFECTS NOTED. GROUND RAN A/C WITH PACKS 1&2 OSDR HNAA2018111300281Flashlight · odor630 26-23 1660162 10NOV18 PHL CLOSE
DURING INITIAL CLIMBOUT RECEIVED LAV SMOKE AURAL WAR
NING AND LAV SMOKE EICAS MSG.
FACT 10NOV18 18:48 PHL
DETERMINED SOURCE OF SMELL WAS AFT FA'S FLASH LIGHT.
R&R'D FLASH SDR HNAA2018100300240Unknown · malfunctionedPDIS 630 34-41 1674792 02OCT18 PHL CLOSE RADAR FAILED IN FLIGHT. 39524 00 LLS FACT 02OCT18 16:06 PHL PERFORMED RADAR OPS CHECK, TEST PASSED. NO DEFECTS NOTED AT THIS TIME, REF AMM 34-42-00-05. OK FOR SERVICE.SDR HNAA2018081000186Smoke Warning · false activationCARGO SMOKE INDICATION ON EICAS IN FLIGHT, IMMEDIATELY EXTINGUISHED, THE FIRE EXTG CARGO BUTTON REMAINED ILLUMINATED, EXTINGUISHED WITH FIRE TEST ON GROUND. PERFORMED AN OPS CHECK OF THE CARGO SMOKE INDICATION SYSTEM IAW AMM 26-15-00, OPS CHECK GOOD. OKSDR HNAA2018071100143Warning System · activatedE2 FIRE DETECT FAIL MSG DURING FLT.SDR HNAA2018061200121Inverter · inoperativeEMERGENCY LIGHT WAS INOPERATIVE ABOVE THE GALLEY EXIT. R & R THE EMERGENCY LIGHT INVERTER.SDR HNAA20180521001Light · inoperativeFLOOR EMERGENCY LIGHT INOPERATIVE BY THE EMERGENCY EXIT DOOR. R & R EMERGENCY LIGHT IAW AMM 33-50-12. OPS CHECKED GOOD.SDR HNAA2017122700401Light · contaminatedRIGHT LOWER EMERGENCY LIGHT HAS MOISTURE INSIDE OF THE LENS. REMOVED, CLEANED MOISTURE AND REINSTALLED IAW AMM 33-50-10-000/400-801-A. OK FOR SERVICE.SDR HNAA2017111700375Control Unit · brokenPITCH TRIM MAIN INOP EICAS WARNING MESSAGE. REPAIRED BROKEN WIRE UNDER TRIM CNLT PNL, NO FIX. R&R HOZ STAB CNTL UNIT OPS CK GOOD IAW AMM 27.40.01.00.801.A AND 27.40.00.400.801.A. ACFT OK FOR SERVICE.SDR HNAA2017092900340Unknown · noisePILOT REPORTED A LOUD NOISE SIMILAR TO WHATS HEARD DURING GEAR EXTENSION. NO GEAR INDICATION ANOMALIES. NOISE WENT AWAY AFTER FEELING MECHANICAL THUMP BELOW PILOTS FEET. PERFORMED GEAR EXTENSION AND RETRACTION, OPS CHECKED GOOD.SDR HNAA2017062100211Flap System · malfunctionedDURING TAKE OFF, CONFIGURATION CHECK FLAPS WARNING AURAL MESSAGE WAS HEARD. POWERED DOWN AND POWERED UP AIRCRAFT, CYCLED CIRCUIT BREAKERS F16, F19, AND FLAPS RESET SWITCH ON MAINTENANCE PANEL. ACCOMPLISHED TASK 27-53-00-700-802A, OPS CHECKED GOOD, OK FOR SESDR HNAA2017051200167Circuit Breaker · malfunctionedELECTRIC HYD PUMP NR 2 CIRCUIT BREAKER FOUND TRIPPED. STRONG ELECTRICAL ODOR WHEN MAINT RESET THE CIRCUIT BREAKER. CIRCUIT BREAKER PULLED. TRIPPED AGAIN WHEN POWER APPLIED. INSPECTED UNDER COCKPIT FLOOR. NO ODOR OR DEFECTS NOTED. POWERED ACFT DOWN AND BSDR HNAA2017050400147Smoke Detector · false indicationCARGO SMOKE WARNING LIGHT APPEARED ON EICAS WITH ASSOCIATED EXTINGUISHER CARGO OVERHEAD BUTTON LIGHT. INSPECTED BAGGAGE COMP FOR EVIDENCE OF SMOKE OR FIRE, NO DEFECTS NOTED PERFORMED A VISUAL INSPECTION OF CARGO SMOKE DETECTORS IAW 26-15-01 AND BAGGAGE BAY SSDR SIMA20170414008Floor Support · crackedCOCKPIT FLOOR SUPPORT CRACKED UNDER 221GF. PERFORMED PERMANENT REPAIR OF COCKPIT FLOOR SUPPORT CRACKED UNDER 221GF IAW ERS-EM-53MR-2680.SDR SIMA20170414006Spar · crackedLT WING SPAR I LEADING EDGE LOWER ATTACHMENT FLANGE IS CRACKED AT RIB 9. REPAIRED LT WING SPAR I LEADING EDGE LOWER ATTACHMENT FLANGE AT RIB 9 IAW ERS-EM-57MR-799.SDR SIMA20170414005Stringer · corrodedCORROSION IN CABIN ON STR 21L BETWEEN FRAMES 30 AND 31. ACCOMPLISHED PERMANENT REPAIR CORROSION IN CABIN ON STR 21L BETWEEN FRAMES 30 AND 31 IAW ERS-EM-53MR-2673.SDR SIMA20170408004Frame · crackedFR 73 CRACKED BTW STR 16R-17R (BELOW CARGO BULKHEAD SUPPORT BEAM). PERFORMED PERMANENT REPAIR OF FR 73 CRACKED BTW STR 16R-17R IAW SRM 51-40-02.SDR SIMA20170407006Floor Support · corrodedCORROSION ON LT OMEGA BEAM BETWEEN FRAMES 58-59. REMOVED AND REPLACED LT OMEGA BEAM IAW SRM 51-40-02 AND SRM 51-20-01.